Page 68 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
69
Solid Sawn Connectors
LUS/HUS Double Shear Joist Hangers
LOAD TABLE EXPLANATION
This product is preferable to similar connectors because of a) easier installation,
b) higher loads, c) lower installed cost, or a combination of these features.
See Hanger tables on pages 70 to 76. See Hanger Options on pages 188
for hanger modifications, which may result in reduced loads.
All hangers in this series have double shear nailing. This patented innovation
distributes the load through two points on each joist nail for greater strength. It
also allows the use of fewer nails, faster installation, and the use of standard nails
for all connections. (Do not bend or remove tabs.)
MATERIAL: See tables, pages 70 to76.
FINISH: Galvanized. Some products available in stainless steel or Z-MAX;
see Corrosion-Resistance, page 6-7. Stainless steel (SS) hangers are
available with SS nails-order LUS210-2SSN.
INSTALLATION Use all specified fasteners. See General Notes.
Nails must be driven at an angle through the joist or truss into the header
to achieve the table loads.
Not designed for welded or nailer applications.
16d sinkers (0.148" dia. x 3 long) may be used where 10d commons
are specified with no reduction in load. Where 16d commons are specified,
10d commons or 16d sinkers (0.148" dia. x 3 long) may be used at
0.85 of the table load.
With 3x carrying members, use 16d x 2 nails into the header and
16d commons into the joist with no load reduction. With 2x carrying
members, use 10d x 1 nails into the header and 10d commons into
the joist, reduce the load to 0.64 of the table value. Use stainless steel (SS) nails with SS hangers.
OPTIONS: LUS hangers cannot be modified.
HUS hangers available with the header flanges turned in for 2-2x (3 and
4x only, with no load reduction. See the HUSC Concealed Flange illustration.
See Hanger Options, page 188.
HUSC
Concealed Flanges
(not available for HHUS,
HGUS and HUS2x)
LUS28
HUS210
(HUS26, HUS28,
and HHUS similar)
HUS412
Double
Shear
Nailing
Top View
Typical LUS28 Installation
use .148x3" (10d common)
or .148x3 (16d sinker) nail
B
Dome Double Shear
Nailing Side View
(available on
some models)
U.S. Patent 5,603,580
Double
Shear
Nailing
Side View
Joist
Size
Model
No.
Ga
Dimensions
Fasteners
Doug Fir Larch/Southern Pine Allowable Loads
W
H
B
Header
Joist
Uplift
Floor (100)
Snow (115)
Roof (125)
10d
16d
(133)
(160)
10d
16d
10d
16d
10d
16d
ROUGH LUMBER SIZES
2x4(R)
LU24R-18
18
2
3
1
4-16d
2-10dx1
U24R
16
2
3
2
4-10d
4-16d
2-10dx1
240
265
445
530
510
610
555
665
2x6(R)
LU26R-18
18
2
4
1
6-16d
4-10dx1
U26R
16
2
5
2
8-10d 8-16d
4-10dx1
480
575
890
1065
1020
1225
1110
1330
Code
Ref.
170
26, 121
170
26, 121
245
265
530
610
665
490
565
800
920
1000
OTHER CATALOG DEFINITIONS
Deflection: The distance
a point moves when a load
is applied.
NAILS: 16d 0.162" dia. x 3 long,
10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
Allowable Design Loads: The maximum load
that a connection is designed to provide.
There may be multiple design loads acting
in different directions (up, down, lateral,
perpendicular, etc.) imposed on a connection.
Model No.: This is the
Simpson product name.
Joist Size:
This shows
the size of
joist member.
Gauge: Product material
Uplift
Floor, Snow, Roof
Dimensions W, H, B: This
shows the product dimensions
(width, height and base in this
case.) The product drawing
includes these callouts as a
cross-reference.
Nails: This
shows the fastener
quantity and type
required to
achieve the
table loads.
Code Ref.:
See page 12 for
the Code Listing
Key Chart, to
determine which
code reports
include this
product.
Throughout this catalog a footnote will typically be
provided indicating the required nail diameter and length.
All installations should
be designed only in
accordance with the
allowable load values
set forth in this catalog.
[close]