Page 76 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
77
Solid Sawn Connectors
TOP FLANGE HANGERS JB/LB/BA/B/HHB Joist, Beam and Purlin Hangers
HUTF/HUSTF Heavy Duty and Double Shear Joist Hangers
NAILER TABLE
This table also applies to sloped-seat hangers.
B SERIES WITH VARIOUS HEADER APPLICATIONS
Model
No.
Nailer
Header
Nails
Allowable
Down Loads
DF/SP
LB26
2x
850
LB28
2x
915
LB210
2x
915
LB212
2x
915
LB214
2x
915
LB216
2x
1150
B
2x
4-10dx1
4-10dx1
4-10dx1
4-10dx1
4-10dx1
4-10dx1
10-10dx1
3x
4x
14-16d
14-16d
3800
3725
2-2x
14-10d
BA
14-10d
3615
3x
14-16dx2
14-16dx2
4x
2-2x
3300 1
3230
2695
2220
SPF
2770
2235
1755
1. Uplift loads have been increased 33% and 60% for earthquake or wind loading with no further increase
allowed. Reduce by 33% and 60% for normal loading such as in cantilever construction.
2.Loads may not be increased for short-term loading.
3. Code values are based on DF/SP header species.
4. NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
1. Based on
an additional beyond
the normal deflection
limit.
Model
Series
Top
Allowable Loads Header Type
Fasteners
DF/SP
BA
Min.
6-10dx1
6-10d
6-16d
6-10d
160
26, 83,
124
6-16d
6-10d
B
6-16d
Face
4-10dx1
10-10d
10-16d
10-10d
10-16d
8-10d
8-16d
Joist
2-10dx1
2-10dx1
2-10dx1
8-10dx1
8-10dx1
6-10dx1
6-16dx2
BA
Max.
SPF
Code
Ref.
2425
2665
2465
2665
2190
2650
3080
3435
3625
3800
3625
3800
LVL
PSL
3630
3705
3630
4320
3195
3355
3230
4015
3555
4715
3575
4135
Uplift
(160)
Uplift
(133)
315
315
1170
1170
990
1010
265
265
1055
1055
825
1010
LB
See dimensions, material, loads on table pages.
HUSTF has the double shear nailing advantage
distributing the joist load through two points on each nail
for greater strength.
FINISH: Galvanized. See Corrosion-Resistance, page 6-7.
INSTALLATION:
Use all specified fasteners. See General Notes.
Not acceptable for nailer or welded applications;
see W and B hangers.
HUTF The minimum header or ledger size
that can be used with this hanger is 3 ".
HUSTF With 3x carrying members, use 16dx2
nails into the header and 16d commons into the joist.
OPTIONS:
HUTF Rough beam sizes are available by special order.
See Hanger Options on page 188 for skewed hangers.
Available with flanges turned in (2-2x and 4x only for
HUSCTF. 2 or greater for HUCTF).
Nailer application is NOT
acceptable. Fasteners
cannot be installed
Typical
HUTF
Installation
HUCTF
HUSTF
Some model
configurations may
differ from those
shown. Production
models have
projected seats.
Square cut seats may
be ordered. Consult
factory for details.
Typical BA
Installation
on Wood
Nailer
Typical BD
Saddle Installation
BA
B
(HHB Similar)
Double Shear
Nailing Top View
HU410TF
LB, BA, B and HHB are acceptable for
weld-on applications. See Installation
Information.
JB
The BA hanger is a cost effective hanger featuring min/max joist
nailing option. Min Nailing featuring Positive Angle Nailing targets moderate
load conditions where as the Max Nailing generates capacities for higher loads.
The unique two level embossment provides added stiffness to the top flange.
The newly improved B hanger offers wide versatility with enhanced
load capacities.
See tables on pages 79 to 81. See Hanger Options on pages 188
and 192 for hanger modifications, which may result in reduced loads.
MATERIAL: See tables, pages 79 to 81.
FINISH: JB, LB and B Galvanized; HHB-all saddle hangers and all welded
sloped and special hangers Simpson gray paint.
INSTALLATION: Use specified fasteners. See General Notes and nailer table.
LB, BA, B and HHB may be welded to steel headers with weld size
to match material thickness (approximate thickness shown). The
minimum required weld to the top flanges is x 2" x 1 for LB)
fillet weld to each side of each top flange tab for 14 and 12 gauge and
x 2" fillet weld to each side of each top flange tab for 7 gauge.
Distribute the weld equally on both top flanges. Welding cancels the
top and face nailing requirements. Consult the code for special
considerations when welding galvanized steel. The area should be
well-ventilated (see page 14 for welding information). Weld on
applications produce the maximum allowable down load listed.
Uplift loads do not apply to welded applications.
Ledgers must be evaluated for each application separately. Check TF
dimension, nail length and nail location on ledger.
OPTIONS: B and HHB
Other widths are available; specify W dimension (the minimum
W dimension is 1 for B and 2 for HHB).
B dimensions may be increased on some models.
See Hanger Options, page 188.
CODES: See page 12 for Code Listing Key Chart.