Page 82 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
83
Solid Sawn Connectors
VPA Adjustable Variable Pitch Connectors
HCP Hip Corner Plates
Typical HCP Installation
The HCP connects a rafter or joist to double top plates at a 45 angle.
MATERIAL: 18 gauge.
FINISH: HCP2-galvanized or Z-MAX; HCP4Z-ZMAX .
INSTALLATION: Use all specified fasteners. See General Notes.
Attach HCP to double top plates; birdsmouth not required for table loads.
Install rafter and complete nailing. Rafter may be sloped to 45 .
CODES: See page 12 for Code Listing Key Chart.
Fasteners
Doug-Fir-Larch/
So. Pine
Allowable
Loads 1
Spruce-Pine-Fir
Allowable
Loads 1
To
Rafters
To
Plates
(133 160)
(133 160)
Uplift
F1
Uplift
F1
6-10dx1
6-10dx1
605
300
520
260
Model
No.
HCP2
HCP4Z
Member
Size
2x
4x
8-10d
8-10d
1000
265
860
230
Code
Ref.
9,
121
1.Loads may not be increased for short-term loading.
2.The HCP can be installed on the inside and the outside of the wall with a flat bottom
chord truss and achieve twice the load capacity.
3.Uplift loads include a 33% and 60% increase for earthquake or wind loading;
no further increase allowed; reduce where other loads govern.
4.NAILS: 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
Available with additional corrosion protection. Check with factory.
The VPA is adjustable to slopes between 3:12 and 12:12,
complementing the versatile LSSU.
No notching is required when using the VPA. This hanger
reduces the need for beveled plates and toe-nailing.
MATERIAL: 18 gauge
FINISH: Galvanized
INSTALLATION:
Use all specified fasteners. See General Notes.
CODES: See page 12 for Code Listing Key Chart.
SPF Species
Allowable Loads
Lateral
(133)
(160)
210
250
870
210
250
1020
210
250
1020
(133)
(160)
F1
F2
F1
F2
325
210
325
250
325
210
325
250
325
210
325
250
Download
Uplift
Joist
Width
Model
No.
W
Fasteners
DF/SP Species
Allowable Loads
Carrying
Member
Carried
Member
Lateral
(133)
(160)
1
VPA2
1
8-10d
2-10dx1
245
295
1050
2
VPA3
2
9-10d
2-10dx1
245
295
1230
1, 121, 140
3
VPA4
3
11-10d
2-10dx1
245
295
1230
(133)
(160)
F1
F2
F1
F2
375
245
375
250
375
245
375
250
375
245
375
250
Code
Ref.
Download
Uplift
1.Uplift loads include a 33% and 60% increase for earthquake or wind loading;
no further increase allowed; reduce where other loads govern.
2.Loads may not be increased for short-term loading.
3.NAILS: 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
STEP 4
Install 10dx1 nail into tab
nail hole. Hammer nail in at a
slight angle to prevent splitting.
STEP 1
Install top nails and face
PAN nails in A flange to
outside wall top plate.
STEP 2
Seat rafter with a hammer,
adjusting B flange to
the required pitch.
STEP 3
Install B flange nails
in the obround nail holes,
locking the pitch.
VPA INSTALLATION
SEQUENCE
VPA2
U.S. Patent 5,335,469
A and B
flanges touch
at 45
HCP2
(HCP4Z similar)
U.S. Patent 5,380,115
[close]