Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
strong tie wood to wood hangers in Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
4 Wood Construction Connectors ALPHABETICAL ... 194 SP, SPH Stud Plate Tie......168 SS Stud Shoe ....................174 ... Anchor Bolt ..........33-34 ST Strap Tie ..............155, 156 STC Roof Truss ... STCT Roof Truss Clip ........144 Steel Strong-Wall ......56-61 STHD Holdown .............. ... 42-43 StrapMate Strap Holder ....22 Strong-Wall Shearwall ..62-67 SUR/SUL Hanger..86, ... 116, 117 T Strap Tie .........160, 184-185 TAZ Staircase ... ......................... ..30 TP/TPA Tie Plate................182 TS Twist Strap ... 104-113, 121 WT Wedge Form Tie............23 www.strongtie.com ..........195 Z Clip ... 29 ATS Anchor Tiedown System ...........194 B Hanger......... ... Bearing Plate..........23, 183 BT Brick Tie .......................18 2 CB Column ... ................17 7 CJT Concealed Tie..............186 CMST Coiled Strap ............158 CMSTC ...

5 Wood Construction Connectors INTRODUCTION ... QUALITY POLICY 800-999-5099 www.strongtie.com Products are divided into fourteen ... Sawn Connectors 88-118 Engineered Wood Structural Composite Lumber Connectors ... -154 Masonry Connectors 155-171 Straps Ties 172-182 Miscellaneous 183-187 ... 188-193 Hanger Options The Simpson Strong-Tie Company was founded in Oakland, ... in 1914 and has been manufacturing wood-to-wood and wood-to-concrete connectors since ... 1956. Since then, Simpson Strong-Tie Company, Inc., has grown to be the ... of construction connectors and to expand to include a complete line of ... anchor systems products. The Simpson Strong-Tie Co., Inc. NO EQUAL program includes: ... sales team. In-house R D, and tool and die professionals. In-house ...

6 Wood Construction Connectors TABLE OF ... 26, 27 Girder Hangers ... 42-45 Tension Ties ... 150, 151 Wedge Form Ties ... 23 ANCHORS Floor Tie Anchors ... 35-45 Seismic Hurricane Ties ................ 162-164 CAPS BASES ... .............. 46-55 SHEARWALL Steel Strong-Wall ......................... ..... 56-61 ... Strong-Wall Shearwall................ ........ 62- ... 67 SOLID SAWN CONNECTORS Adjustable Hangers ......................... .... 82, 83 ... Concealed Joist Tie ......................... ........ 186 ... Face Mount Hangers ......................... ... 68-76 ... Rough Lumber Face Mount Hangers ........ 76 Sloped/Skewed Connectors ... ................ 82, 86 Top Flange Hangers ......................... .... 77-81 ... ENGINEERED WOOD STRUCTURAL COMPOSITE LUMBER CONNECTORS ...

10 Wood Construction Connectors NEW PRODUCTS ... H2.5Ts truncated design was developed to accommodate trusses with 2x4 bottom ... chords. The easy to install, five nail pattern is stronger ... loads than our popular H2.5 hurricane tie. Page 162-164 H2.5T Hurricane Tie The GU ... hangers are a high-capacity girder hanger ... where the header and joist are flush at top. This part can be used for retrofit on ... placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast ... LGU/MGU/HGU/HHGU High Capacity Girder Hangers The THGQ and THGQH hangers for multi- ... ply girder trusses use SDS screws to provide high load capacities and easier ... installation compared to bolts. Both models offer minimum and ... optional maximum fastener quantities to accommodate varying design needs. ...

14 Wood Construction Connectors IMPORTANT ... INFORMATION GENERAL NOTES a. Simpson Strong-Tie Co., Inc. reserves the right to change ... , bolts and nails may not be combined to achieve highest load value. 8d (0.131" ... be noted (for example 8dx1 ). Refer to page 16, 17, NDS (National Design ... conditions must be adjusted according to the code. In many cases, Simpson code ... , since the specific gravity of these wood species fall within the specific ... specific gravity for the different wood species as listed by NDS. For your ... PSL 750 psi 0.50 f. For face-mount hangers straight straps, use 0.86 of table ... loads for Spruce-Pine-Fir. g. Simpson Strong-Tie Co., Inc. will manufacture non-catalog ... ksi, respectively. h. All references to bolts or machine bolts (MBs) are for ...

15 Wood Construction Connectors IMPORTANT ... a. The allowable load is limited to the lowest of deflection, lowest test ... Uplift Design Lateral Parallel to Plate/Allowable Lateral Parallel to ... Plate Design Lateral Perpendicular to Plate/Allowable Lateral Perpendicular ... to Plate 1.0. c. Loads are based on the ... of load adjustments for fasteners into wood as specified by the code are as ... loading. e. Unless otherwise noted, wood shear is not considered in the loads ... given; reduce allowable loads when wood shear is limiting. Glulam 145 psi, LVL ... PSL 290 psi; E 1.3x10 6 psi. f. Simpson strongly recommends the following addition to ... drawings and specifications: Simpson Strong-Tie connectors are specifically required ... to meet the structural calculations of ...

16 Fasteners Quik Drive NAILS Strong-Tie nails and structural fasteners have ... shank design, and point configuration to ensure conformity to published values. ... pneumatic nail use, see Instructions to the Installer, page 14 and visit www. ... strongtie.com for technical bulletins. COMPARABLE ... ; SS10D 10d common; SS16D 16d common TO ORDER: Display Packages available for ... , N10DHDG, 10DHDG and 16DHDG nails. To order, specify: Nail Type Description ... Load Adjustment Factor Face Mount Hangers Straight Straps 16d common (0.162 x 3 ... optional nails used with face mount hangers and straight straps 1.10dx1 or 16dx2 ... for joist nails in double shear hangers (i.e. LUS, MUS, HUS, HHUS, HGUS). 2.Do ... and LSSU. 3.This table does not apply to specials (see Hanger Options), or steel ...

for short-term loading. 2. A mudsill on top of the GH is required to achieve the ... . Typical GH Installation GH A girder-to-foundation wall connection. MATERIAL: 12 gauge. ... . OPTIONS: For skewed and saddle hangers, see Hanger Options on page 188. ... for Code Listing Key Chart. GH Girder Hangers The UFP10 Retrofit Foundation Plate ... installation time in half. Designed to connect when the mudsill is offset from ... the foundation up to 2 or extended beyond the foundation up ... to ". The UFP may be used in place of the ... not achieve published loads. Refer to T-ANCHORSPEC for post-installed ... Key Chart. Model No. Max Spacing to replace Anchor Bolt or dia. Fasteners ... Allowable Load Parallel to Plate (133) Code Ref. Anchor Bolt Plate ...

L2 H1 H2 Beam Surface Post Surface Post Top Surface Uplift Lateral CAPS BC4 3 3 2 ... cap over the lally column and attach to the girder. CODES: See page 12 for Code ... of the bearing loads using Fc equal to 425 psi for SPF, 625 psi for DF and 700 ... must be detailed by the Designer to transfer tension loads between spliced ... the lally cap must be evenly loaded. 5. To achieve lateral loads, LCC pipe must be ... welded to the column with an fillet weld around ... BCS allows for the connection of 2-2xs to a 4x post or 3-2xs to a 6x post. Double ... through the beam into the post below to achieve the table loads BC: install ... do not provide adequate resistance to prevent members from rotating about ... therefore are not recommended for non top-supported installations (such as fences or ...

63 Shearwall STRONG-WALL SHEARWALL RAISED FLOOR (-RF) Raised ... designed and tested for installation on top of raised wood floor systems. All 2nd ... SDS screws pre-installed in both the top and bottom of the wall allow for fast ... installation to the top plate and floor framing elements. When ... , only the HUSC46 may be used with the Strong-Wall Shearwall for light duty door and ... headers. With face nailing closer to the center of the carrying member and ... Hanger tables. Application is limited to the HUSC46. See page 69 for details. ... of HUSC46 Naming Scheme: SW24x8-RF Strong-Wall Raised Floor Width (in.) Nominal Height ... be required for compression force from Strong-Wall above. See Structural Details available ... available for 1 subfloor. SW-TUD1KT STRONG-WALL SHEARWALL FOR 2nd FLOOR APPLICATIONS! ...

HUCQ Heavy Duty Joist Hangers 68 Solid Sawn Connectors The HUCQ ... series are heavy duty joist hangers that incorporate Simpsons SDS wood ... of a beam or on a post, they provide a strong connection with fewer fasteners than ... nailed hangers. See page 91 for structural composite ... lumber hangers. MATERIAL: 14 gauge FINISH: Galvanized ... screws supplied. For use on solid sawn wood members. CODES: See page 12 for Code ... 2.See page 91 for additional engineered wood products sizes. 3.When using structural ... lumber columns, screws must be applied to the wide face of the column. Uplift ( ... B H W See Hanger tables on pages 70 to 76. See Hanger Options on pages 188 for ... U hanger provides flexibility of joist to header installation. Versatile fastener ... models have triangle and round holes. To achieve maximum loads, fill both round ...

Connectors LUS/HUS Double Shear Joist Hangers LOAD TABLE EXPLANATION This product is ... preferable to similar connectors because of a) easier ... features. See Hanger tables on pages 70 to 76. See Hanger Options on pages 188 for ... which may result in reduced loads. All hangers in this series have double shear ... tabs.) MATERIAL: See tables, pages 70 to76. FINISH: Galvanized. Some products ... , page 6-7. Stainless steel (SS) hangers are available with SS nails-order ... the joist or truss into the header to achieve the table loads. Not designed ... into the joist, reduce the load to 0.64 of the table value. Use stainless ... steel (SS) nails with SS hangers. OPTIONS: LUS hangers cannot be modified ... . HUS hangers available with the header flanges ... similar) HUS412 Double Shear Nailing Top View Typical LUS28 Installation use . ...

70 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) CODES: See ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ... other nail sizes and information. * Hangers do not have an Installed Cost Index. B ...
72 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) Joist Size ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ... for other nail sizes and information. * Hangers do not have an Installed Cost Index. B ...
75 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 6. NAILS: 16d 0 ...
76 Solid Sawn Connectors FACE MOUNT HANGERS ROUGH LUMBER (DF SP) FACE MOUNT HANGERS ... rough sizes at full table loads. Add X to the model designation ex: HU28X and ...

77 Solid Sawn Connectors TOP FLANGE HANGERS JB/LB/BA/B/HHB Joist, Beam and Purlin ... Hangers HUTF/HUSTF Heavy Duty and Double Shear ... Joist Hangers NAILER TABLE This table also applies to ... sloped-seat hangers. B SERIES WITH VARIOUS HEADER ... normal deflection limit. Model Series Top Allowable Loads Header Type Fasteners ... or welded applications; see W and B hangers. HUTF The minimum header or ledger size ... Hanger Options on page 188 for skewed hangers. Available with flanges turned in (2-2x ... details. Typical BA Installation on Wood Nailer Typical BD Saddle Installation ... BA B (HHB Similar) Double Shear Nailing Top View HU410TF LB, BA, B and HHB are ... embossment provides added stiffness to the top flange. The newly improved B ... load capacities. See tables on pages 79 to 81. See Hanger Options on pages 188 and ...

78 Solid Sawn Connectors TOP FLANGE HANGERS W/WPU/WNP/WM/WMU/HW/HWU WM (WMU ... Allowable Loads Header Type Width Depth Top Face Joist Uplift (133 160) LVL PSL ... LSL DF/SP SPF I-Joist Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 ... Titens 2- x1 Titens 2- x1 Titens 9 to 28 6-10dx1 3380 3 to 30 3-10dx1 2- ... 485 4700 4880 3650 4165 4165 23 to 28 3-16d 4-16d 6-10dx1 315 4700 4880 ... 10dx1 5100 4000 4500 5285 3665 HWU 9 to 18 4-16d 4-16d 6-10dx1 810 6335 5500 ... 765 6335 5500 5535 6335 5415 23 to 28 4-16d 4-16d 6-10dx1 635 6335 5500 ... 1005 6335 5500 5535 6335 5415 9 to 18 4-16d 4-16d 6-10dx1 810 6000 5500 ... 26, 83, 124 1, 84, 140, 121 26, 124 1 to 4 1 to 4 1 to 7 1 to 7 4- x1 Titens ... 9 to 28 2-16d DPLX 6-10dx1 4175 1 to 7 1 to 7 1 to 7 1 to 7 1 to 7 1 to ...

82 This product is preferable to similar connectors because of a) easier ... Adjustable Light Slopeable/Skewable U Hangers This series attach joists or rafters to ... or down, and skewed left or right, up to 45 . MATERIAL: See table. FINISH: ... Listing Key Chart. STEP 1 Nail hanger to slope-cut carried member, installing ... skewed installation. STEP 2 Skew flange to form acute angle. Bend other flange ... one time only. STEP 3 Attach hanger to the carrying member, acute angle side ... 125) Snow (115) Const (125) Sloped Only Hangers LSU26 18 1 4 6-10d 5-10dx1 485 535 ... 2795 3035 2160 2485 2700 Skewed Hangers or Sloped and Skewed LSU26 18 1 4 6- ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 4.NAILS: 16d 0. ...

The HCP connects a rafter or joist to double top plates at a 45 angle. ... . See General Notes. Attach HCP to double top plates; birdsmouth not ... complete nailing. Rafter may be sloped to 45 . CODES: See page 12 for Code ... 1 Spruce-Pine-Fir Allowable Loads 1 To Rafters To Plates (133 160) (133 160) ... with factory. The VPA is adjustable to slopes between 3:12 and 12:12, ... reduces the need for beveled plates and toe-nailing. MATERIAL: 18 gauge FINISH: Galvanized ... hole. Hammer nail in at a slight angle to prevent splitting. STEP 1 Install top ... nails and face PAN nails in A flange to outside wall top plate. STEP 2 Seat ... with a hammer, adjusting B flange to the required pitch. STEP 3 Install B ... U.S. Patent 5,335,469 A and B flanges touch at 45 HCP2 (HCP4Z similar) U.S. Patent ...

HRC Hip Ridge Connectors PF Post Frame Hangers PFD26 (PFD24, PFDS26,PFD26L similar) U. ... Patent 5,104,252 PFD and PFA post frame hangers have double shear nailing to speed ... . Diamond holes on PFD allow optional top flange nailing. Double shear nailing ... for greater strength. OPTIONS: These hangers cannot be modified. CODES: See page 12 ... 895 955 1075 1130 955 1075 Code Ref. 1. To assure the table loads, the carried ... Allowable loads shown are for each hip. Total load carried by the connector is double ... diamond holes on HRC22 and HRC42 to secure the HRC. Bend face flanges on ... . HRC22 on face of ridge adjust to correct height and install nails. ... Double bevel-cut hip members to achieve full bearing capacity. The HRC ... may be sloped to 45 with no reduction in loads. CODES: ...

Connectors THA/THAC Adjustable Truss Hangers This product is preferable to similar ... code nailing and can be field-formed to give top flange hanger convenience. ... of 45 degrees. Straps can be formed to give top flange hanger convenience. PAN ... -Install all face nails according to the table. Nails used for the joist ... a minimum of 2 ". A minimum of four top and four face nails must be used. For ... the strap is field-formed over the top of the header a minimum of 1 for the ... for all others, and a minimum of four top and two face nails are used. CODES: ... 160) Floor (100) Snow (115) Roof (125) Top Face Straight Slant MINIMUM NAILING TOP ... 2-10dx1 1. 16d sinkers may be used to replace 16d commons at 0.85 of table ... except THA29) 4. THAR/L422 with 4-10d top nails and 2-10d face nails: When the ...

Connectors SUR/SUL/HSUR/HSUL Skewed 45 Hangers This product is preferable to similar ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 4. NAILS: 16d 0 ... (HSUR similar) Standardized 45 skewed hangers, angled slots direct nails to allow ... fasteners. See General Notes. These hangers will normally accommodate a 40 to 50 ... and 4x models only (see illustration). To order, add C (for concealed) to the ...

HF26N/F Panelized Construction Hangers Model No. Joist Size Dimensions ... . F26P Typical Panelized Roof System F hangers are only for panelized roof ... ,402 The HF24N, HF26N, HF34N and HF36N hangers are designed for panels or components ... member without nailing. F series panel hangers are engineered components for ... construction, it is acceptable to nail through the sheathing into the ... hangers top flange using on 10dx2 nail placed in ... the middle third of the top flange, no closer than from the back ... non-structural and does not contribute to the load. CODES: See page 12 for Code ... Slope (100 125) Valley Ridge Code Ref. Total MSC2 1 5 2 12 10-16d 18-10dx1 45 0 ... skewed 45 INSTALLATION: Distribute the total load evenly about the centerline to ... loading. Fasten all built-up members together as one unit. Net height will be ...

88 Engineered Wood Structural Composite Lumber Connectors ... GENERAL CONNECTOR INSTALLATION WOOD NAILERS Nailer Too Wide The loading may ... thickness. Correct Attachment Nailer Too Narrow A maximum mismatch of ² for ... normal installations is allowed. Nailer Too Thin or the wrong hanger for the ... application. Toe nailing causes squeaks and improper ... hanger installations. Do not toe nail I-joists before installing top ... flange or face mount hangers. DOUBLE SHEAR NAILING The nail is ... on each nail for greater strength. TOP FLANGE HANGERS IUS INSTALLATION ... SEQUENCE Flush Framing Top flange configuration and thickness of ... top flange need to be considered for flush frame ... uneven surfaces and squeaky floors. WOOD I-JOISTS SLOPED JOISTS For sloped ...

89 Engineered Wood Structural Composite Lumber Connectors ... GENERAL CONNECTOR INSTALLATION STRONG-DRIVE SCREW INSTALLATION FOR LVL POSITIVE ... . 45 o angle Nail at wrong angle Nail too long Use a 10dx1 nail (Simpson N10 HDG ... Hanger side flange supports joist top flange. Hangers provide some joist ... Hanger side flange is below the joist top flange. No web stiffener results in ... assemblies. Install with high-torque, low-speed drill (5 amp+). Do not over- ... C D 1.0. Increase as allowed per code to a maximum CD 1.33. This document uses ... 4", edge distance 1 ", spacing parallel to grain 4", spacing perpendicular to ... based on the capacity of the fasteners to transfer loads between plies. The ... the manufacturers literature. Simpson Strong-Drive Screw L1 T Assembly B1 3 1 " SDS x3 ...

90 This product is preferable to similar connectors because of a) easier ... of these features. Engineered Wood Structural Composite Lumber Connectors ... IUS/IUT/MIU I-Joist Hangers The improved IUS is now fully ... the advantages of the face mount and top mount hanger. Installation is fast with ... the Strong-Grip and Snap-In joist features along with ... easy-to-reach face nail locations and self-jigging ... locator tabs. The MIU series hangers are designed for commercial and high ... thickness for bend-tab application is 1 to 1 ". This constrains the member, ... helping to reduce squeaks resulting from joist ... two additional 10dx1 joist nails for a total uplift load of 480 lbs and 575 lbs (33 ... four additional 10dx1 joist nails for a total uplift load of 720 lbs and 865 lbs (33 ...

91 Engineered Wood Structural Composite Lumber Connectors ... FACE MOUNT HANGERS U/HU I-Joist Structural Composite ... Lumber Hangers FACE MOUNT HANGERS HUCQ/HUS/HHUS/HGUS Double Shear SCL ... Hangers HUS410 Typical HU7 Installation Typical ... See Hanger tables on pages 92 to 96. See Hanger Options on page 188 for ... may result in reduced loads. These hangers have the highest loads of any face ... mount hangers! All hangers in this series have double shear ... tabs) MATERIAL: See tables, pages 92 to 96. FINISH: Galvanized. Some products ... General Notes. Do not use double shear hangers with I-joists. Nails must be driven at ... the joist or truss into the header to achieve the table loads. Not designed ... into the joist, and reduce the load to 0.64 of the table value. Install HUCQs ...

97 Engineered Wood Structural Composite Lumber Connectors ... I-Joist Structural Composite Lumber Hangers 1. The W dimension should be ordered ... at to greater than the joist width. ... Options Fasteners Allowable Loads Top Face Joist Uplift (133) Uplift (160) DF ... criteria. 3. The minimum header depth to achieve the maximum nail configuration ... " 9 -14" 9 -14" 9 -14" 1 2 3 1 2 2 to 2 3 to 5 THAI222 THAI1.81/22 THAI3522 ... THAI322 2 1 2 3 1 2 2 3 to 5 2 9 8 8 9 9 9 8 9 22 22 21 ... long straps and can be field-formed to give height adjustability and top ... for all I-joists used with these hangers. When a total of 20 face nails are used ... nailing configuration is shown for top nailing installations. The strap must ... be field-formed over the top of the header by a minimum of 2 ". ...

98 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS ITT/MIT/HIT/ITTM Engineered Wood ... Products Hangers A dedicated range of Top Flange I-joist hangers meeting the ... . This constrains the I-joist, helping to reduce squeaks resulting from joist ... movement. Reduced embossing on the ITTs top flange, and the hanger height sized ... for bend-tab application is 1 to 1 ". MIT/HIT Patented Positive Angle ... feature is specifically designed for wood web I-joists when used with the MIT or ... material is not removed, but is used to channel and confine the path of the ... nail to the optimum angle. PAN minimizes ... from a better angle. ITTM masonry-to-wood connectors can be directly embedded ... block wall. It can also be installed on top of a masonry or concrete wall using ...

99 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS ITT/MIT/HIT/ITTM Engineered Wood ... Products Hangers OPTIONAL NAILING FOR INCREASED UPLIFT ... maximum allowable loads for ITT/MIT/HIT hangers used on wood nailers. The header nail ... increase allowed. Reduce according to the code for normal loading criteria ... -joist for additional nailing. 1. These hangers may deflect an additional at design ... Model Fasteners Allowable Uplift Loads Top Face Joist (133) (160) ITT 4-10dx1 ... Fasteners Allowable Loads Header Type Top Face Joist Uplift (133) Uplift (160) ... 10 MID-WALL INSTALLATION 10 TOP OF WALL INSTALLATION LSL DF/SP Masonry ... masonry screws are x1 . 3. Applies to LVL headers made primarily from Douglas ... . For flanges with thicknesses from 1 to 1 , use 0.85 of the I-joist header ...

100 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS LBV/BA/B/HB I-Joist Structural ... Composite Lumber Hangers LBV Model No. Nailer Header Nails ... . See main table for loads specific to actual widths. 3. Uplift loads have ... on DF/SP header species. 8. Applies to LVL headers made primarily from Douglas ... . For flanges with thicknesses from 1 to 1 , use 0.85 of the I-joist header ... . For flanges with thicknesses from1 to 1 , use 0.75 of the I-joist header ... Hanger Installation BA Installed LVL to LVL Max Nailing BA installed 2X nailer ... Fasteners Allowable Loads Header Type Top Face Joist Uplift (133) Uplift (160 ... allowable loads for BA, LBV, B, and HB hangers used on wood nailers. Nailers are wood ... members attached to the top of a steel I-beam, concrete or masonry ...

101 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS W/WP/WPU/WM/WMU/HW/HWI/HW U I-Joist ... Structural Composite Lumber Hangers 2 " WP/WPI NAILER TABLE Model Nailer ... Top Flange Nailing Allowable Loads DF/SP ... Loads Header Type Width Depth Top Face Joist Uplift (133 160) DF/SP ... DF/SCL I-Joist 5 Code Ref. Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 ... greater than 2") 26, 124 (widths up to 3 ") 26 124 26, 83 1, 84 1 to 4 3 to 30 ... 2-10dx1 2150 2020 2200 1435 1 to 4 3 to 30 2-16d 2-10dx1 2335 1950 ... 2335 1765 1435 WM 1 to 4 3 to 30 2-16d DPLX 2-10dx1 4175 WMU 1 to ... 7 9 to 28 6-10dx1 545 3380 1 to 7 9 to 28 2-16d DPLX 4- x1 Titens 4- ... 2- x1 Titens 6-10dx1 625 4175 1 to 7 3 to 30 3-10dx1 2-10dx1 2865 3250 ...

102 Engineered Wood Structural Composite Lumber Connectors ... GLTV/HGLTV Heavy Duty Hangers EGQ High Capacity Hanger This product ... is preferable to similar connectors because of a) easier ... combination of these features. SIMPSON Strong-Tie GLTV and HGLTV hangers are designed ... headers, and may take heavy loads. The top flange nails are sized and specifically ... located to prevent degradation of the header due ... to splitting of laminations. For heavy ... , see the HGUS series. MATERIAL: Top flange 3 gauge; Stirrups 7 gauge FINISH ... is a x 2 fillet weld at each end of the top flange for GLTV, and a x 2 fillet weld ... at each end of the top flange for HGLTV, see page 10 for weld ... loads listed. Uplift loads do not apply to this application. Web stiffeners are ... ledgers must be a minimum of 4x lumber to guarantee the load values given in the ...

103 Engineered Wood Structural Composite Lumber Connectors ... LGU/MGU/HGU/HHGU High Capacity Girder Hangers CSC Ceiling Support Clip /FSS Furring ... between the furring channel and joist to allow for the use of Thermafiber ... the attachment of the furring channel to all joists. Provides an efficient sound ... rating. Field-form the FSS with the CSC to prevent furring channel rotation ... channel must match dimensions shown to fit the CSC properly. U.L. listed. See ... Weyerhaeuser, respectively. NEW! The GU hangers are a high-capacity girder hangers ... where the header and joist are flush at top. This part can be used for retrofit on ... placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast ... All multiple members must be fastened together to act as a single unit. Multiple ...

104 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS I-JOISTS SCL 1. Loads may not be ... loads are based on tests on solid wood headers. 2. Uplift loads are based on ... . For flanges with thicknesses from 1 to 1 , use 0.85 of the I-joist header load ... . For flanges with thicknesses from 1 to 1 , use 0.75 of the I-joist header load ... . 8. See pages 99 to 103 for Code reference numbers. 9. ... Hangers sorted in order of recommended ... SP SPF I-Joist 4 Masonry 3 W H B TF Top Face 1 x 9 ITT29.25 18 1 9 2 1 4 ...

This product is preferable to similar connectors because of a) easier ... of these features. 114 Engineered Wood Structural Composite Lumber Connectors ... /LSSU/LSSUI Light Slopeable/Skewable U Hangers for I-Joists and SCL 1. Roof loads are ... Uplift (160) Uplift (133) Sloped Only Hangers Skewed Only or Sloped and Skewed ... Hangers Roof SPF Species Header Allowable Loads ... The LSU5.12 must be factoryskewed 0 to 45 . It may be fieldsloped to 45 . ( ... SEQUENCE STEP 1 Nail hanger to slope-cut carried member, installing ... skewed installation. STEP 2 Skew flange to form acute angle. Bend other flange ... one time only. STEP 3 Attach hanger to the carrying member, acute angle side ... . This series attach joists or rafters to headers, sloped up or down, and skewed ... left or right, up to 45 . MATERIAL: See table FINISH: ...

115 Engineered Wood Structural Composite Lumber Connectors ... , see page 116 The VPA is adjustable to slopes between 3:12 and 12:12, ... reduces the need for beveled plates and toe-nailing. MATERIAL: 18 gauge FINISH: Galvanized ... U.S. Patent 5,335,469 A and B flanges touch at 45 The HCP connects a rafter or ... joist to double top plates at a 45 angle. MATERIAL: 18 ... . See General Notes. Attach HCP to double top plates; birdsmouth not ... complete nailing. Rafter may be sloped to 45 . CODES: See page 12 for Code ... 1 Spruce-Pine-Fir Allowable Loads 1 To Rafters To Plates (133 160) (133 160) ... nail in at an approximate 45 angle to limit splitting. STEP 1 Install top ... nails and face PAN nails in A flange to outside wall top plate. STEP 2 Seat ... with a hammer, adjusting B flange to the required pitch. STEP 3 Install B ...

Cut Joist (HSUR similar) 116 Engineered Wood Structural Composite Lumber Connectors ... Hip Ridge Connectors For complementary top plate connection, see page 115 SUR/SUL/ ... HSUR/HSUL Skewed 45 Hangers for I-Joist and SCL HSUR SUL2.56/11 ... end of ridge-use optional diamond holes to secure the HRC. Bend face flanges back ... nailing. On face of ridge-adjust to correct height and install nails. ... Double bevel-cut hip members to achieve full bearing capacity. The HRC ... may be sloped to 45 with no reduction in loads. CODES: ... Allowable loads shown are for each hip. Total load carried by the connector is double ... , 4.75 and 5.12 are improved 45 skewed hangers designed specifically to ease the ... and double I-Joists. In addition to Positive Angle Nailing these hangers ...

119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS Glulam Beam Double Shear Joist ... Hangers Carried Member Width Model No. Ga ... models have triangle and round holes. To achieve maximum loads, fill both round ... triangle holes with common nails. HGUS hangers have the highest loads of any face ... mount hangers! All hangers in this series have double shear ... the joist or truss into the header to achieve the table loads. Not designed ... into the joist, and reduce the load to 0.64 of the table value. OPTIONS: HU ... hangers available with the header flanges ... Flanges Double Shear Nailing Top View Dome Double Shear Nailing Side ...

LGU/MGU/HGU/HHGU High Capacity Girder Hangers NEW! The GU hangers are a high-capacity ... girder hangers designed for situations where the ... header and joist are flush at top. This part can be used for retrofit on ... placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast ... All multiple members must be fastened together to act as a single unit. Multiple ... shear capacity of the carried member to make sure it matches the hangers ... header is based on the size necessary to fit screw pattern. Use the next size up ...

" WNP2.6 and WNP3.3 WPU Model Nailer Top Flange Nailing Allowable Loads DF/SP ... 3375 The WPU, HWU and HW series purlin hangers offer the greatest design flexibility ... . MATERIAL: WNP/WPI/WPU 7 ga. top flange, 12 ga. stirrup; HW 3 ga. top ... flange, 11 ga. stirrup; HWU 3 ga. top flange, 10 ga, stirrup. FINISH: Simpson ... 0.50 of the table load. INSTALLATION: Hangers may be welded to steel headers with for ... welds located at each end of the top flange. Weld-on applications produce ... information. Uplift loads do not apply to this application. Hangers can support ... the individual members must be secured together to work as a single unit before ... Loads Header Type Width Depth Top Face Joist Uplift (133 160) LVL PSL ... DF/SP SPF I-Joist Masonry Code Ref. 1 to 7 3 to 30 3-10dx1 2-10dx1 2865 ...

122 Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT Beam Glulam Saddle ... Hangers See table on page 123. See Hanger ... for timber and glulam beams. GLT top flange depth allows installation on ... . GLS and HGLS are heavy glulam saddle hangers. Tested and code-listed seismic tie ... provisions are added to the GLS or HGLS order GLST or HGLST. ... The seismic tie models use three extra bolts through ... . Bolt holes shall be a minimum of to a maximum of larger than the bolt ... are included. GLT may be attached to steel headers by x 2 fillet welds at ... each end of the header angle to obtain the tabulated loads. HGLT may be ... attached to steel headers by x 2 fillet welds at ... each end of the header angle to obtain the lesser of the tabulated ... 12,000 lbs. Uplift loads do not apply to this weld-on application. See page 10 ...

Connectors THA/THAC Adjustable Truss Hangers This product is preferable to similar ... 160) Floor (100) Snow (115) Roof (125) Top Face Straight Slant MINIMUM NAILING ... TOP FLANGE 2x4 THA29 18 1 9 5 4-10d 4- ... ,121,129,140 1. 16d sinkers may be used to replace 16d commons at 0.85 of table ... Nailing Installation 5. For single 4x2 top chord carrying members, THA 4x hangers ... with 10dx1 nails and a reduced load to 0.83 of the table value. Loads are ... full nailing and can be field-formed to give top flange hanger convenience. ... -Install all face nails according to the table. Nails used for the joist ... a minimum of 2 ". A minimum of four top and four face nails must be used. For ... the strap is field-formed over the top of the header a minimum of 1 for the ...

This product is preferable to similar connectors because of a) easier ... /MUS/HUS/HHUS/HGUS Double Shear Joist Hangers 1. Allowable loads shown consider ANSI ... girder bottom chords, multiple ply hangers and on SPF/HF header wood species, ... T-REDHEEL. 3. HGUS, HHUS and HGUQ hangers installed with the joist fastener ... HHUS similar) B MUS28 (Truss Designer to provide fastener quantity for ... connecting multiple members together) MUS completes the Simpson Strong-Tie ... line of face mount truss to truss connectors. The MUS has ... load capacity and bearing compared to LUS connectors for medium load truss ... applications. All hangers in this series have double shear ... the joist or truss into the header to achieve the table loads. Not designed ...

127 Plated Truss Connectors FACE MOUNT HANGERS 1. Uplift loads have been increased 33 ... . Minimum heel height shown is required to achieve full table loads. For less than ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 5. Loads shown ...
Truss Connectors HTU Face Mount Truss Hangers Standard Allowable Loads Maximum Hanger ... Gap) The new HTU face mount truss hangers have nail patterns designed ... loads (with minimum nailing) apply to heel heights as low as 3 ". Minimum and ... and reduce the allowable download to 0.70 of the table value. The allowable ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 8. Loads shown ...

Truss Connectors HTU Face Mount Truss Hangers HGUQ Multi-Ply Girder Truss Hangers See ... may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF, T- ... loads that consider ANSI/TPI 1 wood member design criteria. 4.Strong-Drive ... screws are permitted to be installed through metal truss ... are met (pre-drilling required). HGUQ hangers are designed for connections to multi- ... . Installation using Simpsons SDS wood screws will provide an improved ... faster and easier installation compared to nails. MATERIAL: 12 gauge FINISH: ... (header and joist). OPTIONS: These hangers cannot be modified. CODES: See page 12 ...

W WP MATERIAL: W, WM 12 gauge top flange and stirrup, WP 7 gauge top ... : Use all specified fasteners. Hangers may be welded to steel headers with for ... fillet welds located at each end of the top flange. Weld-on applications produce ... load listed. Uplift loads do not apply to this application. Hangers can support ... the individual members must be secured together to work as a single unit before ... nail pattern which relocates the nails to the bottom of the joist. OPTIONS: See ... cantilever construction. Model Nailer Top Flange Nailing Allowable Loads DF/SP ... Loads Header Type Width 4 Depth Top Face Joist LVL PSL LSL DF/SP SPF ... Code Ref. I-Joist Masonry W 1 to 3 3 to 30 2-10dx1 2-10dx1 1635 1740 1600 ... 1415 1 to 3 3 to 30 2-10d 2-10dx1 2150 2020 2200 ...

Truss Connectors THAR/L422 Skewed Truss Hangers Typical THASL218 Installation (L in ... (100) Snow (115) Roof Code Ref. (125) Top Face Straight FACTORY SKEW 45 O 2x ... 365 1260 1260 1260 FIELD SKEW 46 O TO 84 O 2x Truss THASR/L218 1 18 5 4-10d ... . STEP 3 Adjust acute side of hanger to the desired angle. STEP 4 Adjust obtuse ... on obtuse side. Field skewable from 46 to 84 . No special order needed. MATERIAL ... of 45 degrees. Straps must be bent for top flange installation. PAN nailing helps ... : Maximum Nailing A minimum of four top and 12 face nails must be used. Straps ... . Minimum Nailing A minimum of four top and 2 face nails must be used. Straps ... members, use 10dx1 nails and refer to the table for reduced loads. CODES: See ... Chart. Typical THAL422 installed on 4x2 wood truss. THAL422 Top Face Straight ...

for jack trusses. Adjustable from 0 to 67.5 degree (shipped with 67.5 degree ... triangle holes for maximum values. To reduce the potential for splitting, ... with the bend line. Bend the TJC37 to the desired position (one bend cycle ... involving attachment of TJC37 to the top chord requires minimium 2x6 carrying ... member for jack truss pitches up to 7:12, and 2x8 or larger for pitches ... See page 12 for Code Listing Key Chart. Top View Installation TJC37 Model No. ... and information. LTHMA Multiple Truss Hangers A single-piece connector designed to ... fasteners. See General Notes. The total load must be symmetrically distributed ... about the centerline to avoid eccentric loading of the ... /So. Pine Allowable Loads Header Hips (total) Jack Uplift (133 160) Floor (100) ...

Truss Connectors LTHJ Truss Hip/Jack Hangers Single piece, non-welded truss hip/jack ... All multiple members must be fastened together to act as a single unit. The two 10d ... be more than " from the back plate to meet required nail penetration. Should ... be attached to a double girder truss to allow for code-required minimum nail ... penetration. Distribute 75% of the total load to the hip member. With single 2x ... nails and use 0.82 of the table value. TO ORDER: Specify LTHJL for left 45 skewed ... AND/OR SKEW Available in hip slopes up to 45 and/or skews left or right from 46 ... to 67 . For optional configurations, ... loads are 100% of table loads. To order, specify degree of slope and/or ... skew left or right. Example: To order an LTHJ sloped down 45 and ... 475 475 215 215 330 380 410 410 Total 735 830 1515 1745 1895 1900 630 ...

Jack Girders This product is preferable to similar connectors because of a) easier ... -Pine-Fir Allowable Loads Model No. Total Avg Ult Fasteners 47, 134 The ... . Consult with truss engineer or refer to Truss Engineering for actual demand ... All multiple members must be fastened together to act as a single unit. Should be ... attached to a double girder truss to allow for required minimum nail ... and jack combinations, distribute 65% to 85% of the total load to the hip ... seat for table loads. OPTIONS: These hangers can not be modified. CODES: See page 12 ... chord, multiply the down load by 0.50. Top View Left Hand Hip Installation Top ... Terminal Hip without Center Common Jack Top View Right Hand Hip Installation Top ... View Left Hand Hip Installation Top View Terminal Hip without Center Common ...

Allowable Loads Carrying Member Hips (total) Jack Uplift (133 160) Floor (100) Snow ... (115) Roof (125/133/160) Hip Jack Total Hip Jack Total Hip Jack Total Hip Jack ... Total Code Ref. MTHM 2 ply 2x4 22-16d 16- ... Allowable Loads Carrying Member Hips (total) Jack Uplift (133 160) Floor (100) ... Snow (115) Roof (125/133/160) Hip Jack Total Hip Jack Total Hip Jack Total Hip Jack ... Total MTHM 2 ply 2x4 22-16d 16-10dx1 4- ... 5310 2125 1060 5310 Code Ref. MTHM Top View Left Hand Hip Installation Model ... Snow (115) Roof (125/133/160) Hip Jack Total Hip Jack Total Hip Jack Total Hip Jack ... Total MTHM 2 ply 2x4 22-16d 8-10dx1 4- ... Snow (115) Roof (125/133/160) Hip Jack Total Hip Jack Total Hip Jack Total Hip Jack ... Total MTHM 2 ply 2x4 22-16d 8-10dx1 4- ...

MSCPT2-2 MSCPT2 MSCPT2 Top View (MSCPT2-2 similar) MSCPT2N Top ... /Roof/Wind (100/115/125/133) Hip Jack Total Hip Jack Total MSCPT2 1 5 2 26- ... Header Joists Uplift (133/160) Hip Jack Total Hip Jack Total MSCPT2 1 5 2 26-16d ... models, allowable hip loads are 0.40 x Total Loads, and Jack Loads are 0.20 x Total ... . The MSCPT is a welded hanger designed to carry up to three trusses intersecting ... into a double ply girder truss. The top flange is notched at the center to ... members in the girder truss. MATERIAL: Top flange-3 gauge; stirrup-11 gauge ( ... fasteners. See General Notes. The total load must be evenly distributed about ... the centerline to avoid eccentric loading. All multiple ... members must be fastened together to act as a single unit. Minimum ...

NEW! The THGQ and THGQH hangers for multi-ply girder trusses use SDS ... screws to provide high load capacities and ... easier installation compared to bolts. Both models offer minimum and ... optional maximum fastener quantities to accommodate varying design needs. ... All multiple members must be fastened together to act as a single unit. Girders must ... be adequately laterally braced to prevent excessive displacement due to ... secondary torsional stresses (Ref ANSI/TPI 1-2002 Section ... centered on girder vertical webs. 4. Strong-Drive screws are permitted to be installed ... Connectors THGQ/THGQH Truss Girder Hangers ...

SIMPSON Strong-Tie Typical THGB2 Installation Model No. ... corresponding uplift (see footnote 1). To achieve maximum uplift, install nails ... and optional installation with the SDS Strong-Drive screw. MATERIAL: 3 gauge FINISH: ... All multiple members must be fastened together to act as a single unit. Maximum 11 ... bottom chord in the carrying member to allow for the minimum bolt end ... Connectors THGB/THGBH/THGW Truss Girder Hangers ...

Installation Method 1 Top Chord Installation Method 2 Vertical ... , request T-SDSCREWAPPS. The use of Strong-Drive screws insures that loads are ... not uniformly distribute applied loads to both trusses.) In addition differential ... sheathing shall be screwed (or nailed) to each truss top chord. (Fastener spacing ... Code requirements, or 12" o.c. max.) 4. Strong-Drive screws shall be installed with the ... spacing of 2x the required spacing, not to exceed 24" o.c. Offset the additional ... screws from the existing screws to prevent splitting. 5. Strong-Drive ... screws are permitted to be installed through metal truss plates ... applied load(s) and the location of the Strong-Drive screws. 7. The Truss Designer shall ... design all trusses and the truss system to meet all Code and ANSI-TPI requirements ...

2001 NDS. 3. Loads are based on 1 thick wood side members and apply to 3 and 4 ply ... 2x wood truss applications. (Side and main ... members of same wood species.) Contact Simpson for other ... applications. Simpson Strong-Drive Screw U.S. Patent 6,109,850 Other ... , request T-SDSCREWAPPS. 1. Install Strong-Drive screws a minimum of 1 inch into the ... adequate lateral bracing is provided to prevent displacement of the truss and ... the truss bottom chord due to the torsion created by the structural members ... of the multi-ply girder truss. 5. If Strong-Drive Screws are installed in the wrong truss ... spacing of 2x the required spacing, not to exceed 24" o.c. Offset the additional ... screws from the existing screws to prevent splitting. 6. Do not install ... Strong-Drive Screws through metal truss plates ...

Connectors TITEN Screws WM/WMI/WMU Hangers Model Joist Fasteners Masonry ... Allowable Loads W H Top Face Joist Uplift (133 160) Download ( ... 100/115/125) 1 to 7 3 to 30 2-16d DPLX 2-10dx1 WMU 1 to 7 9 ... to 28 2-16d DPLX 4- x1 Titen 6-10dx1 625 ... construction. 2. Titen x1 installed on top of wall after grout has cured. 3. Mid- ... course above and below the hanger. 4. Top of Wall Installation. 5. NAILS: 16d ... WMU Mid-Wall Installation WMU Top of Wall Installation See pages 104-113 ... on pages 104-113; WM, WMI, WMU 12 ga. top flange and stirrup FINISH: Simpson gray ... nails must be installed into the top flange and embedded into the grouted ... course above and one course below the top flange with one #5 vertical rebar ... is 2000 psi. When installed on top of masonry wall, use 2-Titen x1 ...

148 Masonry Connectors HU/HUC/HSUR/L Hangers Down (133) (160) (100/115/125) HU26 4 ... are heavy duty face mount joist hangers made from 14 gauge galvanized steel. ... version of the HU. Concealed flange hangers have the face flanges turned in. HU ... T-HUHUCTTN. INSTALLATION: These hangers are attached to grouted CMU walls using ... not provided. Drill the diameter hole to the specified embedment depth plus ". ... Alternatively, drill the diameter hole to the specified embedment depth and blow ... reduce the anchors load capacity. The hangers should be installed such that a minimum ...

for solid sawn, truss and engineered wood products. MATERIAL: 10 gauge FINISH: ... Code Listing Key Chart. H 5 " SIM PSON Strong -Tie SIMPSON Strong-Tie MBHA ... Typical MBHA Installation 5.MBHA hangers with height of 7 require a 3 minimum ... of the face bolt using ET22 Epoxy-Tie. All thread rods and/or machine bolts to ... better. 6.Additional anchorage products to be designed by others. 7.Uplift loads ... 1 Joist (133) (160) (133) (160) Top Face MBHA 1-ATR x8 1-ATR x 8 18-10d ... installation using Simpson ET22 Epoxy-Tie 6 minimum embedment required. All ... thread rods and/or machine bolts to be diameter x 8" long, grade A307 or ... better. Refer to the Anchoring Systems catalog. 1. ... 415 149 Masonry Connectors MBHA Masonry Hangers ...

The HRS, a heavy 12 gauge strap tie, provides greater support in ... a lower nailing profile. Install Strap Ties where plates or soles are cut, at wall ... intersections, and as ridge ties. LSTA and MSTA straps are engineered for ... use on 1 members. The 3" center-to-center nail spacing reduces the possibility of ... fasteners used. The LSTI light strap ties are suitable where gun-nailing is ... necessary through diaphragm decking and wood chord open web trusses. L MSTI MST LSTI ... . OPTIONS: Special sizes can be made to order. Contact factory. CODES: See page ... reinforcing cut members (16 gauge) at top plate and RPS at sill plate. ... Code 2000/2003 2308.9.8 (For RPS, refer to page 174.) MSTC28 Typical HRS ... shown) LSTI similar HRS 155 Straps Ties HRS/ST/FHA/PS/HST/LSTA/LS TI/MST/MSTA/ ...

156 Straps Ties HRS/ST/FHA/PS/HST/LSTA/LS TI/MST/MSTA/ ... MSTC/MSTI Strap Ties Model No. Ga Dimensions Fasteners ( ... Total) W L Nails LSTA9 20 1 9 8-10d LSTA12 1 ... increase on the steel capacity. Refer to page 13 for further explanation. 2. ... nails in each member being connected to achieve the listed loads. 6. PS strap ... both perpendicular and parallel-to-grain. Hole diameter in the part may be ... oversized to accommodate the HDG. Designer must ... . 7. For overlap splice details, refer to T-CMST. 8. Straps with 10d (0.148 dia. ...

increase on the steel capacity. Refer to page 13 for further explanation. 2.10d ... bolt loads are based on parallel-tograin loading and these minimum member ... nails in each member being connected to achieve the listed loads. 6.For overlap ... splice details, refer to T-CMST. 7. Straps with 10d (0.148 dia. ... . Model No. Ga Dimensions Fasteners (Total) W L Nails Qty Dia (133) (160) ( ... Allowable Tension Loads (SPF/HF) Floor-to-Floor Clear Span Table Model No. Clear Span ... Fasteners (Total) Allowable Tension Loads (DF/SP) (133 ... required in the rim board area. Floor-to-Floor Tie Installation showing a Clear ... with factory. A high value seismic tie for horizontal ties across intervening ... Key Chart. Model No. Strap Section L Total Fasteners Allowable Horizontal Loads ...

straps for retrofit applications to strap horizontal wood members together ... -Simpson gray paint OPTIONS: Where wood is subject to shrinkage, order an HCST2 ... for Code Listing Key Chart. Fasteners (Total) Model No. Allowable Loads Qty Dia (133 ... shown Model No. Tube Thickness Total Length L L2 No. and Size of Fasteners ... 45, 106, 126 PCT Installed in Pairs (Top View) 1.Allowable loads have been ... General Notes. PCT18 and 23 are sized to span a maximum hanger seat depth B ... ) of 4". PCT27 and 38 are sized to span a maximum hanger seat depth B ... , through the purlin. Offset angle to allow drilling access through glulam. ... for Code Listing Key Chart. 161 Straps Ties PCT Purlin Cross Tie ...

166 Straps Ties LTS/MTS/HTS Twist Straps HH Header ... Hangers Twist straps provide a tension ... connection between two wood members. They resist uplift at the heel ... at the transition points between wood members. MATERIAL: LTS-18 gauge; MTS- ... of the fasteners on each end of strap to achieve full loads. 3.Loads have been ... MTS Installation as a Truss-to- Top Plate Tie 1" TYP . L 1 " MTS30C ( ... the strap. 5.Twist straps do not have to be wrapped over the truss to achieve ... other cross member details. HH header hangers can speed up the job, strengthen the ... 88, 121 1. F1 Loads may be increased up to 25% for short-term loading in ...

Top Face Top Face S/JCT (min) 1- #10 2- #10 4- #10 ... Code Ref. Fasteners Steel Header Joist Wood Header Joist Welded Hanger x 2 fillet ... weld to each side of top Straight Hanger Straight Hanger Skew ... 16 gauge steel. 2. Allowable loads for wood headers are based on on 4x10 minimum ... 0.50. 3. Steel header must be braced to prevent web buckling per Designer ... ) S/HJCT Installation with a 4x10 wood header (others similar) S/JCT8-14 ... New improved higher load capacity joist hangers. Additional fasteners in the new S/JCT ... for use with C-Joists from 8" to 14" deep. For higher capacity joist ... hangers see S/JCT and S/HJCT. Joists can be ... from either side, or doubled up. These hangers can be used with either steel or wood ... easy installation. Field skewable up to 45 o left or right. MATERIAL: S/JCT8-14 ...

Dia (133) Tension/Uplift (160) STRAP TIES OS 12 2 12 4 1305 1565 OHS 7 2 12 ... or wind loading and apply only to continuous beams; reduce for other ... limiting. 3. Post sides are assumed to lie in the same vertical plane as the ... for other load durations according to the code provided they do not exceed ... beam sizes are available. Add an X to the name and specify width, i.e. OU68X ... 2050 2050 4765 Code Ref. 170 JOIST HANGERS Model No. Dimensions Bolts Ga W2 Qty ... OS and OHS loads are based on parallel-to-grain loading and a minimum member thickness ...

. Allowable loads are based on parallel-to-grain loading and a minimum member thickness ... bolts parallel and perpendicular to grain. Typical HTPC Installation ( ... page 50 for glulam beam sizes. Add PC to the model, i.e. CB5-6PC COLUMN BASES ... do not provide adequate resistance to prevent members from rotating about ... therefore are not recommended for non top-supported installations (such as fences or ... Dimensions Bolts Header Joist Without Top Flange No Triangle Theory Triangle ... . 3. Glulam widths listed in table. To specify other widths add an X to the ... information on these products. BEAM HANGERS MATERIAL: Top flange-7 ga, Stirrups-7 ... loads govern. 2. Post sides are assumed to lie in the same vertical plane as the ... determined using Fc perpendicular equal to 625 psi on seat area; reduce where end ...

ORNAMENTAL JOIST HANGER CONCEALED JOIST TIES 1.Center pin in beam. Short pin (2 for ... . The joist/beam may be sloped to 45 with full table loads. To provide ... similar) The OHU Ornamental Joist Hangers are heavy duty, load-rated joist ... hangers that are attached with Simpson x3 SDS ... yellow zinc finish wood screws (supplied with product). ... Size Model No. W H B No. of SDS x3 Wood Screws Douglas Fir Spruce Pine Fir ... beam must be installed perpendicular to the support member. The connections ...
Slopeable Slopeable Skewable Sloped Top Flange Open Top Flange Closed Top ... Flange Offset Top Flange Saddle Hanger Ridge Hanger ... is for down slope only. 6. Refer to page 63 for loads. 7. For U and HU type ... hangers, bevel or square cut available up to 50 ... flange concealed). HEIGHT FOR SLOPED HANGERS: Height 1 (H1) is the joist height ... in continuously dry conditions. Simpson Strong-Tie will calculate the Net H dimension ...

NOTES This information applies only to the hangers manufactured by Simpson ... Strong-Tie and installed per our instructions. ... with a joist cut on the lower end to lie flush with a wood member attached ... with three 8d common toenails. Header and other attached structural ... process used. U, HU, HUTF, W and B hangers normally have single-piece stirrups; ... ; specify HDG. CODES: Modified hangers, due to their numerous variations, are ... , use the smallest reduction factor to give the lowest design loads. TO ORDER ... : Use the abbreviations below to order specials. The example shows a ... most available options; most special hangers have only a few of these features. ... . N54A fasteners are supplied with hangers. B, W and GLT hangers for sloped seat ...

Bevel-cut the joist for skewed Type A hangers (see illustration). Butt-cut the joist ... for Type B hangers. Hangers with a skew greater than 15 may have ... . SLOPED AND/OR SKEWED SEAT Non-skewed hangers can carry the design load when the seat ... joist slope. Designer must check that wood bearing is not limiting. W/WNP/WP/HW ... series may be skewed to a maximum of 84 and/or sloped to a ... options are available for uplift hangerscheck the Hanger Options Matrix) Hangers can ... be sloped to 45 and/or skewed 45 at 100% of the ... uplift load. Skew option is only on hangers with W 3 or less. For skews greater ... center of joist will be flush with the top of the header (see illustration). ... TF sloped, and offset options. SLOPED TOP FLANGE A top flange may be ordered ...

/LSSU connectors. U/HU may be skewed to a maximum of 67 and sloped to a ... maximum of 45 . Hangers skewed 51-67 require a square cut. ... of the table load. For skewed only HUC hangers, the flange on the acute side can be ... for skew limitations. For sloped only hangers, flanges can be concealed at 100% of ... the table load. For sloped and skewed hangers, the flange on the acute side can be ... Sloped Down, Skewed Right Installation Top View U Hanger Skewed Right 51 (Square ... Cut) Maximum Skew Degree for Skewed HUC Hangers 1. Widths greater than 3 " maximum skew ... is 45 . Top View HUTF Hanger Skewed Right See ... AND/OR SKEWED SEAT HUTF can be skewed to a maximum of 45 or sloped to a maximum ... and sloped down only, provided W 2 ". Hangers with a skew greater than 15 may have ...

Down Installation with Full Backing Top View B Hanger Skewed Right Typical LBV ... Sloped Down with Top Flange Open B Hanger Sloped Down and ... Skewed Left with Sloped Top Flange Installation When ordering, ... or High Side Flush 1. Use this table to calculate allowable loads for modified ... hangers. 2. Examples: LBV with top flange sloped down right 30 , reduce ... download to [(90-30)/90] x table load. B skewed ... ), multiply .95 x table load. 3. For hangers with heights less than Min. Height ... factors shown in this table apply to the Nailer Table on page 100. 6. For ... Factors Nailers 5 SADDLE HANGER Saddle hangers are made to order; add D to model (e.g ... thickness apply (see page 77). Saddle hangers achieve catalog load listed. Saddle ... hangers on stud walls do not achieve catalog ...

Bevel-cut the carried beam for skewed hangers. HANGER HEIGHT For hangers exceeding ... HGLTV and GLS/HGLS series may be skewed to a maximum of 50 or sloped to a maximum ... allowed for the HGLT/HGLS/HGLTV. SLOPED TOP FLANGE A top flange may be sloped down ... left or down right to 30 with or without a sloped and/or ... interpolation (see page 190). OFFSET TOP FLANGE The top flange may be offset ... HGLT/HGLS/HGLTV. For skewed and offset top flange hangers, the maximum allowable ... /HGLT/GLS/HGLS/GLTV/HG LTV Typical GLT Top Flange Offset Left (HGLT similar) ... Typical HGLT Top Flange Sloped Down Left with Low Side ... Options General Notes. SKEWED SEAT GH hangers may be skewed to a maximum of 45 bevel ... load. Specify GHD for saddle-style hangers. GHD may not be skewed. Typical GH ...