Page 66 of 195 ![]() |
![]() View extracted text
Page 66 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie67 Shearwall STRONG-WALL SHEARWALL The building designer shall verify that these details are consistent with the complete load path requirements of the structure. 1. For plywood shear panel, add P to model name (e.g. SW24x8P), and multiply loads by 0.88. 2. For two-pour applications, use the SSTB34. 3. Recommended header moisture content is 19% or less at time of installation. 4. A single wall garage portal system consists of 1 wall with a header spanning over the top and connected as shown. 5. Recommended minimum 5/8"x12" mudsill anchor. 6. The minimum header sizes listed are the minimum required for lateral rigidity of the portal system. Larger headers may be required due to vertical loading. 7. Portal walls may be installed with sheathing facing inside or outside. 8. Maximum shim height between Strong-Wall Portal Walls and header is ". Shims of greater thickness will result in load reductions. 9. See allowable vertical load table on page 64 for Strong-Wall maximum compression and tension capacities. 10.Capacities must be reduced as limited by anchor bolt capacities for installations on CMU. Model No. W (in) H (in) T (in) Number of Fasteners in Top of Wall Number of Mudsill Anchors 5 Holdown 2 Anchor Bolts Allowable Shear V Load (lbs) for Portal System Drift at Allowable Shear V (in) Allowable Shear V Load (lb/ft) Wall Code Ref. Weight (lbs) SW16x7x4 16 78 4 8-SDS x6 2- 2-SSTB28 1460 .348 1095 90 SW16x7x6 16 78 5 8-SDS x6 2- 2-SSTB28 1460 .348 1095 112 SW16x8x4 16 90 4 8-SDS x6 2- 2-SSTB28 1245 .420 935 95 SW16x8x6 16 90 5 8-SDS x6 2- 2-SSTB28 1245 .420 935 120 SW22x7x4 22 78 4 10-SDS x6 2- 2-SSTB28 2190 .396 1195 95 SW22x7x6 22 78 5 10-SDS x6 2- 2-SSTB28 2190 .396 1195 117 SW22x8x4 22 90 4 10-SDS x6 2- 2-SSTB28 1995 .446 1090 105 SW22x8x6 22 90 5 10-SDS x6 2- 2-SSTB28 1995 .446 1090 130 34, 101 SINGLE WALL GARAGE PORTAL 4 Detail 2 Single and Double Wall Garage Portal 1. Beam to support post and support post to foundation uplift connectors may be reduced where justified by calculations. 2. This detail reflects lateral load requirements of a Single and Double Wall Portal system. It is the designers responsibility to provide a complete load path for all loads in accordance with the governing codes. 3. System rating equals the sum of the Single and Double Wall Portal values. 4. Alternate Installation: A single piece header (no camber) may be substituted for the two headers shown. The design rating for this condition may then be evaluated as the sum of the individual wall (pier) ratings. Individual wall (pier) ratings for this condition may be taken as half of their Double Wall Portal values. 5. Longer header spans can be accommodated if larger headers are used such that equivalent stiffness is equal to or greater than that provided by the minimum header and maximum length indicated. 6. LTP4 and LSTA24 (design by others) are minimum requirements to achieve the allowable loads. CODES: See page 12 for Code Listing Key Chart. Detail 1 Single Wall Garage Portal 1. Beam to support post and support post to foundation uplift connectors may be reduced where justified by calculations. 2. This detail reflects lateral load requirements of a Single Wall Portal system. It is the designers responsibility to provide a complete load path for all loads in accordance with the governing codes. 3. Longer header spans can be accommodated if larger headers are used such that equivalent stiffness is equal to or greater than that provided by the minimum header and maximum length indicated. 4. STHD10 and LSTA24 (design by others) are minimum requirements to achieve the allowable loads.[close] |
Page 66 of 195 ![]() |
All Copyrights are and remain property of Simpson Strong-Tie. Who-sells-it.com is not an official partner of Simpson Strong-Tie. |