82
This product is preferable to similar connectors because of a) easier installation,
b) higher loads, c) lower installed cost, or a combination of these features.
Solid Sawn Connectors
LSU/LSSU Adjustable Light Slopeable/Skewable U Hangers
This series attach joists or rafters to headers, sloped up or down, and
skewed left or right, up to 45 .
MATERIAL: See table.
FINISH: Galvanized. Some products available in Z-MAX;
see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
Attach the sloped joist at both ends so that the horizontal force
developed by the slope is fully supported by the supporting members.
CODES: See page 12 for Code Listing Key Chart.
STEP 1
Nail hanger to slope-cut
carried member,
installing seat nail first.
No bevel necessary for
skewed installation.
STEP 2
Skew flange to form
acute angle. Bend
other flange back along
centerline of slots.
Bend one time only.
STEP 3
Attach hanger to
the carrying member,
acute angle side
first. Install nails
at an angle.
LSU26
LSSU28
LSSU410
(LSSU210-2 similar)
LSSU INSTALLATION SEQUENCE
Joist
Width
Model
No.
Ga
Dimensions
Fasteners
W
H
A
Face
Joist
Uplift 2
(133)
Uplift 2
(160)
DF/SP Species Header
Allowable Loads
SPF Species Header
Allowable Loads
Floor
(100)
Roof
Floor
(100)
Roof
Snow
(115)
Const
(125)
Snow
(115)
Const
(125)
Sloped Only Hangers
LSU26
18
1
4
6-10d
5-10dx1
485
535
665
800
1
LSSU28
18
1
7
10-10d
5-10dx1
485
535
1110
1275
1390
960
1105
1200
1
LSSU210
18
1
8
10-10d
7-10dx1
730
875
1110
1275
1390
960
625
625
1105
1200
2
LSSUH310
16
2
8
18-16d
12-10dx1
1150
1150
2295
2295
2295
1930
1930
1930
3
LSSU210-2
16
3
8
18-16d
12-10dx1
1150
1150
2430
2795
3035
2160
2485
2700
3
LSSU410
16
3
8
18-16d
12-10dx1
1150
1150
2430
2795
3035
2160
2485
2700
Skewed Hangers or Sloped and Skewed
LSU26
18
1
4
6-10d
5-10dx1
485
535
665
800
1
LSSU28
18
1
7
9-10d
5-10dx1
450
450
885
885
885
765
765
765
1
LSSU210
18
1
8
9-10d
7-10dx1
730
785
995
1145
1205
860
995
1050
2
LSSUH310
16
2
8
14-16d
12-10dx1
1150
1150
1600
1600
1600
1385
1385
1385
3
LSSU210-2
16
3
8
14-16d
12-10dx1
1150
1150
1625
1625
1625
1365
3
LSSU410
16
3
1
1
1
1
1
765
575
415
415
415
415
660
690
765
575
660
690
1365
1365
6, 86,
140, 121
6, 86, 140
160
4, 87, 121
160
1, 84,140,121
1, 84
4, 87
Uplift 2
(133)
990
990
990
990
990
3
2
2
1
1
1
3
2
2
Code
Ref.
1.Roof loads are 125% of floor loads unless limited by other criteria.
2.Uplift loads include a 33% and 60% increase for earthquake or wind loading; no further increase is allowed;
reduce when other loads govern.
3.Truss chord cross-grain tension may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T-ANSITPISP and
T-ANSITPIDF for allowable loads that consider ANSI/TPI 1-2002 wood member design criteria.
4.NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
Available with additional corrosion protection. Check with factory.
[close]