4 Wood Construction Connectors ALPHABETICAL ...
6 Wood Construction Connectors TABLE OF ... 77-81 ENGINEERED WOOD STRUCTURAL COMPOSITE LUMBER CONNECTORS ... .................... 132-136 Multi-Ply Wood Trusses .................. 139, 140 Top ... , fertilizers, preservative-treated wood, dissimilar metals, and other corrosive ... is apparent or suspected, then the wood, fasteners and connectors should be ... last several years, pressure treated wood formulations have changed significantly ... -D (Carbonate), CBA-A and CA-B treated woods are approximately 2 times more ... while SBX-DOT (Sodium Borate) treated woods were shown to be less corrosive than ... from some newer pressure-treated wood is a new issue with little historical ...

7 Wood Construction Connectors CORROSION ... including water-proofing of the wood used in your outdoor project is also a ... good practice. For wood with actual retention levels greater ... Verify actual retention level with the wood treater. When using Stainless Steel ... per ASTM A153. Testing indicates wood installed dry reduces potential ... corrosion. If dry wood is used, see our website for additional ... , or other coatings from the treated wood supplier for the type of wood used. ... ACZA SBX/DOT Zinc Borate Untreated Wood ACQ-C, ACQ-D (Carbonate), CA-B CBA-A ... or material. If a pressure treated wood product is not identified on the chart ... Steel connectors and fasteners. 1. Woods with actual retention levels greater ... Contact level). 2. Borate treated woods are not appropriate for outdoor use. 3 ...

11 Wood Construction Connectors NEW PRODUCTS ... to solve the challenges of mounting wood or steel ledgers to insulated concrete ... coil strap, our new FSC connects upper floors to lower floors from the inside of the ...
14 Wood Construction Connectors IMPORTANT ... , since the specific gravity of these wood species fall within the specific ... specific gravity for the different wood species as listed by NDS. For your ... replaced. j. A fastener that splits the wood will not take the design load. Evaluate ... will perform as required. Dry wood may split more easily and should be ... evaluated as required. If wood tends to split, consider pre-boring ... nail diameter (2001 NDS 11.1.5.3). k. Wood shrinks and expands as it loses and ... perpendicular to its grain. Take wood shrinkage into account when designing ... ; contact the factory. The effects of wood shrinkage are increased in multiple ... consideration given to possible future wood shrinkage. Care should be taken to not ...

15 Wood Construction Connectors IMPORTANT ... of load adjustments for fasteners into wood as specified by the code are as ... loading. e. Unless otherwise noted, wood shear is not considered in the loads ... given; reduce allowable loads when wood shear is limiting. Glulam 145 psi, LVL ... cross-grain tension or bending of the wood during loading if not sufficiently ... consideration given to possible future wood shrinkage. Care should be taken to not ... and Resistance Factor Design (LRFD) for wood has been published in AF PA/ASCE 16. ... hostile environments, with excessive wood shrinkage, or with abnormal loading or ...

19 Auto-Feed Screw Driving Systems QUIK DRIVE FASTENERS AND ATTACHMENTS Panel Grade Minimum Nominal Width of Framing Member Panel Thickness 6 4 2 3 2 3 6 6 Screw Spacing at Other Panel Edges 2 Code Ref. 4 3 Case 1 (No unblocked edges or continuous joints parallel to load) All other configurations (Cases 2, 3, 4, 5 and 6) BLOCKED DIAPHRAGMS 2 Screw spacing at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 and 4), and at all panel edges (Cases 5 and 6) UNBLOCKED DIAPHRAGMS Screws spaced 6 inches, maximum, at supported edges 2 Structural I Sheathing, single ...

21 Concrete Connectors RFB Retrofit Bolts RFBs are clean, oil free, pre-cut threaded rod, supplied with nut and washer. Offers a complete engineered anchoring system when used with the Epoxy-Tie or SET Epoxy. Inspection is easy; the head is stamped with rod length and No Equal symbol for identification after installation. MATERIAL: A307 Grade C. FINISH: Zinc Plated, available in HDG. See page 29-32 for application information and request T-ANCHORSPEC for additional product use information. Model No. L Bolt Diameter RFB#4X5 RFB#4X4 RFB#5X5 5 4 RFB#4X6 6 RFB#4X7 7 RFB#4X10 10 5 RFB#5X8 8 8 RFB#5X10 ...

26 Concrete Connectors UFP Universal Foundation Plate Model No. Girder Dimensions Allowable Loads W L H 2x Plate H 3x Plate S Floor (100) Roof (125) GH46-6 4x6 3 6 4 6 2000 2000 7, 90, 121 170 GH46-8 4x6 3 6 4 8 2000 2000 GH48-6 4x8 3 6 6 6 2000 2000 GH48-8 4x8 3 6 6 8 2000 2000 GH66-6 6x6 5 8 4 6 4000 4000 GH66-8 6x6 5 8 4 8 4000 4000 GH68-6 6x8 5 8 6 6 4000 4000 GH68-8 6x8 5 8 6 3 3 5 5 3 3 5 5 8 4000 4000 Code Ref. 1. Loads may not be increased for short-term loading. 2. A mudsill on top of the GH is required to achieve the table loads. 3. Models listed are for a 2x plate, ...
. 4. FAP shall use a minimum SDS wood screw length of 2 plus the shim ... the mudsill by means other than the FAP wood screw. 6. See page 20 for SDS wood ... mudsill by means other than the FAP SDS wood screw. FJA/FSA Typical FJA Installation ...
psi. 2. For ACQ or CA pressure-treated wood order products Mechanically Galvanized ... psi. 2. For ACQ or CA pressure-treated wood, order products HDG. For additional ... of 2-inch (nominal thickness) wood sill plates, with specific gravity of ... slabs or footings. For species of wood with specific gravity of 0.42 to 0.49, ... shear walls by 0.81. For species of wood with specific gravity of 0.31 to 0.41, ... to address most pressure-treated wood applications. The following information ...
consideration given to possible future wood shrinkage. Care should be taken to not ... act as one unit without splitting the wood. See SSTB Anchor Bolts on page 33-34 ... . 2. Loads are based on static tests on wood posts, limited by the lowest of 0.125" ...

/HD Holdowns * Typical HD5A Tie between Floors Vertical HD15 Installation HD5A (HD2A ... used to transfer tension loads between floors, to tie purlins to masonry or concrete ... diameter spacing from the end of the wood member to the center of the first bolt ... See General Notes. Contact engineered wood manufacturers for connections that are ... ), and on stud bolt nuts against the wood. The Load Transfer Plate is an integral ... load for a specific job. Locate on wood member to maintain a minimum distance ... automatically maintained when end of wood member is flush with the bottom of the ... act as one unit without splitting the wood. For additional information, request T- ... consideration given to possible future wood shrinkage. Care should be taken to not ...
ABU88R may be installed with 8-SDS X3 wood screws for the same table load. 5. For ... 1" standoff height above concrete floors, code-required when supporting ...
consideration given to possible future wood shrinkage. Care should be taken to not ...
for installation on top of raised wood floor systems. All 2nd Floor ... use on the second floor of two-story wood light-frame construction. Simpson ... at the 2nd floor to compensate for wood shrinkage and settlement due to dead ...
64 Shearwall STRONG-WALL SHEARWALL RAISED FLOOR 2nd FLOOR The building designer shall verify that these details are consistent with the complete load path requirements of the structure. 1. For plywood shear panel, add P to model name (e.g. SW24x8P), and multiply the table loads by 0.88. 2. For two-pour applications, use SSTB34. See SSTB anchor bolts, pages 33-34, for allowable loads and installation. Alternate diameter anchorage may be required depending on load. 3. All thread rod not supplied with Raised Floor walls. Minimum ASTM A307 required. Engineer of record must specify if high strength ...
of the template if the design is for a wood 1st floor or 2nd floor application. 4 ...
hangers that incorporate Simpsons SDS wood screws. Designed and tested for ... screws supplied. For use on solid sawn wood members. CODES: See page 12 for Code ... 2.See page 91 for additional engineered wood products sizes. 3.When using structural ...
69 Solid Sawn Connectors LUS/HUS Double Shear Joist Hangers LOAD TABLE EXPLANATION This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. See Hanger tables on pages 70 to 76. See Hanger Options on pages 188 for hanger modifications, which may result in reduced loads. All hangers in this series have double shear nailing. This patented innovation distributes the load through two points on each joist nail for greater strength. It also allows the use of fewer nails, faster installation, and the ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ...
71 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (DF SP) CODES: See page 12 for Code Listing Key Chart. Available with additional corrosion protection. Check with factory. Ga Doug Fir Larch/Southern Pine Allowable Loads Code Ref. W H B Joist Uplift Roof (125) 10d (133) (160) 10d 16d 10d 16d 10d 16d 2x12 LU210 20 1 7 1 10-10d 10-16d 6-10dx1 11% U210 16 1 7 2 10-10d 10-16d 6-10dx1 720 865 1110 1330 1275 1530 1390 1660 + 53% HU212 14 1 9 2 10-16d 6-10dx1 720 865 1340 1540 1675 + 347% HUS210 16 1 9 3 30-16d 10-16d 2845 3000 3775 3920 4020 + 378% DBL 2x12 LUS210-2 ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ...
73 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size Model No. Ga Dimensions Fasteners Spruce-Pine-Fir Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES 2x4 LU24 20 1 3 1 4-10d 4-16d 2-10dx1 LUS24 18 1 3 1 4-10d 2-10d U24 16 1 3 1 4-10d 4-16d 2-10dx1 210 250 385 460 440 530 480 575 HU26 14 1 3 2 4-16d 2-10dx1 210 250 465 535 580 DBL 2x4 LUS24-2 18 3 3 2 4-16d 2-16d U24-2 16 3 3 2 4-10d 4-16d 2-10d 255 305 385 460 440 530 480 575 HU24-2 14 ...

74 Solid Sawn Connectors FACE MOUNT HANGERS SOLID SAWN LUMBER (SPF) Joist Size Model No. Ga Dimensions Fasteners Spruce-Pine-Fir Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d SAWN LUMBER SIZES DBL 2x12 LUS210-2 18 3 9 2 8-16d 6-16d U210-2 16 3 8 2 14-10d 14-16d 6-10d 770 920 1345 1610 1545 1850 1680 2010 LUS214-2 18 3 10 2 10-16d 6-16d HUS210-2 14 3 9 2 8-16d 8-16d 1755 2105 1650 1900 2065 HUS212-2 14 3 10 2 10-16d 10-16d 2195 2630 2065 2375 2580 HU212-2 (Min) 14 3 10 2 16-16d 6-10d ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 6. NAILS: 16d 0 ...
76 Solid Sawn Connectors FACE MOUNT HANGERS ROUGH LUMBER (DF SP) FACE MOUNT HANGERS ROUGH LUMBER (SPF) Joist Size Model No. Ga Dimensions Fasteners Doug Fir Larch/Southern Pine Allowable Loads W H B Header Joist Uplift Floor (100) Snow (115) Roof (125) 10d 16d (133) (160) 10d 16d 10d 16d 10d 16d ROUGH LUMBER SIZES 2x4(R) LU24R-18 18 2 3 1 4-16d 2-10dx1 U24R 16 2 3 2 4-10d 4-16d 2-10dx1 240 265 445 530 510 610 555 665 2x6(R) LU26R-18 18 2 4 1 6-16d 4-10dx1 U26R 16 2 5 2 8-10d 8-16d 4-10dx1 480 575 890 1065 1020 1225 1110 1330 2x8(R) LU28R-18 18 2 6 1 8-16d 6-10dx1 ...

79 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) 1.N54A fasteners are supplied with hangers. 2.16d sinkers may be used where 10d commons are called out with no load reduction. 3. Uplift loads have been increased 33% and 60% for earthquake or wind loading with no further increase allowed. Divide by 1.33 and 1.60 for normal loading such as in cantilever construction. Joist or Purlin Size Model No. Ga Dimensions Fasteners DF/SP Allowable Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift (160) Floor (100) Snow (115) Roof (125) SAWN LUMBER SIZES 2x4 HU24TF ...

80 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) Joist or Purlin Size Model No. Ga Dimensions Fasteners DF/SP Allowable Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift (160) Floor (100) Snow (115) Roof (125) SAWN LUMBER SIZES TPL 2x16 HU216-3TF 12 4 15 2 2 20-16d 8-16d 1470 1765 5050 5050 5050 Lowest 3x4 HU34TF 12 2 3 2 2 8-16d 2-10dx1 245 295 2600 2600 2600 * 3x6 W36 12 2 5 2 2 2-10d 2-10dx1 2200 2200 2200 * WM36 12 2 5 3 3 2-16d DPLX 2-10dx1 4100 4130 4150 * HU36TF 12 2 5 2 2 10-16d 4-10dx1 490 590 3725 3900 3900 * 3x8 W38 12 ...

81 Solid Sawn Connectors TOP FLANGE HANGERS SOLID SAWN LUMBER (DF/SP) See footnotes on page 79. CODES: See page 12 for Code Listing Key Chart. Joist or Purlin Size Model No. Ga Dimensions Fasteners DF/SP Allowable Loads Installed Cost Index (ICI) W H B TF Header Joist Uplift (133) Uplift (160) Floor (100) Snow (115) Roof (125) SAWN LUMBER SIZES 4x14 HUS414TF 14 3 13 2 2 12-16d 8-16d 2160 2160 4765 5100 5100 Lowest B414 12 3 13 + 8% WNP414 12 3 13 2 2 2-10d 2-10d 3255 3255 3255 + 13% HU414TF 12 3 13 2 2 18-16d 8-10d 1250 1500 4830 5050 5050 + 89% HW414 11 3 13 2 2 4-10d 2-10d ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 4.NAILS: 16d 0. ...
84 Solid Sawn Connectors HRC Hip Ridge Connectors PF Post Frame Hangers PFD26 (PFD24, PFDS26,PFD26L similar) U.S. Patent 5,104,252 PFD and PFA post frame hangers have double shear nailing to speed installation. Diamond holes allow easy hanger alignment and attachment. MATERIAL: 20 gauge FINISH: Galvanized. Some products available in Z-MAX; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified fasteners. See General Notes. Diamond holes on PFD allow optional top flange nailing. Double shear nailing distributes the load through two points on each nail for greater strength. ...

85 Solid Sawn Connectors THA/THAC Adjustable Truss Hangers This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. The THA series extra long straps allow full code nailing and can be field-formed to give top flange hanger convenience. Designed for 4x2 floor trusses and 4x beams, the THAR/L422 has a standard skew of 45 degrees. Straps can be formed to give top flange hanger convenience. PAN nailing helps eliminate splitting of 4x2 truss bottom chords. MATERIAL: See table. FINISH: Galvanized. ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 4. NAILS: 16d 0 ...
88 Engineered Wood Structural Composite Lumber Connectors ... GENERAL CONNECTOR INSTALLATION WOOD NAILERS Nailer Too Wide The loading may ... may cause uneven surfaces and squeaky floors. Hanger Not Plumb A hanger kicked-out ... can cause uneven surfaces and squeaky floors. WOOD I-JOISTS SLOPED JOISTS For sloped ... unit. FASTENERS Use the correct nails. Wood may split if the nails are too large. ... of closelyspaced nails goes along the wood grain. For I-joist to I-joist ...
91 Engineered Wood Structural Composite Lumber Connectors ... the table value. Install HUCQs with SDS wood screws which are supplied with the ...
92 Engineered Wood Structural Composite Lumber Connectors ...
93 Engineered Wood Structural Composite Lumber Connectors ...
94 Engineered Wood Structural Composite Lumber Connectors ...
95 Engineered Wood Structural Composite Lumber Connectors ...
96 Engineered Wood Structural Composite Lumber Connectors ...
97 Engineered Wood Structural Composite Lumber Connectors ... ripped 2x framing to the top of another wood joist. MATERIAL: 20 gauge FINISH: ...
98 Engineered Wood Structural Composite Lumber Connectors ... HANGERS ITT/MIT/HIT/ITTM Engineered Wood Products Hangers A dedicated range of ... feature is specifically designed for wood web I-joists when used with the MIT or ... from a better angle. ITTM masonry-to-wood connectors can be directly embedded ...
of these features. 114 Engineered Wood Structural Composite Lumber Connectors ...
Cut Joist (HSUR similar) 116 Engineered Wood Structural Composite Lumber Connectors ...
117 Engineered Wood Structural Composite Lumber Connectors ...
119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS Glulam Beam Double Shear Joist Hangers Carried Member Width Model No. Ga Dimensions Fasteners Allowable Loads Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow (115) Roof Code Ref. (125) 3 GLULAM 3 GLULAM HU212-2 (Min) 14 3 10 2 2 16-16d 6-10d 905 1085 2145 2465 2680 1855 2135 2320 HU212-2 (Max) HU210-2 (Min) HU210-2 (Max) 3 10 2 22-16d 10-10d 1505 1810 2950 3390 3685 2550 2935 3190 HU3.25/10.5 3 10 2 22-16d 10-10d 1505 1810 ...

122 Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT Beam Glulam Saddle Hangers See table on page 123. See Hanger Options on page 188 for hanger modifications, which may result in reduced loads. GLT and HGLT accommodate typical structural requirements for timber and glulam beams. GLT top flange depth allows installation on minimum 4x ledger (3 net). Not acceptable for nailer applications. Funnel flanges allow easy installation of beams. GLS and HGLS are heavy glulam saddle hangers. Tested and code-listed seismic tie provisions are added to the GLS or HGLS order GLST or HGLST. The seismic ...
for glulam sizes are based on 560 psi wood bearing. 6. Maximum allowable ...
125 Plated Truss Connectors THA/THAC Adjustable Truss Hangers This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. Minimum Carried Member Model No. Ga Dimensions Fasteners 1 Doug-Fir-Larch/Southern Pine Allowable Loads Spruce-Pine-Fir Allowable Loads W H C Carrying Member Carried Member Uplift 2 (133 160) Floor (100) Snow (115) Roof (125) Uplift 2 (133 160) Floor (100) Snow (115) Roof (125) Top Face Straight Slant MINIMUM NAILING TOP FLANGE 2x4 THA29 18 1 9 5 4-10d 4-10d 4-10d ...
ply hangers and on SPF/HF header wood species, see Technical Bulletin T- ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 5. Loads shown ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 8. Loads shown ...
loads that consider ANSI/TPI 1 wood member design criteria. 4.Strong-Drive ... . Installation using Simpsons SDS wood screws will provide an improved ...
loads for W and WP hangers used on wood nailers. Nailers are wood members ... joist bearing capacity for the specific wood species, up to the maximum test value ... joist bearing capacity for the specific wood species, up to the maximum test value ...
Chart. Typical THAL422 installed on 4x2 wood truss. THAL422 Top Face Straight ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 10d 0 ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 6. NAILS: 10d 0 ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 6. NAILS: 10d 0 ... loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ...
loads that consider ANSI/TPI 1-2002 wood member design criteria. 7. NAILS: 16d 0 ...
MSCPT2-2 MSCPT2 MSCPT2 Top View (MSCPT2-2 similar) MSCPT2N Top View (MSCPT2-2N similar) Model No. Dimensions Fasteners Doug-Fir-Larch/So. Pine Allowable Loads 1, 2 W1 W2 TF Header Joists Uplift Code Ref. (133/160) Floor/Snow/Roof/Wind (100/115/125/133) Hip Jack Total Hip Jack Total MSCPT2 1 5 2 26-16d 18-10dx1 750 370 1870 3145 1570 7860 170 MSCPT2N 1 5 2 26-16d 14-10dx1 750 1500 3930 7860 MSCPT2-2 3 5 2 30-16d 20-10d 750 370 1870 3470 1735 8675 MSCPT2-2N 3 5 2 30-16d 14-10d 750 1500 4335 8675 Model No. Dimensions Fasteners Spruce-Pine-Fir Allowable Loads ...

NEW! The THGQ and THGQH hangers for multi-ply girder trusses use SDS screws to provide high load capacities and easier installation compared to bolts. Both models offer minimum and optional maximum fastener quantities to accommodate varying design needs. Allowable loads for various girder web member sizes provide additional installation options. MATERIAL: THGQ 7 gauge, THGQH 3 gauge FINISH: Galvanized INSTALLATION: Use all specified fasteners. See General Notes. Can be installed filling round holes only, or filling round and triangle holes for maximum values. SDS screws supplied for all ...

SIMPSON Strong-Tie Typical THGB2 Installation Model No. Width (W) Fasteners Length of Fastener in Carrying Member Doug-Fir/So. Pine Allowable Loads Spruce-Pine-Fir Allowable Loads Carried Member Carrying Member Uplift 1 (133/160) Floor (100) Snow (115) Roof (125) Wind (133) Uplift 1 (133/160) Floor (100) Snow (115) Roof (125) Wind (133) THGB2 3 10-10d 2- MB 4- MB 8010 6650 3 5655 6505 7070 7540 4800 5520 6000 6400 4 6235 7170 7795 8315 5775 6640 7220 7235 6 6235 7170 7795 8315 5775 6640 7220 7235 THGB2 3 8010 6650 3 6385 7340 7980 8510 5550 6380 6935 7200 4 6385 7340 7980 8510 5550 6380 ...
of the truss hanger fasteners. Use of Wood Blocking to Achieve the Full Design ... Mount Hanger at a Panel Point. Use of Wood Filler Blocking for Carried Member ... in joints formed by the intersection of wood members have no load resistance. The ... by the Truss Designer. 1 2 3 MULTI-PLY WOOD TRUSS APPLICATIONS 139 Plated Truss ...
2001 NDS. 3. Loads are based on 1 thick wood side members and apply to 3 and 4 ply ... 2x wood truss applications. (Side and main ... members of same wood species.) Contact Simpson for other ... 140 Plated Truss Connectors MULTI-PLY WOOD TRUSS APPLICATIONS TSB Truss Spacer ... 134 Typical TSB2-24 Installation on 2x Wood Truss 1. No load duration increase ...
and MSTCM models are designed for wood to masonry applications. The MSTC ...
SA/HSA Strap Connectors 1.Loads include a 33% or 60% load duration increase on the fasteners for earthquake or wind loading, but DO NOT include a 33% stress increase on the steel capacity. Refer to page 13 for further explanation. 2.10d commons may be substituted where 16d sinkers are specified at 100% of the table loads. 3.16d sinkers (0.148" dia. x 3 long) or 10d commons may be substituted where 16d commons are specified at 0.85 of the table loads. 4.Allowable bolt loads are based on parallel-tograin loading and these minimum member thicknesses: MST-2 HST2 and HST5-4"; HST3 and HST6-4 ...

fasteners. See General Notes. Wood shrinkage after strap installation ... across horizontal wood members may cause strap to buckle ... minimum nail penetration and minimum wood edge and end distances. The table ... only-Use every other round hole if the wood tends to split. Use round and triangle ... for comparable MST loads, providing wood does not tend to split. For lap slice ... a tension connection between two wood members. An equal number of right and ...
-Floor Span Connector, connects upper floors to lower floors from the inside of the ... .125" deflection from static tests on wood members, steel ultimate divided by 2, ...
FTA for full loads. Nail holes between floors allow preattachment to the joist ... to the code when nails penetrate wood less than 1 ". 3. NAILS: 10d 0.148" dia ...
a single ply 2x truss may cause the wood to split. H9 attaching truss to top ... -plate load? 4. What is the species of wood used for the rafter and the top plates ... on the lowest performing species of wood.) 5. Will the hurricane tie be nailed ...
cross-grain tension or bending of the wood during loading if not reinforced ... . Nail holes are spaced to prevent wood splitting for single and double top ...
171 Straps Ties A Angles and Z Clips L/LS/GA Reinforcing and Skewable Angles Model No. Ga Dimensions Fasteners 1 (Total) Allowable Download (125) 2 W H B TF Z2 20 2 1 1 1 4-10dx1 465 Z4 12 1 3 2 1 2-16d 465 Z6 12 1 5 2 1 2-16d 485 Z28 28 2 1 1 1 10dx1 1 Z38 28 2 2 1 1 10dx1 1 Z44 12 2 3 2 1 4-16d 865 Code Ref. 170 4, 37, 87, 121 4, 37, 121 170 1. Z28 and Z38 do not have nail holes. Fastener quantities are as required. 2. Allowable loads have been increased 25% for roof loading (Z clips), 33% and 60% for earthquake or wind loading (A angles); no further increase ...

174 Miscellaneous HSS/SS Stud Shoes RPS Strap Ties Model No. Stud Size Fasteners Allowable Loads 1 Compression DF/SP Tension Floor (100) Roof (125) SS1.5 SS2.5 12-10dx1 12-10dx1 500 500 500 500 SS3 12-10d 665 785 SS4.5 14-10d 665 785 HSS2-SDS1.5 12-SDS x1 1200 1200 1000 HSS2-2-SDS3 HSS2-3-SDS3 12-SDS x3 1200 1200 1000 12-SDS x3 1000 1000 970 HSS4-SDS3 12-SDS x3 2x 3x 2-2x 3-2x 2x 2-2x 3-2x 4x 1200 1200 1000 Code Ref. 6, 121 6 6, 121 1. Roof loads are 125% of floor loads unless limited by other criteria. Floor loads may be adjusted for other load durations according to the ...
splices and uneven terrain, replacing wood posts. The PGT1.5Z-R is for 1 pipe (1 ... holes. PGTIC2Z-R to Rails Use SDS x1 wood screws (not supplied). Install on ... attaches to rails with four SDS x1 HDG wood screws (not supplied). See page 20 for ... over unstable soil or water. Minimize wood splitting by flattening nail points or ...
,022,165 RTR The RTC series secures two wood members forming a 90 corner to a ... bendable flanges. RTA-connects two 2x wood members at a 90 angle. RTF-connects ... members for easier alignment. Seat wood member in bracket with a C-clamp before ...
Model No. W Fasteners Allowable F1 Loads (100) FC4 3 8-16d 800 FC6 5 10-16d 920 Code Ref. 3, 39, 88, 121 1. Loads may not be increased for short-term loading. 2. A 2 minimum lumber thickness is required to achieve the full load. 3. NAILS: 16d 0.162" dia. x 3 long. See page 16-17 for other nail sizes and information. FC Typical FC Load Installation For fast, accurate framing. Three-dimensional nailing pattern results in high-strength joint values. Ideal for fence construction. MATERIAL: 16 gauge. FINISH: Galvanized INSTALLATION: Use all specified fasteners. See General Notes. CODES: See page ...
2 to 3 times faster installation than wood bridging. Space bridging to avoid ...
181 Miscellaneous WB/WBC/TWB/CWB/RCWB Wall Bracing J/JP Floor Beam Levelers Simpson Wall Bracing products offer effective options to resist racking during construction. Additionally the RCWB, CWB and WB/WBC can be used to fulfill the same code bracing requirements as a 1x4 let-in brace, but are cost effective and faster to install. Not designed to replace structural panel shearwall load-carrying component. The WBC (coiled WB) multiple product dispenser pack weighs less than 40 pounds, making storage and transportation easy. WB106C 15 pieces per roll, WB126C 12 pieces per roll, WB143C 10 pieces ...

Typical OT/OHT Installation 184 Architectural Products Group ARCHITECTURAL PRODUCTS GROUP RUSTIC COLLECTION OS OHS OHS135 OHS195 Model No. Ga Dimensions Fasteners Allowable Loads 1,2 W L Qty Dia (133) Tension/Uplift (160) STRAP TIES OS 12 2 12 4 1305 1565 OHS 7 2 12 4 1680 2015 OHS135 7 6 13 4 4205 5045 OHS195 7 6 19 8 8405 10085 Code Ref. 170 1435 565 1535 565 2585 815 2585 815 Model No. Dimensions Allowable Loads 1,2,3 Minimum Bolt End Edge Distances Bolts Tension/Uplift F1 Ga d1 d2 H W L Qty Dia Code Ref. OL 12 2 12 12 5 OHL 7 2 12 12 5 OT 12 2 12 12 ...
with Simpson x3 SDS yellow zinc finish wood screws (supplied with product). ... Size Model No. W H B No. of SDS x3 Wood Screws Douglas Fir Spruce Pine Fir ...
194 Wood Construction Connectors CONTINUOUS LOAD ... Includes product information for wood-to-wood, light gauge steel, concrete, and ... corrosion and some pressure-treated woods. Do-It-Yourself Connectors Catalog ...