Page 98 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie99 Engineered Wood Structural Composite Lumber Connectors TOP FLANGE HANGERS ITT/MIT/HIT/ITTM Engineered Wood Products Hangers OPTIONAL NAILING FOR INCREASED UPLIFT NAILER TABLE This table indicates the maximum allowable loads for ITT/MIT/HIT hangers used on wood nailers. The header nail type must be substituted for those listed in other tables. 1. Loads are based on Doug Fir, and have been increased 33% and 60% for wind or earthquake loading with no further increase allowed. Reduce according to the code for normal loading criteria such as in cantilever construction. 2. Web stiffeners are required on I-joist for additional nailing. 1. These hangers may deflect an additional at design load. Model Fasteners Allowable Uplift Loads Top Face Joist (133) (160) ITT 4-10dx1 4-10dx1 4-10dx1 485 575 4-10d 4-10d 4-10dx1 485 575 4-16d 4-16d 4-10dx1 485 575 MIT 4-10dx1 4-10dx1 4-10dx1 480 575 4-16d 4-16d 4-10dx1 480 575 HIT 4-16d 6-16d 4-10dx1 480 575 4-16dx2 6-16dx2 4-10dx1 480 575 4-16d 6-16d 6-10dx1 720 850 Model Nailer Header Nailing Allowable Loads DF/SP SPF LSL ITT Series 2x 6-10dx1 1215 1215 1230 3x 6-16dx2 1550 1550 2-2x 6-10d 1215 1150 4x 6-16d 1550 1550 MIT Series 2x 6-10dx1 1570 1440 1605 3x 8-16dx2 1975 2-2x 8-10d 1570 1255 4x 8-16d 2250 HIT Series 3x 10-16dx2 2835 2-2x 10-10d 2525 4x 10-16d 3050 1 1 1 1 Model Fasteners Allowable Loads Header Type Top Face Joist Uplift (133) Uplift (160) LVL DF/SP PSL MID-WALL INSTALLATION 10 MID-WALL INSTALLATION 10 TOP OF WALL INSTALLATION LSL DF/SP Masonry SPF I-Joist SPF I-Joist Code Ref. ITT ITTM Series Series 4-10dx1 2-10dx1 2-10dx1 245 285 1235 1435 1235 1065 1050 4-10d 2-10d 2-10dx1 245 285 1450 1435 1615 1200 4-16d 2-16d 2-10dx1 245 285 1500 1500 1750 1315 MIT Series 4-10dx1 4-10dx1 2-10dx1 240 290 2035 1605 1950 1115 1230 755 885 4-10d 4-10d 2-10dx1 240 290 3-Titens 2-Titens 2-10dx1 2-10dx1 2-10dx1 225 225 225 225 1665 1665 1545 2335 1605 2400 1665 4-16d 4-16d 2-10dx1 240 290 2550 2115 2400 1665 HIT Series 4-16d 6-16d 2-10dx1 240 8, 36, 91, 121 1, 84, 121 170 2, 40, 82, 121 290 2550 1225 1300 1535 1500 2000 2140 2050 2500 3050 1950 DF/SCL 5 2 2 2-Titens 2 4 1 1 3 1. Uplift loads are based on Douglas Fir, and have been increased 33% and 60% for earthquake or wind loading with no further increase allowed. Divide by 1.33 and 1.60 for normal loading criteria like cantilever construction. For SPF use 0.86 x DF/SP uplift load. 2. Titen masonry screws are x1 . 3. Applies to LVL headers made primarily from Douglas Fir or Southern Pine. For LVL made primarily from Spruce Pine Fir or similar less dense veneers, use the values found in the SPF column. 4. DF I-joists include flanges made from solid sawn Douglas Fir, LVL made primarily of Douglas Fir/Southern Pine, or LSL. For flanges with thicknesses from 1 to 1 , use 0.85 of the I-joist header load. For flanges with thicknesses from1 to 1 , use 0.75 of the I-joist header load. 5. Minimum solid header thickness to achieve ITT table loads is 1 ". 6. SCL, structural composite lumber, is laminated veneer lumber, Parallam PSL and TimberStrand LSL. 7. Code Values are based on DF/SP header species. 8. ITTM loads are based on 2000 psi minimum concrete or grout. 9. I-joists with flanges less than 1 thick used in combination with hangers thinner than 14 gauge may deflect an additional inch beyond the standard limit. 10. Mid-wall installation requires minimum of one grouted course above and below the hanger. 11. ITTM411.88, ITTM414, and ITTM416 models are available. Parallam and TimberStrand are registered trademarks of Trus Joist, a Weyerhaeuser company. NAILS: 16d 0.162" dia. x 3 long, 16dx2 0.162" dia. x 2 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information. IT SERIES WITH VARIOUS HEADER APPLICATIONS POSITIVE ANGLE NAILING Correct Nailing Approx. 45 o angle Nail at wrong angle Do not bend tab Nail too long Use a 10dx1 nail (Simpson N10 HDG shown) Bend the tab with a hammer. Hammer the nail in at approximately 45 . The tab is now correctly installed. IUT ITT INSTALLATION (VPA SIMILAR) Some model configurations may differ from those shown on page 98. Contact factory for details.[close] |
Page 98 of 195 ![]() |
All Copyrights are and remain property of Simpson Strong-Tie. Who-sells-it.com is not an official partner of Simpson Strong-Tie. |