Page 89 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
90
This product is preferable to similar connectors because of a) easier installation,
b) higher loads, c) lower installed cost, or a combination of these features.
Engineered Wood Structural Composite Lumber Connectors
IUS/IUT/MIU I-Joist Hangers
The improved IUS is now fully compatible with shallow flange I-joists!
I-joists with flange thicknesses between 1 and 1 achieve the full
allowable table loads including uplift values and joist nails are not required! The
IUS is a hybrid hanger that incorporates the advantages of the face mount and top
mount hanger. Installation is fast with the Strong-Grip and Snap-In joist features
along with easy-to-reach face nail locations and self-jigging locator tabs.
The MIU series hangers are designed for commercial and high load I-joist
applications without requiring web stiffeners. The MIU features Positive Angle
Nailing (PAN), which minimizes splitting of the flanges while permitting time-saving
nailing from a better angle.
The IUT features a bend-tab which nails into the I-joists bottom flange when
web stiffeners are not used, or directly into the web stiffener. I-joist flange thickness
for bend-tab application is 1 to 1 ". This constrains the member, helping to
reduce squeaks resulting from joist movement.
MATERIAL: See table page 92-96. FINISH: Galvanized
UPLIFT LOADS: Models have optional triangle joist nail holes for additional
uplift. Properly attached web stiffeners are required.
IUT add two additional 10dx1 joist nails for a total uplift load of
480 lbs and 575 lbs (33% and 60% increase respectively).
MIU add four additional 10dx1 joist nails for a total uplift load of
720 lbs and 865 lbs (33% and 60% increase respectively).
IUS for additional uplift capacity options refer
to technical bulletin T-OPTUPLIFTCWP.
SIM PS O N
Strong Tie
MIU with correct
PAN installation
Typical IUT Installation
MIU
IUS
(some IUS models have
triangle holes in header
flanges for Min/Max nailing)
U.S. Patent 6,523,321
IUT
U.S. Patent
5,555,694
Bend tab
into the bottom
flange and fasten
with 10d x 1 nails
at approximately 45 .
STEP 3
Firmly push or snap
I-joist fully into the
seat of the IUS.
STEP 2
Slide the I-joist downward
into the IUS until it rests
above the large teardrop.
STEP 1
Attach the IUS to
the header
Starburst detail
allows secure
seating of joist.
SNAP-IN
TEARDROP
No nails
required!
Locator Tab
Strong-Grips
holds bottom
chord in
position.
INSTALLATION: Use all specified fasteners. Verify that the
header can take the required fasteners specified in the
table. See pages 88-89 for more installation information.
IUS fasten hanger to header. Position I-joist into
hanger and snap into place. No joist nailing required.
Some IUS models have triangle and round header nail
holes. To achieve Max. download, fill both round and
triangle holes.
IUS Locator tabs are not structural. They may be
bent back to adjust for hanger placement.
IUS for rimboard applications see T-RIMBDHGR.
IUT optional seat diamond hole allows alternate
attachment of hanger. See T-OPTUPLIFTCWP.
Web stiffeners are not required with I-joists when the
joist top flange is laterally supported by the sides of the
hanger. I-joist manufacturers may require web stiffeners.
OPTIONS:
These hangers cannot be modified. However, these
models will normally accommodate a skew of up to 5 .
For sloped joists up to :12 there is no reduction,
between :12 and up to :12, tests show a 10%
reduction in ultimate hanger strength. Local crushing
of the bottom flange or excessive deflection may be
limiting; check with joist manufacturer for specific
limitations on bearing of this type.
IUS INSTALLATION SEQUENCE