Engineered Wood Structural Composite Lumber Connectors
TOP FLANGE HANGERS ITT/MIT/HIT/ITTM Engineered Wood Products Hangers
OPTIONAL NAILING FOR INCREASED UPLIFT
NAILER TABLE
This table indicates the maximum allowable loads for ITT/MIT/HIT
hangers used on wood nailers. The header nail
type must be substituted for those listed in other tables.
1. Loads are based on Doug Fir, and have been increased 33% and 60% for wind
or earthquake loading with no further increase allowed. Reduce according to
the code for normal loading criteria such as in cantilever construction.
2. Web stiffeners are required on I-joist for additional nailing.
1. These hangers may deflect an additional at design load.
Model
Fasteners
Allowable Uplift
Loads
Top
Face
Joist
(133)
(160)
ITT
4-10dx1
4-10dx1
4-10dx1
485
575
4-10d
4-10d
4-10dx1
485
575
4-16d
4-16d
4-10dx1
485
575
MIT
4-10dx1
4-10dx1
4-10dx1
480
575
4-16d
4-16d
4-10dx1
480
575
HIT
4-16d
6-16d
4-10dx1
480
575
4-16dx2
6-16dx2
4-10dx1
480
575
4-16d
6-16d
6-10dx1
720
850
Model
Nailer
Header
Nailing
Allowable Loads
DF/SP
SPF
LSL
ITT Series
2x
6-10dx1
1215
1215
1230
3x
6-16dx2
1550
1550
2-2x
6-10d
1215
1150
4x
6-16d
1550
1550
MIT Series
2x
6-10dx1
1570
1440
1605
3x
8-16dx2
1975
2-2x
8-10d
1570
1255
4x
8-16d
2250
HIT Series
3x
10-16dx2
2835
2-2x
10-10d
2525
4x
10-16d
3050
1
1
1
1
Model
Fasteners
Allowable Loads Header Type
Top
Face
Joist
Uplift
(133)
Uplift
(160)
LVL
DF/SP
PSL
MID-WALL INSTALLATION 10
MID-WALL INSTALLATION 10
TOP OF WALL INSTALLATION
LSL
DF/SP
Masonry
SPF
I-Joist
SPF
I-Joist
Code
Ref.
ITT
ITTM Series
Series
4-10dx1
2-10dx1
2-10dx1
245
285
1235
1435
1235
1065
1050
4-10d
2-10d
2-10dx1
245
285
1450
1435
1615
1200
4-16d
2-16d
2-10dx1
245
285
1500
1500
1750
1315
MIT Series
4-10dx1
4-10dx1
2-10dx1
240
290
2035
1605
1950
1115
1230
755
885
4-10d
4-10d
2-10dx1
240
290
3-Titens
2-Titens
2-10dx1
2-10dx1
2-10dx1
225
225
225
225
1665
1665
1545
2335
1605
2400
1665
4-16d
4-16d
2-10dx1
240
290
2550
2115
2400
1665
HIT Series
4-16d
6-16d
2-10dx1
240
8, 36, 91, 121
1, 84, 121
170
2, 40, 82, 121
290
2550
1225
1300
1535
1500
2000
2140
2050
2500
3050
1950
DF/SCL
5
2
2
2-Titens
2
4
1
1
3
1.
Uplift loads are based on Douglas Fir, and have been increased 33% and 60% for earthquake
or wind loading with no further increase allowed. Divide by 1.33 and 1.60 for normal loading
criteria like cantilever construction. For SPF use 0.86 x DF/SP uplift load.
2. Titen masonry screws are x1 .
3.
Applies to LVL headers made primarily from Douglas Fir or Southern Pine. For LVL made primarily
from Spruce Pine Fir or similar less dense veneers, use the values found in the SPF column.
4. DF I-joists include flanges made from solid sawn Douglas Fir, LVL made primarily of
Douglas Fir/Southern Pine, or LSL. For flanges with thicknesses from 1 to 1 , use
0.85 of the I-joist header load. For flanges with thicknesses from1 to 1 , use 0.75 of
the I-joist header load.
5.
Minimum solid header thickness to achieve ITT table loads is 1 ".
6.
SCL, structural composite lumber, is laminated veneer lumber, Parallam
PSL and TimberStrand LSL.
7.
Code Values are based on DF/SP header species.
8. ITTM loads are based on 2000 psi minimum concrete or grout.
9. I-joists with flanges less than 1 thick used in combination with
hangers thinner than 14 gauge may deflect an additional inch
beyond the standard limit.
10. Mid-wall installation requires minimum of one grouted course above
and below the hanger.
11. ITTM411.88, ITTM414, and ITTM416 models are available.
Parallam and TimberStrand are registered trademarks of Trus Joist, a Weyerhaeuser company.
NAILS: 16d 0.162" dia. x 3 long, 16dx2 0.162" dia. x 2 long,
10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
IT SERIES WITH VARIOUS HEADER APPLICATIONS
POSITIVE ANGLE NAILING
Correct Nailing
Approx. 45 o angle
Nail at wrong angle
Do not bend tab
Nail too long
Use a
10dx1 nail
(Simpson
N10 HDG
shown)
Bend the tab
with a hammer.
Hammer
the nail in at
approximately 45 .
The tab is now
correctly installed.
IUT ITT INSTALLATION (VPA SIMILAR)
Some model configurations may differ from those shown on page 98.
Contact factory for details.