Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 96 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog
Zoom in
View extracted text

Page 96 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie

97 Engineered Wood Structural Composite Lumber Connectors THAI I-Joist Structural Composite Lumber Hangers 1. The W dimension should be ordered at to greater than the joist width. Nailing Options Fasteners Allowable Loads Top Face Joist Uplift (133) Uplift (160) DF/SP LVL Species Header DF/SP Species Header SPF Species Header Floor (100) Snow (115) Roof (125) Floor (100) Snow (115) Roof (125) Floor (100) Snow (115) Roof (125) THAI Minimum 4-10dx1 2-10dx1 2-10dx1 1400 1400 1400 1400 1400 1400 1060 1060 1060 4-10d 2-10d 2-10dx1 1715 1715 1715 1835 1835 1835 1590 1590 1590 THAI Maximum 20-10d 2-10dx1 215 215 2200 2200 2200 2200 2200 2200 1920 2200 2200 THAI-2 Minimum 4-10d 2-10d 2-10dx1 2020 2020 2020 2020 2020 2020 2020 2020 2020 THAI-2 Maximum 30-10d 2-10dx1 215 215 3390 3900 4135 3390 3900 4135 2940 3310 3310 Typical THAI Installation with Minimum Nailing Configuration Typical THAI-2 Installation Typical THA29 Installation with Maximum Nailing Configuration 1. Uplift loads are based on Doug Fir, and have been increased 33% and 60% for earthquake or wind loading with no further increase allowed; reduce where other loads govern. 2. Roof loads are 125% of floor loads unless limited by other criteria. 3. The minimum header depth to achieve the maximum nail configuration is 16". 4. NAILS: 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information Do not nail within 1/4" of multiple ply seam. Joist Dimensions Model No. Hanger Dimensions Width Depth W 1 H C 9 -14" 9 -14" 9 -14" 9 -14" 9 -14" 9 -14" 9 -14" 9 -14" 1 2 3 1 2 2 to 2 3 to 5 THAI222 THAI1.81/22 THAI3522 THAI322 2 1 2 3 1 2 2 3 to 5 2 9 8 8 9 9 9 8 9 22 22 21 22 22 22 21 22 THAI2.06/22 THAI2.1/22 THAI422 THAI-2 8, 36, 91, 121 121 Code Ref. Designed for I-joists, the THAI has extra long straps and can be field-formed to give height adjustability and top flange hanger convenience. Positive angle nailing helps eliminate splitting of the I-joists bottom flange. MATERIAL: THAI-2-14 gauge; all others-18 gauge FINISH: Galvanized INSTALLATION: Factory-order the THAI-2 for hanger width needed. See table for allowable widths. Use all specified fasteners. Verify that the header can take the fasteners specified in the table. Web stiffeners are required for all I-joists used with these hangers. When a total of 20 face nails are used in THAI straps, or 30 face nails are used in THAI-2 straps, the maximum load-carrying capacity is achieved. Reduce load given by allowable nail shear capacity for each nail less than maximum. A minimum nailing configuration is shown for top nailing installations. The strap must be field-formed over the top of the header by a minimum of 2 ". CODES: See page 12 for Code Listing Key Chart. THAI (THAI-2 similar) RC Ripper Clip The Ripper Clip is designed to connect ripped 2x framing to the top of another wood joist. MATERIAL: 20 gauge FINISH: Galvanized INSTALLATION: Use all specified fasteners. Refer to General Notes. Attach RC to ripper, then attach ripper/RC assembly to roof joist. CODES: See page 12 for Code Listing Key Chart. Model No. W Fasteners Allowable Uplift Load F1 F2 Ripper Joist (133) RC1.56 205 240 205 RC1.81 2-10dx1 2-10dx1 RC2.1 1 1 2 170 Code Ref. 1. Allowable loads are for DFL ripper members. 2. Uplift loads have been increased 33% for earthquake or wind loading with no other increase allowed. Reduce by 33% for normal loading. 3. Designer to consider stability/blocking requirements for system, if necessary. 4. Spacing of RC per Designer. 5. NAILS: 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information. RC U.S. Patent 5,603,580 Typical RC Installation

[close]
Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 96 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog



All copyrights remain by their owners. Who-sells-it.com is not an official partner of Simpson Strong-Tie.


Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com