Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
|
| | ............... 169 AB/ABA/ABE/ABU Post Base ...................... 46 ABS ... Anchor Bolt Stabilizer.. 22 AC/ACE Post Cap................ 52 AnchorMate Bolt ... Hanger................... ....102 EPB Post Base..................... 47 EPB44PHDG ... Post Base .......47 EPB44T Post Base...............47 EPC Post Cap ... 50 LCC Lally Column Cap.........51 LCE Post Cap...................... .52 LEG ... 120 LMA Mudsill Anchor......24, 25 LPC Post Cap ......................52 LS Angle ... Ties/Angles...........184 OCB, OCC Caps/Bases.......184 OHU Hangers ... Purlin Anchor..............118 PB, PBS Post Base..............48 PBV Post Base ... ...................18 7 PC Post Cap ........................5 2 PCT ...
|
| | Hurricane Ties ................ 162-164 CAPS BASES Post/Column Caps and Bases ...
|
| | 46 Caps Bases AB/ABA/ABE/ABU Adjustable and ... Standoff Post Bases Model No. Nominal Post Size Material Dimensions Fasteners ... (Ga) Strap (Ga) W L H HB 6 Anch. Dia Post Uplift (133) Uplift (160) Down (100) ... is the distance from the bottom of the post up to the first bolt hole. 7. NAILS: ... ABU88 The AB is an adjustable post base which offers moisture protection ... and finished hardware appearance. Post Bases provide tested capacity. They ... They reduce the potential for decay at post and column ends. MATERIAL: AB 12 ga ... fasteners. See General Notes. Post bases do not provide adequate ... ). AB supplied as shown; position the post, secure the easy-access nut, then bend ...
|
| | 47 Caps Bases EPB44T/EPB44PHDG Elevated Post Bases EPB Elevated Post Bases Model No ... limited by buckling capacity of the post. 5. NAILS: 16d 0.162" dia. x 3 long. See ... limited by buckling capacity of the post. 5. NAILS: 16d 0.162" dia. x 3 long. See ... above concrete, 2" for EPB44A. Post bases do not provide adequate ... or AT Adhesive NEW! EPB44PHDG (Elevated Post Base Hot-Dip Galvanized) can be used ... and cast-in-place installation for 4x4 posts. MATERIAL: 12 gauge base. EPB44T ... , drill a hole in the center of the post and rotate the post base up or down to ... at least three threads in the base. Post bases do not provide adequate ...
|
| | 48 Caps Bases PB/PBS Regular and Standoff Post ... It reduces the potential for decay at post and column ends. MATERIAL: PB 12 gauge ... fasteners. See General Notes. Post bases do not provide adequate ... PBS44A Installation Model No. Nominal Post Size Material Dimensions Fasteners ... Base (Ga) Strap (Ga) W L H HB Anch. Dia Post Uplift (133) Uplift (160) F1 (133 160) ... limited by buckling capacity of the post. 6. When using structural composite ... lumber posts, bolts must be applied to the wide face ... of the post. 7. NAILS: 16d 0.162" dia. x 3 long. See ...
|
| | 49 Caps Bases CBSQ Column Bases This product is ... will not achieve the same load.) Post bases do not provide adequate ... will not achieve the same load.) Post bases do not provide adequate ...
|
| | 50 Caps Bases LCB/CB Column Bases Model No. ... of base plate flush with concrete. Post bases do not provide adequate ...
|
| | 51 Caps Bases BC/BCS Post Caps LCC Lally Column Caps Model No. ... 160) 1 W1 W2 L1 L2 H1 H2 Beam Surface Post Surface Post Top Surface Uplift Lateral ... CAPS BC4 3 3 2 2 3 3 3-16d 3-16d 980 ... Installation BC4 Cap/Base Lally column caps provide adequate bearing length for ... for the connection of 2-2xs to a 4x post or 3-2xs to a 6x post. Double shear ... nailing between beam and post gives added strength! The BC series ... offers dual purpose post cap/base for light cap or base ... at an angle through the beam into the post below to achieve the table loads BC: ... commons or 16dx2 joist hanger nails. Post bases do not provide adequate ...
|
| | LPC AC 52 Caps Bases AC/LPC/LCE Post Caps PC/EPC Post Caps PC Typical PC Post ... Cap Installation Typical EPC End Post Cap Installation A custom connection ... for post-beam combinations at medium design loads. ... : For end conditions, specify EPC post caps, providing dimensions are in accordance ... for Code Listing Key Chart. Model No. Post Size Dimensions Fasteners Each Side ... L2 L3 Surfaces Uplift PC/EPC Lateral 2 Post Beam PC Beam EPC (133) (160) PC (133/ ... members by means other than the post cap. 4. NAILS: 16d 0.162" dia. x 3 long ... Allowable Loads (133 160) 1 W L Beam Post Uplift Lateral AC4 (Min) 3 6 12-16d 8 ... spliced members by means other than the post cap. 7. NAILS: 16d 0.162" dia. x 3 long ...
|
| | 53 Caps Bases CCQ/ECCQ Column Caps This product is preferable to similar ... 7245 6270 16 14 11 7 Uplift Down L Beam Post CCQ86SDS2.5 CCQ88SDS2.5 CCQ96SDS2.5 ... do not apply to splice conditions. 4. Post sides are assumed to lie in the same ... govern. 7. ECCQ downloads assume a post of W1 x W2. 8. When using structural ... the beam and 14-SDS screws into the post. 10. Beam depth must be greater than 7 ...
|
| | alternatives for replacing column caps by using a combination of connectors. ... consider this connector combination. 54 Caps Bases CC Column Caps CC L 3 3 11 6 4 ... Fasteners Allowable Loads W1 W2 H1 Beam Post Uplift Down Qty Dia Qty Dia (100) (160 ... 7 13 8 4 2 6320 7585 68250 CC7 -7 1. Post sides are assumed to lie in the same ... limited by the W1 dimension). Column caps with W1, L, H1, and hole schedules ...
|
| | 55 Caps Bases ECC/ECCU Column Caps L ECC 3 3 7 6 2 2 6125 3 5 7 6 ... Fasteners Allowable Loads W1 W2 H1 Beam Post Uplift ECCU Down ECC/ECCU Qty Dia Qty ... 36750 4855 10 4 ECC7 -7 ECC ECCU 1. Post sides are assumed to lie in the same ... limited by the W1 dimension). Column caps with W1, L, H1, and hole schedules ... per 2001 NDS. 5. ECC downloads assume a post of W1 x W2. 6. Uplift loads assume ... alternatives for replacing column caps by using a combination of connectors. ...
|
| | value of beam, end bearing value of post, L/R of post, or other criteria are ... limiting. 3. Post sides are assumed to lie in the same ... OECC. Model No. Dimensions Bolts Beam Post Uplift Down Ga W2 L Qty Dia Code Ref. ... 37810 37810 54600 (100) (133) COLUMN CAPS 1. Load values allowed assume a ...
|
| | bottom of base flush with concrete. Post bases do not provide adequate ... -7 ga. Model No. Dimensions Bolts Beam Post Uplift Down Ga W2 L Qty Dia Code Ref. ... ; reduce where other loads govern. 2. Post sides are assumed to lie in the same ... ; reduce where end bearing value of post, L/R of post, or other criteria are ... PC to the model, i.e. CC3 -4PC. COLUMN CAPS INSTALLATION: Bolt holes shall be a ...
|