Shearwall
STRONG-WALL SHEARWALL
The building designer shall verify that these details are consistent with the complete load path requirements of the structure.
1. For plywood shear panel, add P to model name (e.g. SW24x8P), and
multiply loads by 0.88.
2. For two-pour applications, use the SSTB34.
3. Recommended header moisture content is 19% or less at time of installation.
4. A single wall garage portal system consists of 1 wall with a header spanning
over the top and connected as shown.
5. Recommended minimum 5/8"x12" mudsill anchor.
6. The minimum header sizes listed are the minimum required for lateral rigidity
of the portal system. Larger headers may be required due to vertical loading.
7. Portal walls may be installed with sheathing facing inside or outside.
8. Maximum shim height between Strong-Wall Portal Walls and header is ".
Shims of greater thickness will result in load reductions.
9. See allowable vertical load table on page 64 for Strong-Wall maximum
compression and tension capacities.
10.Capacities must be reduced as limited by anchor bolt capacities for installations on CMU.
Model
No.
W
(in)
H
(in)
T
(in)
Number of
Fasteners in
Top of Wall
Number of
Mudsill
Anchors 5
Holdown 2
Anchor Bolts
Allowable Shear
V Load (lbs)
for Portal
System
Drift at
Allowable
Shear V
(in)
Allowable
Shear V
Load
(lb/ft)
Wall
Code
Ref.
Weight
(lbs)
SW16x7x4
16
78
4
8-SDS x6
2-
2-SSTB28
1460
.348
1095
90
SW16x7x6
16
78
5
8-SDS x6
2-
2-SSTB28
1460
.348
1095
112
SW16x8x4
16
90
4
8-SDS x6
2-
2-SSTB28
1245
.420
935
95
SW16x8x6
16
90
5
8-SDS x6
2-
2-SSTB28
1245
.420
935
120
SW22x7x4
22
78
4
10-SDS x6
2-
2-SSTB28
2190
.396
1195
95
SW22x7x6
22
78
5
10-SDS x6
2-
2-SSTB28
2190
.396
1195
117
SW22x8x4
22
90
4
10-SDS x6
2-
2-SSTB28
1995
.446
1090
105
SW22x8x6
22
90
5
10-SDS x6
2-
2-SSTB28
1995
.446
1090
130
34, 101
SINGLE WALL GARAGE PORTAL 4
Detail 2 Single and Double Wall Garage Portal
1. Beam to support post and support post to
foundation uplift connectors may be reduced
where justified by calculations.
2. This detail reflects lateral load requirements
of a Single and Double Wall Portal system.
It is the designers responsibility to provide
a complete load path for all loads in
accordance with the governing codes.
3. System rating equals the sum of the Single
and Double Wall Portal values.
4. Alternate Installation: A single piece header
(no camber) may be substituted for the two
headers shown. The design rating for this
condition may then be evaluated as the sum
of the individual wall (pier) ratings. Individual
wall (pier) ratings for this condition may be
taken as half of their Double Wall Portal values.
5. Longer header spans can be accommodated if
larger headers are used such that equivalent
stiffness is equal to or greater than that
provided by the minimum header and
maximum length indicated.
6. LTP4 and LSTA24 (design by others) are
minimum requirements to achieve the
allowable loads.
CODES: See page 12 for Code Listing Key Chart.
Detail 1 Single Wall Garage Portal
1. Beam to support post and support post to foundation uplift connectors
may be reduced where justified by calculations.
2. This detail reflects lateral load requirements of a Single Wall Portal system.
It is the designers responsibility to provide a complete load path for all
loads in accordance with the governing codes.
3. Longer header spans can be accommodated if larger headers are used
such that equivalent stiffness is equal to or greater than that provided by
the minimum header and maximum length indicated.
4. STHD10 and LSTA24 (design by others) are minimum requirements to
achieve the allowable loads.
[close]