67 results for simpson strong ties h 10 found in 0.000 seconds

Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie

Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie



simpson strong ties h 10 in Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie


 
Show page 13
IMPORTANT INFORMATION GENERAL NOTES a. Simpson Strong-Tie Co., Inc. reserves the right ... such changes. b. Steel used for each Simpson product is individually selected based ... nails may not be combined to achieve highest load value. 8d (0.131"x2 "), 10d (0.148 ... according to the code. In many cases, Simpson code reports will indicate loads ... derived from Doug Fir header material only. However under ICC-ES ... listed by NDS. For your convenience we have placed the section from the AC13 ... 3.2.3 The species of lumber used shall have a specific gravity of 0.49 or greater ... 0.55 Spruce-Pine-Fir (SPF) 425 psi 0.42 Hem Fir (HF) 405 psi 0.43 Glulam 560 psi 0. ... PSL 750 psi 0.50 f. For face-mount hangers straight straps, use 0.86 of table ...
 
Show page 20
or SET Epoxy. Inspection is easy; the head is stamped with rod length and No Equal ... C. FINISH: Zinc Plated, available in HDG. See page 29-32 for application ... #5X5 5 4 RFB#4X6 6 RFB#4X7 7 RFB#4X10 10 5 RFB#5X8 8 8 RFB#5X10 10 RFB#5X16 ... 16 RFB#6X10.5 10 10 Available with additional corrosion ... . Check with factory. RFB CNW/HSCNW Coupler Nuts Model No. Rod Diameter H ... Min Allowable Tension Capacity (lbs.) (100) CNW 0.625 1 CNW 0.750 2 CNW 0.875 ... 3 5875 160 3750 8460 11500 15035 23490 HSCNW 0.750 2 2 HSCNW1 1.000 18225 32400 ... correct all thread rod installation HSCNW High Strength Coupler Nut CNW ... installed when visible through CNWs and HSCNWs witness holes. Standard CNWs and HSCNWs ...
 
Show page 34
For holdowns, per ASTM test standards, anchor bolt ... be finger-tight plus to turn with a hand wrench, with consideration given to ... wrenches should not be used. NEW! The HDU series of holdowns are the latest in a ... long series of innovations from Simpson. These holdowns combine the advantages ... of low deflection and high capacity from the pre-deflected ... with the ease of installation of Simpsons patented SDS screws. HDU SPECIAL ... . SDS x2 screws are supplied with the holdowns. (Lag screws will not achieve the same ... . See General Notes. Place the HDU over the anchor bolt. No additional ... page 33-34 for anchorage options. See Simpson Anchor Systems catalog for tested, ...
 
Show page 35
36 Anchors PHD Predeflected Holdown HDQ8 Holdown Model No. Ga Dimensions ... Fasteners Allowable Tension Loads SPF/HF (133/160) Holdown 5 Deflection at ... Highest Allowable Design Load Flush W H B Anchor Dia. No. of Simpson SDS x3 ... Wood Screws PHD2-SDS3 14 3 9 2 1 10 3375 .063 PHD5-SDS3 14 3 11 2 1 ... 1 18 5480 .068 PHD8-SDS3 deleted see HDQ8-SDS3 and HDU8-SDS2.5 Holdown 5 Deflection at ... Highest Code Ref. Allowable Design Load Raised ... , 98, 122 ,140 C L 1.Allowable loads have been increased for earthquake or wind ... the wood screw value. 5.Deflection at Highest Allowable Design Load: The deflection ... of a holdown measured between the anchor bolt and ... the strap portion of the holdown when loaded to the highest allowable ...
 
Show page 36
37 Anchors HHDQ Heavy Duty Holdowns HDC Concentric Holdown Ga W Model No. H B ... Allowable Tension Loads DF/SP (133/160) Holdown Deflection at Highest Allowable Tension ... Design Load Code Ref. HHDQ11-SDS2.5 7 3 15 24 11445 0.076 HHDQ14-SDS2.5 ... 1 1 1 1 Allowable Tension Loads SPF/HF (133/160) 9615 12350 1. Allowable loads ... have been increased for earthquake or wind ... by 3, or the SDS wood screw value. 3. HHDQs can be raised off the sill with no ... in load or increase in deflection. HHDQ11 Vertical HHDQ11 Installation The heavy- ... duty HHDQ holdowns combine low deflection and high loads ... with ease of installation by using Simpsons patented SDS screws. FINISH: Gray ...
 
Show page 38
39 Anchors HDA/HD Holdowns Model No. Material Dimensions ... Fasteners Body Ga Base Ga HB 4 SB W H B SO CL Anchor Dia 5 Stud Machine ... Bolts Qty Dia HD2A 7 12 4 2 2 8 2 1 2 HD5A 3 10 5 ... 3 3 9 3 2 2 HD6A 7 6 3 3 11 3 2 2 HD8A 7 6 3 3 ... 14 3 2 3 HD10A 7 6 3 3 18 3 2 4 HD14A 3 7 4 3 ... 20 3 2 1 4 1 HD15 3 7 4 3 24 4 3 2 1 5 1 Model ... No. HD2A HD5A HD6A HD8A HD10A HD14A HD15 Code Ref. Wood Member Thickness 1 2 2 ... 117 0.125 0.121 0.269 0.282 0.082 40, 105, 122 Holdown 9 Deflection at Highest ... Allowable Design Load Holdown 9 Deflection at Highest Allowable ... 133/160) Allowable Tension Loads SPF/HF (133/160) 8. See page 13-15 for testing ...
 
Show page 45
Loads (DF/SP) Base (Ga) Strap (Ga) W L H HB 6 Anch. Dia Post Uplift (133) Uplift ... (160) Down (100) Nails Nails Bolts Nails Bolts Qty Dia ... ABA44 4x4 16 16 3 3 6-10d 555 555 6000 5, 41, 121 5, 41, 121 6 ... 8, 36, 91, 127 ABE44 4x4 16 16 3 3 6-10d 520 520 6665 ABU44 4x4 16 12 3 3 ... 2160 6665 ABA44R RGH 4x4 16 16 4 3 6-10d 555 555 8000 ABE44R RGH 4x4 16 16 ... 4 3 6-10d 400 400 6665 ABE46 4x6 12 16 3 5 ... 12 3 5 2 12-16d 2 2255 2300 2300 2300 10335 ABE46R RGH 4x6 12 16 4 5 8-16d 810 ... 6x6 14 14 5 5 8-16d 720 720 10665 ABE66 6x6 12 14 5 5 8-16d 900 900 ... 12000 ABU66 6x6 12 10 5 5 1 12-16d 2 2300 2300 2300 2300 ... , 127 9, 121 5, 41, 121 1. Uplift loads have been increased for earthquake or wind ...
 
Show page 52
because of a) easier installation, b) higher loads, c) lower installed cost, or a ... 7 gauge; all others 3 gauge. FINISH: Simpson gray paint, available in HDG with HDG ... provided. See General Notes. Install Simpsons SDS x2 wood screws, which are provided ... Width Dimensions Allowable Loads W1 W H Uplift (133) (160) (100) CCQ64SDS2.5 5 ... 5680 7655 11 7 CCQ5-4SDS2.5 5 3 8 10045 5680 5680 16 14 11 7 CCQ5-6SDS2.5 5 5 ... 8 7 7 8 16 36750 7245 6270 14 11 (100) 37815 37815 37815 37815 41580 24065 ... 7245 6270 14 11 7245 6270 14 11 46, 107, 124 46, 107, 124 160 160 Down 7 3 ... 6 6 6 4x 3 3 4x 5 5 5 8x 8 8 10x 8x 7 7 7 7 CCQ7.1-4SDS2.5 CCQ7.1-6SDS2. ... for short-term loading. 6. Uplift loads have been increased for earthquake or wind ...
 
Show page 59
60 Shearwall STEEL STRONG-WALL SSWT Exterior* Installation (May be ... CONCRETE SSWTPF (Panel Form) 2" 1. The height of the garage curb above the garage ... slab is critical for rough header opening at garage return walls. 2. See ... Garage Header Rough Opening Height table. 3. Templates are recommended and ... SSW15x10 SSW15x11 SSW15x12 SSWT12 Steel Strong-Wall Template Model SSWTPF12 SSWTBL12 Steel ... Strong-Wall Model Width (in) 12 SSWT15 SSWTPF15 ... SSWT Interior* Installation Anchor Bolt Height Nominal Height of Panel (feet) 8 9 10 ... 11 12 13 1000 200 140 105 NA NA NA 7500 90 55 25 NA NA NA ... 1000 165 130 100 80 70 NA 7500 95 65 45 30 15 NA ... Load (lbs) 12" wide 15" wide 195 135 105 21" wide 24" wide 80 65 7500 260 185 ...
 
Show page 61
62 Shearwall STRONG-WALL SHEARWALL Standard Strong-Wall ... U.S. Patents 5,706,626; 6,006,487, 6,109,850, 6,327,831, and 6,643,986 The building ... of the structure. Naming Scheme 8' to 10' SW24x8 Strong-Wall Width (in.) Nominal ... Height (ft.) CODES: See page 12 for Code ... Listing Key Chart. The Strong-Wall Shearwall can be installed around ... lateral resistance is required. Strong-Wall Shearwalls can reduce the amount of ... allowing for more windows and doors in house designs. Standard models are used for ... to the embedded bolts with the provided hardware. The top of the wall attaches with pre- ... top plates or can fasten to various header materials. PREFABRICATED The high- ...
 
Show page 63
64 Shearwall STRONG-WALL SHEARWALL RAISED FLOOR 2nd FLOOR The ... . Engineer of record must specify if high strength all-thread rod is required, ... available on website. 5. Maximum shim height between Strong-Wall and top plates or ... header is ". Shims of greater thickness will ... allowable vertical load table below for Strong-Wall maximum compression and tension ... installations on CMU. Model No. W (in) H (in) T (in) Number of Fasteners in Top ... Number of Fasteners in Bottom of Wall Holdown 3 Anchor Bolts Allowable Shear V Load ( ... 7/8" ATR 2790 .429 697 149 SW24x9-RF 24 105 3 12-SDS x6 16-SDS x6 7/8" ATR 960 . ... 337 481 101 SW32x9-RF 32 105 3 16-SDS x6 20-SDS x6 7/8" ATR 1420 . ... 406 532 128 SW48x9-RF 48 105 3 24-SDS x6 28-SDS x6 7/8" ATR 2395 . ...
 
Show page 65
66 Shearwall STRONG-WALL SHEARWALL The building designer shall ... structure. GARAGE PORTAL SYSTEMS 1. The height of the garage curb above the garage ... slab is critical for rough header opening on portal walls. 2. One 1/2" ... . 22" Garage Portal Model No. W (in) H (in) T (in) Number of Fasteners in ... (lb/ft) Number of Mudsill Anchors 6 Holdown 2 Anchor Bolts Wall Weight (lbs) Code ... Ref. 34, 101 34, 101 34, 60,101,137 34, 60,101,137 SW16x7x4 SW16x7x6 ... 2800 2800 2490 2490 4820 4820 3990 3990 1050 1050 935 935 1315 1315 1090 1090 90 112 ... 95 120 95 117 105 130 .367 .367 .420 .420 .369 .369 .446 ... 446 8-SDS x6 8-SDS x6 8-SDS x6 8-SDS x6 10-SDS x6 10-SDS x6 10-SDS x6 10-SDS x6 2- ...
 
Show page 66
67 Shearwall STRONG-WALL SHEARWALL The building designer shall ... , use the SSTB34. 3. Recommended header moisture content is 19% or less at time ... portal system consists of 1 wall with a header spanning over the top and connected as ... 5/8"x12" mudsill anchor. 6. The minimum header sizes listed are the minimum required ... rigidity of the portal system. Larger headers may be required due to vertical loading ... inside or outside. 8. Maximum shim height between Strong-Wall Portal Walls and ... header is ". Shims of greater thickness will ... vertical load table on page 64 for Strong-Wall maximum compression and tension ... capacities. 10.Capacities must be reduced as limited by anchor ... on CMU. Model No. W (in) H (in) T (in) Number of Fasteners in ...
 
Show page 69
70 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) CODES: See ... Installed Cost Index (ICI) Code Ref. W H B Header Joist Uplift Floor (100) Snow ... (115) Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES ... 2x4 LU24 20 1 3 1 4-10d 4-16d 2-10dx1 LUS24 18 1 3 1 4-10d 2-10d + 3% ... U24 16 1 3 1 4-10d 4-16d 2-10dx1 240 290 445 530 510 610 555 665 + 67% ... HU26 14 1 3 2 4-16d 2-10dx1 240 290 535 615 670 + 295% DBL ... 4-16d 2-16d Lowest U24-2 16 3 3 2 4-10d 4-16d 2-10d 295 355 445 530 510 610 555 ... 665 + 33% HU24-2 14 3 3 2 4-16d 2-10d 300 360 535 615 670 + 240% 2x6 ... LUS26 18 1 4 1 4-10d 4-10d Lowest LU26 20 1 4 1 6-10d 6-16d 4- ...
 
Show page 70
71 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) CODES: See ... Pine Allowable Loads Code Ref. W H B Joist Uplift Roof (125) 10d (133) ( ... 160) 10d 16d 10d 16d 10d 16d 2x12 LU210 20 1 7 1 10-10d 10-16d ... 6-10dx1 11% U210 16 1 7 2 10-10d 10-16d 6-10dx1 720 865 1110 1330 1275 1530 ... 1390 1660 + 53% HU212 14 1 9 2 10-16d 6-10dx1 720 865 1340 1540 1675 ... + 347% HUS210 16 1 9 3 30-16d 10-16d 2845 3000 3775 3920 4020 + 378% ... 8-16d 6-16d Lowest U210-2 16 3 8 2 14-10d 14-16d 6-10d 890 1065 1555 1860 1785 ... 2140 1940 2330 + 40% LUS214-2 18 3 10 2 10-16d 6-16d + 56% HUS210-2 14 3 ... 2050 2590 2010 2310 2510 + 136% HUS212-2 14 3 10 2 10-16d 10-16d 2560 3240 ...
 
Show page 71
72 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) Joist Size ... Loads Installed Cost Index (ICI) W H B Header Joist Uplift Floor (100) Snow (115) ... Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES 4x8 LUS46 ... 4-16d 4-16d Lowest U46 16 3 4 2 8-10d 8-16d 4-10d 590 710 890 1065 1020 1225 ... % LUS48 18 3 6 2 6-16d 4-16d + 40% HUS48 14 3 6 2 6-16d 6-16d 1550 1550 ... 1505 1730 1885 + 203% HU48 (Min) 14 3 6 2 10-16d 4-10d 605 725 ... 1340 1540 1675 + 213% HU48 (Max) 14 3 6 2 14-16d 6-10d 905 1085 ... 8-16d 6-16d + 19% U410 16 3 8 2 14-10d 14-16d 6-10d 890 1065 1555 1860 1785 ... 2140 1940 2330 + 74% HUS410 14 3 8 2 8-16d 8-16d 2160 2590 ...
 
Show page 72
73 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size ... Spruce-Pine-Fir Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) ... Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES 2x4 LU24 ... 20 1 3 1 4-10d 4-16d 2-10dx1 LUS24 18 1 3 1 4-10d 2-10d U24 16 ... 1 3 1 4-10d 4-16d 2-10dx1 210 250 385 460 440 530 480 575 ... HU26 14 1 3 2 4-16d 2-10dx1 210 250 465 535 580 DBL 2x4 LUS24- ... 3 2 4-16d 2-16d U24-2 16 3 3 2 4-10d 4-16d 2-10d 255 305 385 460 440 ... 530 480 575 HU24-2 14 3 3 2 4-16d 2-10d 260 315 465 ... 535 580 2x6 LUS26 18 1 4 1 4-10d 4-10d LU26 20 1 4 1 6-10d 6-16d 4- ... 10dx1 U26 16 1 4 2 6-10d 6-16d 4-10dx1 415 500 575 690 660 795 720 860 ...
 
Show page 73
74 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size ... Spruce-Pine-Fir Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) ... Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES DBL 2x12 ... 2 8-16d 6-16d U210-2 16 3 8 2 14-10d 14-16d 6-10d 770 920 1345 1610 ... 1545 1850 1680 2010 LUS214-2 18 3 10 2 10-16d 6-16d HUS210-2 14 3 9 2 ... 8-16d 1755 2105 1650 1900 2065 HUS212-2 14 3 10 2 10-16d 10-16d 2195 2630 ... 2065 2375 2580 HU212-2 (Min) 14 3 10 2 16-16d 6-10d 785 940 1855 2135 ... 2320 HU212-2 (Max) 14 3 10 2 22-16d 10-10d 1305 1570 2550 ... 2x12 LUS210-3 18 4 8 2 8-16d 6-16d HU212-3 (Min) 14 4 10 2 16-16d 6-10d 785 940 ...
 
Show page 74
75 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size ... Spruce-Pine-Fir Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) ... Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES 4x8 LUS46 ... 3 4 2 4-16d 4-16d U46 16 3 4 2 8-10d 8-16d 4-10d 510 615 770 920 885 ... 1060 960 1150 LUS48 18 3 6 2 6-16d 4- ... 16d HUS48 14 3 6 2 6-16d 6-16d 1315 1550 ... 1240 1425 1550 HU48 (Min) 14 3 6 2 10-16d 4-10d 525 625 1160 1335 1450 HU48 ... (Max) 14 3 6 2 14-16d 6-10d 785 940 1625 1870 2030 4x10 LUS48 ... 8 2 8-16d 6-16d U410 16 3 8 2 14-10d 14-16d 6-10d 770 920 1345 1610 1545 ... 1850 1680 2010 HUS410 14 3 8 2 8-16d 8-16d 1755 2105 ...
 
Show page 75
76 Solid Sawn Connectors FACE MOUNT HANGERS ROUGH LUMBER (DF SP) FACE MOUNT HANGERS ... Larch/Southern Pine Allowable Loads W H B Header Joist Uplift Floor (100) Snow ... (115) Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d ROUGH LUMBER SIZES ... 2x4(R) LU24R-18 18 2 3 1 4-16d 2-10dx1 U24R 16 2 3 2 4-10d 4-16d 2-10dx1 ... 665 2x6(R) LU26R-18 18 2 4 1 6-16d 4-10dx1 U26R 16 2 5 2 8-10d 8-16d 4-10dx1 ... 480 575 890 1065 1020 1225 1110 1330 2x8(R) LU28R-18 18 2 ... 6 1 8-16d 6-10dx1 U26R 16 2 5 2 8-10d 8-16d 4-10dx1 ... 480 575 890 1065 1020 1225 1110 1330 2x10(R) LU210R-18 18 ... 2 7 2 10-16d 6-10dx1 U210R 16 2 9 2 14-10d 14-16d 6- ...
 
Show page 77
78 Solid Sawn Connectors TOP FLANGE HANGERS W/WPU/WNP/WM/WMU/HW/HWU WM (WMU ... Model Joist Fasteners Allowable Loads Header Type Width Depth Top Face Joist Uplift ... SPF I-Joist Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 1600 1415 170, ... 124 170 2-10d 2-10dx1 2150 2020 2200 1435 2-16d 2- ... 10dx1 2335 1950 2335 1765 1435 WM 2-16d ... DPLX 2-10dx1 4175 WMU 4- x1 Titens 2- x1 Titens 2 ... - x1 Titens 9 to 28 6-10dx1 3380 3 to 30 3-10dx1 2-10dx1 2865 ... 3250 2500 2000 2030 3-10d 2-10dx1 2525 3250 3650 3255 2525 3-16d 2- ... 10dx1 3635 3320 3650 3255 2600 WPU/ WNPU 3 ... -16d 4-16d 6-10dx1 775 625 545 4700 4880 3650 4165 4165 ... 3-16d 4-16d 6-10dx1 485 4700 4880 3650 4165 4165 23 to ... 28 3-16d 4-16d 6-10dx1 315 4700 4880 3650 4165 4165 HW 4- ...
 
Show page 78
79 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) 1.N54A ... fasteners are supplied with hangers. 2.16d sinkers may be used where 10d ... no load reduction. 3. Uplift loads have been increased 33% and 60% for ... Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift ( ... 160) Floor (100) Snow (115) Roof (125) SAWN LUMBER ... SIZES 2x4 HU24TF 12 1 3 2 2 6-16d 2-10dx1 245 295 2090 2100 2100 Lowest DBL ... 2x4 HU24-2TF 12 3 3 2 2 8-16d 2-10d 310 375 2600 2600 2600 Lowest 2x6 JB26 ... 18 1 5 1 1 4-10d 2 PRONG 1040 1040 1040 Lowest LB26 14 1 5 1 1 4-16d 2 ... -10dx1 240 290 1380 1380 1380 + 117% HU26TF 12 1 5 2 2 10-16d 4-10dx1 490 590 ... 2330 2335 + 568% W26 12 1 5 2 2 2-10d 2-10dx1 2200 2200 2200 + 890% WM26 12 ...
 
Show page 79
80 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) Joist or ... Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift ( ... 160) Floor (100) Snow (115) Roof (125) SAWN LUMBER ... SIZES TPL 2x16 HU216-3TF 12 4 15 2 2 20-16d 8-16d 1470 1765 ... 5050 5050 5050 Lowest 3x4 HU34TF 12 2 3 2 2 8-16d 2-10dx1 245 295 ... 2600 2600 * 3x6 W36 12 2 5 2 2 2-10d 2-10dx1 2200 2200 2200 * WM36 12 2 5 ... 3 3 2-16d DPLX 2-10dx1 4100 4130 4150 * HU36TF 12 2 5 2 2 ... 10-16d 4-10dx1 490 590 3725 3900 3900 * 3x8 W38 12 2 ... 7 2 2 2-10d 2-10dx1 2200 2200 2200 * WM38 12 2 7 3 3 2- ... 16d DPLX 2-10dx1 4100 4130 4150 * HU38TF 12 2 7 2 2 12-16d 4-10dx1 490 590 ... * B38 12 2 7 2 2 14-16d 6-16dx2 1010 1010 3800 3800 3800 * 3x10 W310 12 2 9 ...
 
Show page 80
81 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) See footnotes ... Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift ( ... 160) Floor (100) Snow (115) Roof (125) SAWN LUMBER ... SIZES 4x14 HUS414TF 14 3 13 2 2 12-16d 8-16d 2160 ... 12 3 13 + 8% WNP414 12 3 13 2 2 2-10d 2-10d 3255 3255 3255 + 13% HU414TF 12 ... 3 13 2 2 18-16d 8-10d 1250 1500 4830 5050 5050 + 89% HW414 11 ... 3 13 2 2 4-10d 2-10d 5285 5285 5285 + 108% HHB414 7 3 13 ... 150% WM414 12 3 13 2 3 2-16d DPLX 2-10d 4175 4175 4175 * 4x16 WNP416 12 3 15 ... 2 2 2-10d 2-10d 3255 3255 3255 Lowest B416 12 3 15 ... + 23% HU416TF 12 3 15 2 2 20-16d 8-10d 1250 1500 5050 5050 5050 + 81% HW416 11 ... 3 15 2 2 4-10d 2-10d 5285 5285 5285 + 108% HHB416 7 3 15 ...
 
Show page 81
because of a) easier installation, b) higher loads, c) lower installed cost, or a ... Adjustable Light Slopeable/Skewable U Hangers This series attach joists or rafters to ... headers, sloped up or down, and skewed left or ... sloped joist at both ends so that the horizontal force developed by the slope is fully ... for Code Listing Key Chart. STEP 1 Nail hanger to slope-cut carried member, ... . Bend one time only. STEP 3 Attach hanger to the carrying member, acute angle ... Model No. Ga Dimensions Fasteners W H A Face Joist Uplift 2 (133) Uplift 2 ( ... 160) DF/SP Species Header Allowable Loads SPF Species Header ... Allowable Loads Floor (100) Roof Floor (100) Roof Snow (115) Const (125) Snow (115 ... ) Const (125) Sloped Only Hangers LSU26 18 1 4 6-10d 5-10dx1 485 535 ...
 
Show page 85
86 Solid Sawn Connectors SUR/SUL/HSUR/HSUL Skewed 45 Hangers This product is ... because of a) easier installation, b) higher loads, c) lower installed cost, or a ... Installation Dimensions Fasteners W H B A1 A2 Face Joist Uplift (133) ... Uplift (160) DF/SP Species Header Allowable Loads SPF Species Header ... Allowable Loads Floor (100) Roof Floor (100) Roof Snow (115) Const (125) Snow (115 ... ) Const (125) 1 8 2 1 1 10-16d 10-10dx1 1200 1250 1330 1530 1660 1150 ... 1320 1440 1 10 2 1 1 12-16d 12-10dx1 1440 1730 1595 1835 1995 1380 ... 1585 1725 2 8 2 1 2 14-16d 6-10dx1 720 765 1860 2140 2330 1610 1785 ... 1785 2 13 2 1 2 18-16d 8-10dx1 960 1150 2395 2500 2500 1795 1795 ... 1795 3 8 2 1 2 14-16d 6-16dx2 1065 1275 1860 2140 2330 1610 1850 ...
 
Show page 86
87 Solid Sawn Connectors HF26N/F Panelized Construction Hangers Model ... Fasteners Allowable Roof Loads (125) W H TF Header HF24N 2x4 1 3 1 2-10dx2 ... 575 F26P 2x6 1 5 1 2-10d 585 HF26N 2x6 1 5 1 2-10dx2 660 F34 3x4 2 3 ... 1 2-10d 650 HF34N 3x4 2 3 1 2-10dx2 575 F36 3x6 2 5 1 2-10d 685 HF36N ... 3x6 2 5 1 2-10dx2 660 20, 37, 80, 124 20, 37, 80, 124 4 ... 87,121 160 160 F24-2 (2)2x4 3 3 1 2-10d 735 F26-2 (2)2x6 3 5 1 2-10d 800 F44 ... 4x4 3 3 1 2-10d 880 F46 4x6 3 5 1 2-10d 785 Code Ref ... . F26P Typical Panelized Roof System F hangers are only for panelized roof ... construction Typical HF24N Installation (HF34N similar) Support ... member not shown for clarity HF24N (HF34N similar) U.S. Patent 6,260,402 The ...
 
Show page 90
Composite Lumber Connectors FACE MOUNT HANGERS U/HU I-Joist Structural Composite ... Lumber Hangers FACE MOUNT HANGERS HUCQ/HUS/HHUS/HGUS Double Shear SCL Hangers ... HUS410 Typical HU7 Installation Typical HUCQ Installed on End of a Beam Typical HU7 ... Installation See Hanger tables on pages 92 to 96. See Hanger ... Options on page 188 for hanger modifications, which may result in ... reduced loads. These hangers have the highest loads of any face mount hangers! All ... hangers in this series have double shear nailing, except the HUCQ ... General Notes. Do not use double shear hangers with I-joists. Nails must be driven at ... through the joist or truss into the header to achieve the table loads. Not ...
 
Show page 91
Composite Lumber Connectors FACE MOUNT HANGERS I-JOISTS Actual Joist Size Model No. ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... Roof (125) IUS1.56/9.5 18 1 9 2 8-10d 75 75 935 1075 1170 810 930 ... 1010 935 1075 1170 810 930 1010 44, 108, 126 935 1075 1170 810 930 1010 ... MIU1.56/9 16 1 8 2 16-16d 2-10dx1 240 255 2270 2615 2840 1970 2265 2460 ... 1970 2265 2460 IUT214 18 1 13 2 14-10dx1 2-10dx1 245 255 1275 1465 1590 1090 ... 1255 1365 1 13 2 14-10d 2-10dx1 245 255 1555 1785 1875 1345 1545 1680 ... IUS1.81/9.5 18 1 9 2 8-10d 75 75 IUT9 18 1 9 2 8-10dx1 2- ...
 
Show page 92
Composite Lumber Connectors FACE MOUNT HANGERS I-JOISTS 1. 10d commons or 16d sinkers ... may be used instead of the specified 10d commons with no load reduction. 3. ... Uplift loads based on Douglas Fir have been increased 33% and 60% for ... quantity and load values fill all round holes; MAX nailing quantity and load values ... fill all round and triangle holes. 5. Hangers sorted in order of recommended ... . 6.NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... /18 16 2 2 2 2 2 17 2 26-16d 2-10d ´1 240 255 HU3524/30 (Min) 3 14 18 2 ... 18-16d 8-10d´1 960 1150 2410 2775 3015 2090 2400 2610 ...
 
Show page 93
Composite Lumber Connectors FACE MOUNT HANGERS I-JOIST Actual Joist Size Model No. Web ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... .56/14 (Min) 18 IUT414 3 13 2 14-10dx1 2-10dx1 245 255 1275 1465 1590 1090 ... 1255 1365 3 13 2 14-10d 2-10dx1 245 255 1555 1785 1940 1345 1545 1680 ... MIU3.56/14 16 3 13 2 22-16d 2-10dx1 240 255 3125 18 IUT416 3 15 2 16- ... 10dx1 2-10dx1 245 255 1455 1675 1820 1250 1435 1560 ... 3 15 2 16-10d 2-10dx1 245 255 1775 2040 2165 1535 1765 1920 ... MIU3.56/16 16 3 15 2 24-16d 2-10dx1 240 255 MIU3.56/18 16 3 17 2 26- ... 16d 2-10dx1 240 255 MIU3.56/20 16 3 19 2 28-16d ... 2-10dx1 240 255 MIU3.56/20 3 16 3 19 2 28- ...
 
Show page 94
Composite Lumber Connectors FACE MOUNT HANGERS STRUCTURAL COMPOSITE LUMBER Actual ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... (115) Roof (125) HU7 HU1.81/5 (Min) HU1.81/5 (Max) (Min) 14 14 1 6 2 12-16d 4- ... 10d ´1 480 575 1610 1850 2010 1390 1600 ... 1740 HU7 (Max) 1 1 1 6 2 16-16d 12-16d 16- ... 16d 8-10d ´1 4-10d ´1 6-10d ´1 960 1150 2145 2465 2680 1855 2135 ... 720 865 2145 2465 2680 1855 2135 2320 HUS1.81/10 14 16 16 1 8 5 5 2 2 3 30-16d ... 10-16d 2845 3000 4900 5045 5145 4355 5010 5145 ... HU9 (Min) 1 9 2 18-16d 6-10d ´1 720 865 2410 2775 3015 2090 2400 ... 2610 HU9 (Max) 1 9 2 24-16d 10-10d ´1 1200 1440 3215 3700 4020 2785 3200 ...
 
Show page 95
Composite Lumber Connectors FACE MOUNT HANGERS STRUCTURAL COMPOSITE LUMBER Actual ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... (115) Roof (125) 3 x 16 14 HU416 (Min) 3 13 2 20-16d 8-10d 1205 1445 ... 2680 3080 3350 HU416 (Max) 3 13 2 26-16d 12-10d 1810 2015 ... 3485 4005 4355 HGUS414 12 3 12 4 66-16d 22-16d 5380 5380 ... 10015 10015 10015 7890 8185 8380 14 HGUS414 12 3 12 4 66-16d 22-16d 5380 5380 14 ... 14 HHUS5.50/10 5 9 3 30-16d 10-16d 2855 3430 5190 5970 6490 4385 5040 5480 ... HGUS5.50/10 12 5 8 4 46-16d 16-16d 3630 3630 8780 ... 8940 8940 7510 7510 7510 HHUS5.50/10 5 9 3 30-16d 10-16d 2855 3430 5190 ...
 
Show page 101
102 Engineered Wood Structural Composite ... Lumber Connectors GLTV/HGLTV Heavy Duty Hangers EGQ High Capacity Hanger This product ... because of a) easier installation, b) higher loads, c) lower installed cost, or a ... combination of these features. SIMPSON Strong-Tie GLTV and HGLTV hangers are designed ... use with structural composite lumber headers, and may take heavy loads. The top ... located to prevent degradation of the header due to splitting of laminations. For ... heavy loads with a face-mount application, ... see the HGUS series. MATERIAL: Top flange 3 gauge; ... Stirrups 7 gauge FINISH: Simpson gray paint ALLOWABLE LOADS: For hanger ... heights exceeding the joist height, the allowable load is 0.50 of the ...
 
Show page 102
103 Engineered Wood Structural Composite ... Lumber Connectors LGU/MGU/HGU/HHGU High Capacity Girder Hangers CSC Ceiling ... an efficient sound barrier, and a one hour U.L. listed fire rating. Field-form the ... Weyerhaeuser, respectively. NEW! The GU hangers are a high-capacity girder hangers ... designed for situations where the header and joist are flush at top. This part ... placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast ... . See General Notes. Install with Simpsons SDS x2 screws, which are provided with ... act as a single unit. Multiple member headers may require additional fasteners at ... the hanger locations. The quantity and location ... Ga Model No. Fasteners Dimensions Min. Header Depth 3 ha Allowable Loads SPF/HF DF/SP ...
 
Show page 103
104 Engineered Wood Structural Composite ... Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL 1. Loads may not be ... loads are based on tests on solid wood headers. 2. Uplift loads are based on Douglas ... Fir, and have been increased 33% and 60% for wind or ... block wall. 4. When I-joist is used as header, all nails must be 10dx1 . 5. SCL, ... PSL and TimberStrand LSL. 6. I-joist headers with SPF flanges only support 755 lbs ( ... from 1 to 1 , use 0.85 of the I-joist header load. For flanges with thicknesses ... from 1 to 1 , use 0.75 of the I-joist header load. 8. See pages 99 to 103 for Code ... reference numbers. 9. Hangers sorted in order of recommended ... performance and installation value. 10. NAILS: 16d and 16d DPLX 0.162" dia. x 3 ...
 
Show page 105
106 Engineered Wood Structural Composite ... Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3, 4, 7 Allowable Loads 1, 4, 7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face LBV2.56/11.25 ITT311. ... 245 285 1450 1300 1435 1615 1200 1050 WI311.25 3 12 2 11 2 2 2-16d 2-10d ... ´1 2335 1950 2335 1765 1435 1 4-10d 2-10d 2-10d ´1 ITT311.88 18 2 11 2 ... 1 4-10d 2-10d 2-10d ´1 245 285 1450 1300 1435 1615 ... 1200 1050 MIT311.88 BA2.56/11.88 (Min) BA2.56/11 ... Max) WPI311.88 ITT313 18 2 12 2 1 4-10d 2-10d 2-10d ´1 245 285 1450 1300 1435 ... 1615 1200 1050 LBV2.56/13 ITT314 18 2 13 2 1 4- ... 10d 2-10d 2-10d ´1 245 285 1450 1300 1435 1615 1200 ...
 
Show page 106
107 Engineered Wood Structural Composite ... Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3, 4, 7 Allowable Loads 1, 4, 7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face HIT322 3 16 2 22 3 ... 2 4-16d 6-16d 2-10d ´1 240 290 2550 2050 2500 3050 ... .56/22 WPI322 3 12 2 22 2 2 2-16d 2-10d ´1 3635 3320 3635 3255 2600 2030 ... HWI322 3 11 2 22 4 2 4-16d 4-10d ´1 5100 4000 4500 5285 3665 ... HIT324 3 16 2 24 3 2 4-16d 6-16d 2-10d ´1 240 290 2550 2050 2500 3050 ... .56/24 WPI324 3 12 2 24 2 2 2-16d 2-10d ´1 3635 3320 3635 3255 2600 2030 ... HIT326 3 16 2 26 3 2 4-16d 6-16d 2-10d ´1 ... .56/26 WPI326 3 12 2 26 2 2 2-16d 2-10d ´1 3635 3320 3635 3255 2600 2030 ...
 
Show page 107
108 Engineered Wood Structural Composite ... Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3, 4, 7 Allowable Loads 1, 4, 7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face ITT49.25 18 3 9 2 ... 1 4-10d 2-10d 2-10d ´1 245 285 1450 1300 1435 1615 ... 1200 1050 14 3 9 2 2 6-16d 4-16d 2-10d ´1 ... 1495 14 3 9 2 2 6-16d 4-16d 2-10d ´1 2910 2885 3190 2590 1830 1495 14 ... 3 9 2 2 6-16d 4-16d 2-10d ´1 2910 2885 3190 2590 1830 1495 ... LBV3.56/9.25 HB3.56/9.25 WPI49.25 3 10 3 9 3 3 6-16d 16-16d 10-16d 2175 ... 2610 5815 5640 6395 5700 3820 3 10 3 9 3 3 6-16d 16-16d 10-16d 2175 ... 14 14 3 11 2 2 2 2 6-16d 4-16d 2-10d ´1 6-16d 4-16d 2-10d ´1 2910 2885 ...
 
Show page 108
109 Engineered Wood Structural Composite ... Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL 3 x 13 ITT413 18 3 12 ... 2 1 4-10d 2-10d 2-10d´1 245 285 1450 1300 1435 1615 1200 ... 1050 14 3 13 2 2 6-16d 4-16d 2-10d´1 ... 1495 14 3 18 2 2 6-16d 4-16d 2-10d´1 2910 2885 3190 2590 1830 1495 LBV3. ... 56/13 ITT414 18 3 13 2 1 4-10d 2-10d 2-10d´1 245 285 1450 1300 1435 ... 1615 1200 1050 MIT414 16 3 14 2 2 4-16d 4-16d 2 ... -10d´1 14 3 14 3 2 6-16d 10-16d 2-10d´1 3 14 3 14 3 2 6-16d 10-16d 8-10d´1 ... 14 3 16 3 2 6-16d 10-16d 2-10d´1 3 14 3 16 3 2 6-16d 10-16d 8-10d´1 ... 2115 2400 1665 1230 BA3.56/14 (Max) HB3.56/14 WPI414 3 10 3 14 3 3 6-16d 16-16d ...
 
Show page 109
Composite Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3,4,7 Allowable Loads 1,4,7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face DF/SP Actual DF/SCL 3 ... x 22 HIT422 16 3 22 3 2 4-16d 6-16d 2-10d´1 ... 2050 2500 3050 1950 LBV3.56/22 HB3.56/22 WPI422 12 3 22 2 2 2-16d 2-10d´1 ... .56/22 12 3 22 3 2 3-16d 4-16d 6-10d´1 485 485 4700 4880 4165 4165 ... HWI422 14 3 22 2 2 6-16d 4-16d 2-10d´1 2910 2885 3190 2590 1830 1495 3 10 ... 3 22 3 3 6-16d 16-16d 10-16d 2175 2610 5815 5640 6395 5700 ... 3820 3 14 3 24 2 2 6-16d 4-16d 2-10d´1 2910 2885 3190 2590 1830 1495 10 3 ... 24 3 3 6-16d 16-16d 10-16d 2175 2610 5815 5640 6395 5700 ...
 
Show page 110
Composite Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL See footnotes on page 104 ... .5-2 16 5 9 2 2 4-16d 4-16d 2-10d´1 240 290 2550 2140 2115 2400 1665 ... 9.5 WPI39.5-2 3 12 5 9 2 2 3-16d 2-10d´1 3635 3320 3650 3255 2600 2030 ... .12/11.25 14 11 2 2 6-16d 4-16d 2-10d´1 MIT311.88-2 16 5 11 2 2 4-16d 4 ... -16d 2-10d´1 240 290 2550 2140 2115 2400 1665 ... WPI311.88-2 3 12 5 11 2 2 3-16d 2-10d´1 3635 3320 3650 3255 2600 2030 5 ... 3,4,7 Allowable Loads 1,4,7 Solid Header 4 Joist Uplift (133) Uplift 160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face MIT3514-2 16 4 14 ... 2 2 4-16d 4-16d 2-10d´1 240 290 2550 2140 2115 2400 1665 1230 ... 14 4 14 2 2 6-16d 4-16d 2-10d´1 2910 2885 3190 2590 1830 1495 14 4 ...
 
Show page 111
Composite Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3,4,7 Allowable Loads 1,4,7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face DF/SP Actual DF/SCL ... 1370 1640 7500 7400 5750 7000 HGLTV5.50/18.75 3 7 5 18 6 2 6-16d 12-16d ... 6-16d 1370 1640 10500 7800 9000 8665 6690 4260 HB5.50/20 ... HWU5.50/20 3 10 5 20 3 2 4-16d 4-16d 6-10d 765 ... 1370 1640 7500 7400 5750 7000 HGLTV5.520 3 7 5 20 6 2 6-16d 12-16d 6-16d ... 1370 1640 10500 7800 9000 8665 HWU7.12/7.25 3 10 7 7 3 2 4-16d 4-16d 6- ... 10d 1020 1135 6000 5500 5535 6000 5415 ... HB7.12/9.25 B7.12/9.5 WPI49.25-2 3 12 7 9 2 ... 2 3-16d 2-10dx1 3635 3320 3650 3255 2600 2030 ...
 
Show page 112
Composite Lumber Connectors TOP FLANGE HANGERS I-JOISTS SCL Joist Size Model No. Web ... 3,4,7 Allowable Loads 1,4,7 Solid Header 4 Joist Uplift (133) Uplift (160) LVL ... LSL DF/SP SPF I-Joist 4 Masonry 3 W H B TF Top Face 7 x 14 B7.12/14 HB7. ... /14 WPI414-2 3 12 7 14 2 2 3-16d 2-10d´1 3635 3320 3650 3255 2600 2030 ... HWU7.12/14 3 10 7 14 3 2 4-16d 4-16d 6-10d 1020 ... 1370 1640 7500 7400 5750 7000 HGLTV414-2 3 7 7 14 6 2 6-16d 12-16d 6-16d ... 1370 1640 10500 7800 9000 8665 6690 4260 WMI414-2 ... 3 3 12 7 14 2 3 2-16dDPLX 2-10d 4175 7 x 16 B7.12/16 HB7.12/16 WPI416- ... 2 3 12 7 16 2 2 3-16d 2-10d´1 3635 3320 3650 3255 2600 2030 ... HWU7.12/16 3 10 7 16 3 2 4-16d 4-16d 6-10d 1020 ...
 
Show page 113
because of a) easier installation, b) higher loads, c) lower installed cost, or a ... /LSSU/LSSUI Light Slopeable/Skewable U Hangers for I-Joists and SCL 1. Roof loads are ... be factory-ordered. 4. Minimum 11 joist height for LSU3510-2, LSU4.12, LSU5.12; 9 for ... . 5. NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia ... Uplift (160) Uplift (133) Sloped Only Hangers Skewed Only or Sloped and Skewed ... Hangers Roof SPF Species Header Allowable Loads Snow (115) Const. (125 ... ) Uplift (133) Floor (100) Snow (115) Const. (125) Floor (100) ... Roof DF/SP Species Header Model No. Joist Width W Joist Face H A ... 2 2 2 2 1 1 1 1 3 2 2 2 2 10 10d 10 10d 10 10d 10 10d 18 16d 18 16d ...
 
Show page 116
Composite Lumber Connectors SUR/SUL/HSUR/HSUL Skewed 45 Hangers for I-Joist and ... SCL 1 x 9 -12 8 10-16d 1 x 10-16 1 x 9 9 1 x 11 11 1 x 14 2 x 11 11 ... 10 12-16d 11 11 13 2 x 9 -14 9 9 14-16d ... 2 -2 x 9 -14 9 14-16d 6-10dx1 6-10dx1 6-10dx1 6-10dx1 6-10dx1 8-10dx1 8- ... 10dx1 8-10dx1 8-10dx1 2 -2 x 14-20 13 18-16d 2 x 9 -14 8 ... /LI3514/20 SUR/L310 SUR/L314 SUR/L210-2 HSUR/L210-2 SUR/L214-2 HSUR/L214-2 SUR/L410 ... HSUR/L410 SUR/L414 HSUR/L414 16 16 3 3 3 3 3 3 3 3 3 3 3 3 3 3 ... 16 16 16 16 16 3 12-16d 16-16d 16-16d 2-10dx1 2-10dx1 2-10dx1 2-10dx1 12-10dx1 ... 10-10dx1 145 145 145 145 145 1595 2130 2500 ... 3 12 26-16d 1200 1250 1330 1530 1660 1040 1150 1320 1440 1440 1730 1595 1835 1995 ...
 
Show page 118
119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS Glulam Beam Double Shear Joist ... Hangers Carried Member Width Model No. Ga ... Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face ... Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow ... Roof Code Ref. (125) 3 GLULAM 3 GLULAM HU212-2 (Min) 14 3 10 2 2 16-16d 6-10d ... 905 1085 2145 2465 2680 1855 2135 2320 ... HU212-2 (Max) HU210-2 (Min) HU210-2 (Max) 3 10 2 22-16d 10-10d 1505 ... 2950 3390 3685 2550 2935 3190 HU3.25/10.5 3 10 2 22-16d 10-10d 1505 ... 2950 3390 3685 2550 2935 3190 HU3.25/12 3 11 2 24-16d 12-10d 1810 2015 ... 3215 3700 4020 2785 3200 3480 HU216-2 (Min) 3 13 2 20-16d 8-10d 1205 ...
 
Show page 119
120 Glulam Beam Connectors LGU/MGU/HGU/HHGU High Capacity Girder Hangers NEW! The ... GU hangers are a high-capacity girder hangers designed for situations where the ... header and joist are flush at top. This part ... placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast ... . See General Notes. Install with Simpsons SDS x2 screws, which are provided with ... act as a single unit. Multiple member headers may require additional fasteners at ... the hanger locations. The quantity and location ... Ga Model No. Fasteners Dimensions Min. Header Depth 3 ha Allowable Loads Face LGU3.25 ... 10 16-SDS x2 LGU5.25 10 16-SDS x2 Joist 12-SDS x2 12-SDS x2 ... W H 2 (min) 3 5 7 7 MGU5.25 10 24-SDS x2 16-SDS x2 5 8 Code Ref. ...
 
Show page 121
122 Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT Beam Glulam Saddle ... Hangers See table on page 123. See Hanger Options on page 188 for hanger ... may result in reduced loads. GLT and HGLT accommodate typical structural ... easy installation of beams. GLS and HGLS are heavy glulam saddle hangers. Tested ... tie provisions are added to the GLS or HGLS order GLST or HGLST. The seismic tie ... through the supporting member. Bolt holes shall be a minimum of to a maximum of ... : See table on page 123. FINISH: Simpson gray paint. Hot-dip galvanized ... available; specify HDG. INSTALLATION: Use all specified ... fasteners. See General Notes. GLT/HGLT All GLTs used with sawn timbers have a ... included. GLT may be attached to steel headers by x 2 fillet welds at each end of the ...
 
Show page 122
123 Glulam Beam Connectors TOP FLANGE HANGERS GLULAM BEAM Joist or Purlin Size Model ... Fasteners Allowable Loads W H B TF Header Joist Uplift (133) ... Uplift (160) Floor (100) Snow (115) Roof Code Ref. (125) 3 LAM ... 3 LAM GLT3 7 3 7 MIN 5 2 10-N54A 6-N54A 1455 1745 8165 8165 8165 ... HGLT3 7 3 7 MIN 6 2 18-N54A 6-N54A 1455 ... 6-N54A 6-N54A 1455 1745 9790 9965 10080 GLST3-5 8 7 3 9 MIN 6 5 6-N54A 6- ... 5 6 6-N54A 6-N54A 1455 1745 9840 10005 10115 GLST3-7 8 7 3 9 MIN 6 6 6- ... 5 8 6-N54A 6-N54A 1455 1745 9840 10005 10115 GLST3-9 8 7 3 9 MIN 6 8 6- ... 6-N54A 1455 1745 12465 12630 12740 HW3.25 11 3 5 MIN 4 2 4-10d 2-10d 5285 ... 5285 5285 HHB3 7 3 7 MIN 3 2 10-N54A 6-N54A 1455 1745 6105 6235 6235 ...
 
Show page 123
HCAs offer single-piece side plates, for ... fewer welds and higher horizontal loads. The Horizontal Load Table gives ... comparable HC models. MATERIAL: Side plates-7 gauge ... -see PT dimensions in table. FINISH: Simpson gray paint INSTALLATION: Use all ... fasteners. See General Notes. Bolt holes shall be a minimum of and a maximum of ... Download Table gives the basic HCA model with two rotation bolts. Contact ... Simpson for heights greater than 60". Position dia. ... allow for wood shrinkage. OPTIONS: The Horizontal Load Table gives other bolt options. To ... after the model name. Specify the H dimension. For dapped beams, reduce ... the H dimension by the PT dimension for each ...
 
Show page 125
because of a) easier installation, b) higher loads, c) lower installed cost, or a ... . 126 Plated Truss Connectors LUS/MUS/HUS/HHUS/HGUS Double Shear Joist Hangers 1 ... girder bottom chords, multiple ply hangers and on SPF/HF header wood species, ... see Technical Bulletin T-REDHEEL. 3. HGUS, HHUS and HGUQ hangers installed with ... bottom chords. See T-REDHEEL for HHUS and HGUQ allowable loads. 4. Allowable ... are based on the lowest joist fastener holes filled. For the LUS, fill the two ... lowest joist fasteners holes on the right side of the hanger and ... the single lowest joist fastener hole on the left side of the hanger. 5. ...
 
Show page 126
127 Plated Truss Connectors FACE MOUNT HANGERS 1. Uplift loads have been increased 33 ... (133) is a download rating. 3. Minimum heel height shown is required to achieve ... table loads. For less than minimum heel height, see Allowable Loads with ... Reduced Heel Height on page 126. 4. Truss chord cross-grain ... sizes and information. Model No. Min. Heel Height Ga Dimensions Fasteners Doug ... Pine Allowable Loads Spruce-Pine-Fir/Hem Fir Allowable Loads W H B Carrying ... Uplift 1 (133) Uplift 1 (160) Floor (100) Snow (115) Roof (125) Uplift 1 (133) ... Uplift 1 (160) Floor (100) Snow (115) Roof (125) Wind (133) Wind ... 16d LUS26-2 4 18 3 4 2 4-16d 4-16d HHUS26-2 4 14 3 5 3 14-16d 6-16d 1550 ... 1550 2580 2965 3225 1140 1165 1000 1150 1250 565 565 765 880 960 ...
 
Show page 127
128 Plated Truss Connectors HTU Face Mount Truss Hangers Standard ... Allowable Loads Maximum Hanger Gap) The new HTU face mount truss ... hangers have nail patterns designed specifically for ... shallow heel heights, so that full allowable loads (with ... minimum nailing) apply to heel heights as low as 3 ". Minimum and maximum ... options provide solutions for varying heel heights and end conditions. Alternate ... Notes. Can be installed filling round holes only, or filling round and triangle ... holes for maximum values. For single 2x ... carrying members, use N10 (10dx1 nails into the header and reduce the ... table value. The allowable uplift is 100% of the table load. See alternate ... for applications using the HTU28 or HTU210 on a 2x6 carrying member for additional ...
 
Show page 128
129 Plated Truss Connectors HTU Face Mount Truss Hangers HGUQ Multi-Ply ... Girder Truss Hangers See table footnotes on page 128. ... . Carrying Member Carried Member Floor (100) Snow (115) Roof (125) Wind (133) ... Uplift (133/ 160) Floor (100) Snow (115) Roof (125) Wind (133) ... Pine Allowable Loads Spruce-Pine-Fir/Hem Fir Allowable Loads Min. Heel Height W ... H B Code Ref. HTU26 (Min) 20-16d 14-10dx1 1175 2880 3100 ... 3100 3100 HTU26 (Max) 20-16d 20-10dx1 1215 2880 3290 3580 3760 HTU28 (Min) ... 26-16d 14-10dx1 1125 3720 3770 3770 3770 HTU28 (Max) ... 26-16d 26-10dx1 2140 3720 4275 4655 4965 HTU210 (Min ... ) 32-16d 14-10dx1 1250 3600 3600 3600 3600 HTU210 (Max) ... 32-16d 32-10dx1 3255 4575 5020 5020 5020 HTU26-2 (Min ...
 
Show page 148
and engineered wood products. MATERIAL: 10 gauge FINISH: Galvanized INSTALLATION: ... . See General Notes. OPTIONS: See Hanger Options, page 188. CODES: See page 12 ... for Code Listing Key Chart. H 5 " SIM PSON Strong -Tie SIMPSON ... Strong-Tie MBHA Typical MBHA Installation 5.MBHA ... hangers with height of 7 require a 3 minimum embedment of ... 3 or nail calculation values. 9. NAILS: 10d 0.148" dia. x 3" long. See page 16-17 ... . Model No. Fasteners Uplift 7 Uplift 7 Header 1 Joist (133) (160) (133) (160) Top ... Face MBHA 1-ATR x8 1-ATR x 8 18-10d 3145 3775 6050 3145 3475 5330 ... MBHA models with H 7 1-ATR x 8 1-ATR x 4 18-10d 1885 ... Down Load Model No. Dimensions W H MBHA3.56/7.25 MBHA3.56/9.25 MBHA3.56/11 ...
 
Show page 149
preassembled unit is riveted with no height adjustment. MATERIAL: HHETA-14 gauge; ... HETA-16 gauge; HETAL-strap 16 gauge, truss seat 18 gauge; META-18 ... . See General Notes. The META, HETA and HHETA are embedded 4" into a ... concrete beam or grouted block wall; HETAL is embedded 5 ". Do not drive nails ... for Code Listing Key Chart. Model No. H Uplift Load 133 Load Duration Increase ... META18 META20 6 META22 META24 META40 HETA16 12 HETA20 6 16 HETA24 20 HETA40 36 ... HHETA16 12 HHETA20 6 16 HHETA24 20 HHETA40 36 HETAL12 7 HETAL16 11 HETAL20 15 12 ... 14 16 18 20 36 META12 META14 HETA12 128 8, 62, 121, 128 8 10 8 128 8, 62, ... 121, 128 128 HHETA12 8 Lateral Loads (133 160) 10dx1 ...
 
Show page 159
160 Straps Ties FTA/LFTA Floor Tie Anchors T and L ... Strap Ties Typical L Installation Designed for use ... one FTA replaces two comparably sized holdowns and the threaded rod. The LFTA Light ... See table FINISH: LFTA-galvanized; FTA-Simpson gray paint INSTALLATION: Use all ... side opposite FTA for full loads. Nail holes between floors allow preattachment to ... are not required. OPTIONS: FTA may be hot-dip galvanized; specify HDG. The standard ... 2 2 3 3 1 2 2 3 3 LFTA 16 2 17 38 16-10d 1205 1400 FTA2 10 3 17 37 4 1575 ... 1890 2510 3120 3385 3385 FTA5 10 3 17 45 4 1865 2500 3125 3725 ... , 85, 121 20, 80, 124 1.Allowable loads have been increased 33% and 60% for ... penetrate wood less than 1 ". 3. NAILS: 10d 0.148" dia. x 3" long. See page 16-17 ...
 
Show page 162
163 Straps Ties H Seismic Hurricane Ties H4 Installation (H2.5 similar) (see ... footnote 3, page 142) H1 Installation H2 Installation H2.5 Installation (Nails ... into both top plates) H3 Installation (Nails into upper top ... plate) H4 Installation (Nails into upper top ... plate) H5 Installation (Nails into both top ... plates) H6 Stud to Top Plate Installation 9 8 7 1 ... 10 H5A Installation (Nails into both top ... plates) 11 12 2 3 H2.5A Installation (Nails into both top ... plates) 4 H2.5T Installation (Nails into both top ... plates) 5 H6 Stud to Band Joist Installation 13 1. ... Loads have been increased 33% and 60% for ... the same side of the plate (exception: H2.5A). 3. Allowable uplift load for stud to ...
 
Show page 163
164 Straps Ties H Seismic Hurricane Ties H10 Installation H10-2 Installation ( ... H11Z similar) 19 20 H14 Installation to double top plates 21 16 ... 18 Hurricane Tie Installations to Achieve Twice the ... each other for minimum 2x truss. For H2.5A only - Products can be on the same side ... 2x truss may cause the wood to split. H9 attaching truss to top plates 14 H7Z ... Installation H8 attaching stud to sill (4-8d into ... plate, 5-8d into stud) H8 attaching I-joist to double top ... plates H9, H10 and H10R optional positive angle nailing ... one time only. 17 Considerations for Hurricane Tie Selection 1. What is the uplift ... species of wood.) 5. Will the hurricane tie be nailed into both top plates or ...
 
Show page 164
Fasteners DF/SP Allowable Loads 1 SPF/HF Allowable Loads 1 To Rafters/Truss To ... ) (133) (160) F1 F2 (133) (160) F1 F2 HGA10KT 14 4-SDS x1 4-SDS x3 695 695 1165 ... 595 870 815 125 125 9, 62, 121 6, 121 HS24 18 8-8dx1 2-8d slant 8-8d 605 3 605 3 ... 645 3 1025 3 520 520 555 880 H15 16 4-10dx1 12-10dx1 12-10dx1 1300 1300 480 ... 1120 1120 410 H15-2 16 4-10dx1 4-10dx1 4-10dx1 1300 1300 480 1120 1120 410 ... H16 18 18 2-10dx1 2-10dx1 2-10dx1 2-10dx1 10-10dx1 10-10dx1 10-10dx1 ... 10-10dx1 1470 1470 1265 1265 1470 1470 1265 ... 1265 H16S H16-2 18 1470 1470 1265 1265 H16-2S 18 1470 ... 1470 1265 1265 Code Ref. The H16-2 series has a presloped seat of 5:12 for ...
 
Show page 170
171 Straps Ties A Angles and Z Clips L/LS/GA ... 1 (Total) Allowable Download (125) 2 W H B TF Z2 20 2 1 1 1 4-10dx1 465 ... 5 2 1 2-16d 485 Z28 28 2 1 1 1 10dx1 1 Z38 28 2 2 1 1 10dx1 1 Z44 12 ... 4, 37, 121 170 1. Z28 and Z38 do not have nail holes. Fastener quantities are as ... required. 2. Allowable loads have been increased 25% for roof loading (Z ... . 4. NAILS: 16d 0.162" dia. x 3 long, 10dx1 0.148" dia. x 1 long. See page 16-17 ... -Pine-Fir Allowable Loads 1 Floor (100) Snow (115) Floor (100) Snow (115) GA1 ... 2 4-10d 185 185 160 GA2 3 6-10d 335 385 335 L30 3 4-10d 220 240 ... 205 L50 5 6-10d 335 385 335 L70 7 8-10d 445 510 435 L90 9 10-10d 555 640 ... 480 160 335 205 360 475 600 LS30 3 6-10d 335 385 290 335 LS50 4 8-10d 450 ...
 
Show page 176
-Resistance, page 6-7. INSTALLATION: Holes are sized for 8dx1 ", 8d commons or #6 ... member. FBR24 and FBL24 are sized for 10dx1 ". CODES: See page 12 for Code Listing ... Model No. Ga Member Size Dimensions W H B FBL24 22 2x4 1 2 FB14 20 1x4 3 ... FB14 Louver Installation 1. FB26 has an allowable load for F1 of 365 lbs. 2 ... . FBR24 R rail (not rough). 3. NAILS: 10dx1 0.148" dia. x 1 long, 8d 0.131" dia. x ... and TA10ZKT include Z-MAX TA and HDG SDS x1 fasteners. CODES: See page 12 ... . Fasteners Allowable Download DF/SP (100) Stringer Tread TA9Z 2- 885 TA10Z 4- ... for tilt-up perimeter forming, the nail hole placement ensures substantial re-use. ... Shelving Solutions brings color to your home. Request Color Systems information on ... Notes. SBV Reversible for nominal 10" or 12" shelves of any thickness. CF-R ...
 
Show page 180
Wall Bracing J/JP Floor Beam Levelers Simpson Wall Bracing products offer effective ... roll, WB126C 12 pieces per roll, WB143C 10 pieces per roll. The RCWB features a ... rolled edge (the TWB has two rolled edges) for extra strength ... 11'-4" 9' 53 2-16d 1-8d WB143C 14'-3" 10' 45 2-16d 1-8d RCWB14 14'-2" 10' 45 2- ... 16d 1-8d TWB14 14'-2" 10' 45 2-16d 1-8d Code Ref. 5, 121 5, 121 5 ... , 121 6, 121 6, 86, 121 6 170 The WBC Handy Carry Carton is convenient to store, ... fasteners. See General Notes. Holes are provided for installation with 4- ... 10dx1 nails. Do not use J/JPs for dynamic ... jacking of structures, such as houses. CODES: See page 12 for Code Listing Key ... A Code Ref. llowable Bearing Loads (100) H (inches) (Min-Max) Threaded Rod ...
 
Show page 185
PRODUCTS GROUP ORNAMENTAL JOIST HANGER CONCEALED JOIST TIES 1.Center pin in ... three ways: with no routing of header/post or beam; a routed header/post, or ... and screws required. Screws require a hex head driver. Router end of beam for ... screw heads for flush installation. The joist/beam ... Dimensions Fasteners Allowable Loads H1 H2 SDS Pins (2 or 4 2 Uplift (133) ... Floor (100) Snow (115) Roof (125) DOUGLAS-FIR CJT3 ... 4x8 5 4 6 3 1050 1050 1050 CJT4 4x10 7 5 8 4 2440 2805 ... 2815 CJT5 4x12 8 7 10 5 3005 3455 3755 CJT6 4x12 10 8 ... 5 8 4 2440 2805 2900 CJT5 8 7 10 5 3005 3455 3755 CJT6 3 x9 3 x10 3 ... x12 3 x9 3 x9 3 x9 3 x11 10 8 12 6 3535 4065 4420 PSL CJT3 5 ...
 
Show page 186
PRODUCTS GROUP STANDOFF BASES HL HEAVY ANGLES GUSSETS Typical PBV6PC ... CPS4 (other sizes similar) 10d Nail 1" Diameter Typical CPS4 ... Installation CPS4 4x4 3 3 1 4-10d 4490 5195 CPS46 4x6 5 3 1 4-10d ... 4490 5865 CPS5 5x5 4 4 1 4-10d 4490 5865 CPS6 6x6 5 5 1 4-10d ... 4490 7745 CPS7 8x8 7 7 1 4-10d 4490 8315 PBV6PC 6" Dia 5 1 4-SDS ... X3 " 3800 9250 PBV10PC 10" Dia 9 1 4-SDS X3 " 3800 19225 Post or ... Column Size L W H Post Dimensions Fasteners Model No. ... to be designed by others, refer to Simpson Strong-Tie Anchor Systems catalog. ... for short term loading. 5. NAILS: 10d 0.148" dia. x 3" long. See page 16-17 ... 1,2,3,4 W1 W2 L D1 D2 D3 D4 Qty Dia HL33PC 7 3 2 1 2 2 HL35PC 7 3 5 1 2 2 ...
 
Show page 188
189 Hanger Options HANGER OPTIONS GENERAL NOTES This information ... applies only to the hangers manufactured by Simpson Strong-Tie and ... of these options on a single hanger have not been evaluated. In some cases, ... evaluate each connection, including header and joist limitations, before ... is performed using a standardized hanger test method. The joist in the test ... . For example, the sloped down hanger tests are assembled with a joist cut ... with three 8d common toenails. Header and other attached structural members ... assumed fixed in actual installations. Horizontal loads induced by sloped joists must be ... on the manufacturing process used. U, HU, HUTF, W and B hangers normally have ...
 
 
  Similar searches   simpson strong ties h 10 (68)
simpson strong tie (196)
simpson strong ties (196)
simpson strong tie connectors (195)
free catalog simpson strong tie (6)
simpson strong tie straps (63)
simpson strong tie rafter connectors (17)
simpson strong ties 825 (7)
simpson strong tie quik drive (9)
simpson strong tie quik drive screw (6)
simpson strong tie catalog (195)
simpson strong tie holdown (26)
3 simpson strong tie (178)
simpson strong tie concealed flange (11)
simpson strong tie ridge (9)
simpson strong tie ridge connector (9)
simpson strong tie post base (29)
simpson strong ties h1 (11)
simpson strong tie washer plate at wall (10)
simpson strong tie joint nails (11)
simpson strong ties hu212 (6)
simpson strong tie and screws (58)
simpson strong tie saddle (11)
simpson strong tie floor screws (27)
simpson strong tie connectors 2x4 (35)
simpson strong tie hdg screws (16)
simpson strong tie hdg screws 14 x 2 (7)
simpsons strong tie (196)
simpson strong tie truss connectors (56)
simpson strong tie straps for steel ... (12)
simpson strong tie concealed joist tie (13)



Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com