Page 96 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
97
Engineered Wood Structural Composite Lumber Connectors
THAI I-Joist Structural Composite Lumber Hangers
1. The W
dimension
should be
ordered at to
greater
than the
joist width.
Nailing Options
Fasteners
Allowable Loads
Top
Face
Joist
Uplift
(133)
Uplift
(160)
DF/SP LVL Species Header
DF/SP Species Header
SPF Species Header
Floor
(100)
Snow
(115)
Roof
(125)
Floor
(100)
Snow
(115)
Roof
(125)
Floor
(100)
Snow
(115)
Roof
(125)
THAI Minimum
4-10dx1
2-10dx1
2-10dx1
1400
1400
1400
1400
1400
1400
1060
1060
1060
4-10d
2-10d
2-10dx1
1715
1715
1715
1835
1835
1835
1590
1590
1590
THAI Maximum
20-10d
2-10dx1
215
215
2200
2200
2200
2200
2200
2200
1920
2200
2200
THAI-2 Minimum
4-10d
2-10d
2-10dx1
2020
2020
2020
2020
2020
2020
2020
2020
2020
THAI-2 Maximum
30-10d
2-10dx1
215
215
3390
3900
4135
3390
3900
4135
2940
3310
3310
Typical THAI
Installation with Minimum
Nailing Configuration
Typical
THAI-2
Installation
Typical THA29
Installation with Maximum
Nailing Configuration
1. Uplift loads are based on Doug Fir, and have been increased 33% and 60% for earthquake
or wind loading with no further increase allowed; reduce where other loads govern.
2. Roof loads are 125% of floor loads unless limited by other criteria.
3. The minimum header depth to achieve the maximum nail configuration is 16".
4. NAILS: 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information
Do not nail
within 1/4"
of multiple
ply seam.
Joist Dimensions
Model No.
Hanger Dimensions
Width
Depth
W 1
H
C
9 -14"
9 -14"
9 -14"
9 -14"
9 -14"
9 -14"
9 -14"
9 -14"
1
2
3
1
2
2 to 2
3 to 5
THAI222
THAI1.81/22
THAI3522
THAI322
2
1
2
3
1
2
2
3 to 5
2
9
8
8
9
9
9
8
9
22
22
21
22
22
22
21
22
THAI2.06/22
THAI2.1/22
THAI422
THAI-2
8, 36,
91, 121
121
Code
Ref.
Designed for I-joists, the THAI has extra long straps and can be field-formed
to give height adjustability and top flange hanger convenience. Positive angle
nailing helps eliminate splitting of the I-joists bottom flange.
MATERIAL: THAI-2-14 gauge; all others-18 gauge
FINISH: Galvanized
INSTALLATION: Factory-order the THAI-2 for hanger width needed.
See table for allowable widths.
Use all specified fasteners. Verify that the header can take the fasteners
specified in the table. Web stiffeners are required for all I-joists used with these hangers.
When a total of 20 face nails are used in THAI straps, or 30 face nails are
used in THAI-2 straps, the maximum load-carrying capacity is achieved. Reduce load given by allowable nail shear capacity for each nail less than maximum.
A minimum nailing configuration is shown for top nailing installations. The strap
must be field-formed over the top of the header by a minimum of 2 ".
CODES: See page 12 for Code Listing Key Chart.
THAI
(THAI-2 similar)
RC Ripper Clip
The Ripper Clip is designed to connect ripped 2x framing to the top
of another wood joist.
MATERIAL: 20 gauge FINISH: Galvanized
INSTALLATION: Use all specified fasteners. Refer to General Notes. Attach RC to ripper, then attach ripper/RC assembly to roof joist.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
W
Fasteners
Allowable
Uplift Load
F1
F2
Ripper
Joist
(133)
RC1.56
205
240
205
RC1.81
2-10dx1
2-10dx1
RC2.1
1
1
2
170
Code
Ref.
1. Allowable loads are for DFL ripper members.
2. Uplift loads have been increased 33% for earthquake or wind loading with no other
increase allowed. Reduce by 33% for normal loading.
3. Designer to consider stability/blocking requirements for system, if necessary.
4. Spacing of RC per Designer.
5. NAILS: 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
RC
U.S. Patent 5,603,580