19 results for wood joists to steel beam connectors found in 0.121 seconds

Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie


 

6 Wood Construction Connectors TABLE OF CONTENTS CORROSION INFORMATION ... 18, 19 CONCRETE CONNECTORS Anchor Adhesives ... ......................... ......... 22 Beam Seats ... Bases .............. 46-55 SHEARWALL Steel Strong-Wall ... 62-67 SOLID SAWN CONNECTORS Adjustable Hangers ... Mount Hangers ........ 76 Sloped/Skewed Connectors ................ 82, 86 Top Flange ... 77-81 ENGINEERED WOOD STRUCTURAL COMPOSITE LUMBER CONNECTORS ... 118 Sloped/Skewed Connectors ............ 114, 117 Top Flange ... 97-113 GLULAM BEAM CONNECTORS Concealed Joist Tie ... ....................... 119, 120 Hinge Connectors............... ..................... 161 Top Flange ... 121-123 PLATED TRUSS CONNECTORS Adjustable Hangers ... .................... 132-136 Multi-Ply Wood Trusses .................. 139, 140 Top ...


 

14 Wood Construction Connectors IMPORTANT INFORMATION GENERAL NOTES a. ... Strong-Tie Co., Inc. reserves the right to change specifications, designs, and ... or liability for such changes. b. Steel used for each Simpson product is ... selected based on the products steel specifications, including strength, ... , and weldability. Contact factory for steel information on specific products. c. ... , bolts and nails may not be combined to achieve highest load value. 8d (0.131" ... be noted (for example 8dx1 ). Refer to page 16, 17, NDS (National Design ... conditions must be adjusted according to the code. In many cases, Simpson code ... , since the specific gravity of these wood species fall within the specific ... specific gravity for the different wood species as listed by NDS. For your ...


 

values or the ultimate load on a steel test jig divided by 2.5. 2. 16d sinkers ... the LTT20B, add a standard cut washer to the seat. No additional washer is ... with the body of the holdown to achieve table loads. See Girder ... Tiedown Connectors on page 153 167 for installation ... Light Tension Tie is designed for 2x joists or purlins and the LTT20B is for nail- ... spacing makes the LTT20B suitable for wood I-joists if 10dx1 nails are substituted ... 16ds. The LTTI31 is designed for wood chord open web truss attachments to ... the specified number and type of nails to attach the strap portion to the top or ... side of purlin or beam (minimum 4x width (2-2x4 or 4x4), ... except LTT19). Bolt the base to the wall or foundation with a suitable ... rated epoxies for anchor bolt options. To tie double 2x members together, the ...


 

41 Anchors PA/HPA Purlin Anchors Wood-to-concrete and -concrete block connectors that ... Purlin Anchor must hook around rebar. Wood splitting may occur when anchor is ... nailed to wood less than 3 wide. For widths less than ... is 5". Minimum concrete block left-to-right edge distance is 20". CONCRETE BLOCK ... joints allowed); C A horizontal bond beam with two #4 rebars, 40" long, a maximum ... Code Listing Key Chart. PA/HPA Purlin to Concrete Wall For I-Joist applications ... 8 and IBC 1620.2.1 state: ... Diaphragm to wall anchorage using embedded straps ... shall have the straps attached to or hooked around the reinforcing steel ... , or otherwise terminated to effectively transfer forces to the ... reinforcing steel. Available with additional corrosion ... information. PA HPA35 PA/HPA Purlin to Concrete Block Wall ...


 

Loads (133 160) 1 W1 W2 L1 L2 H1 H2 Beam Surface Post Surface Post Top Surface ... cap over the lally column and attach to the girder. CODES: See page 12 for Code ... a 3 ply LVL and a 3 "diameter steel column 1. Loads may not be increased ... of the bearing loads using Fc equal to 425 psi for SPF, 625 psi for DF and 700 ... capacity. 3. Loads are for a continuous beam. 4.Spliced conditions must be detailed ... by the Designer to transfer tension loads between spliced ... splice condition load is 6750 lbs per beam side and the lally cap must be evenly ... loaded. 5. To achieve lateral loads, LCC pipe must be ... welded to the column with an fillet weld around ... BCS allows for the connection of 2-2xs to a 4x post or 3-2xs to a 6x post. Double ... shear nailing between beam and post gives added strength! The BC ...


 

77 Solid Sawn Connectors TOP FLANGE HANGERS JB/LB/BA/B/HHB Joist, ... Beam and Purlin Hangers HUTF/HUSTF Heavy ... NAILER TABLE This table also applies to sloped-seat hangers. B SERIES WITH ... normal deflection limit. Model Series Top Allowable Loads Header Type Fasteners ... into the joist. OPTIONS: HUTF Rough beam sizes are available by special order. ... details. Typical BA Installation on Wood Nailer Typical BD Saddle Installation ... BA B (HHB Similar) Double Shear Nailing Top View HU410TF LB, BA, B and HHB are ... embossment provides added stiffness to the top flange. The newly improved B ... load capacities. See tables on pages 79 to 81. See Hanger Options on pages 188 and ... loads. MATERIAL: See tables, pages 79 to 81. FINISH: JB, LB and B Galvanized; ... table. LB, BA, B and HHB may be welded to steel headers with weld size to match ...


 

78 Solid Sawn Connectors TOP FLANGE HANGERS W/WPU/WNP/WM/WMU/HW/HWU ... Allowable Loads Header Type Width Depth Top Face Joist Uplift (133 160) LVL PSL ... LSL DF/SP SPF I-Joist Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 ... Titens 2- x1 Titens 2- x1 Titens 9 to 28 6-10dx1 3380 3 to 30 3-10dx1 2- ... 485 4700 4880 3650 4165 4165 23 to 28 3-16d 4-16d 6-10dx1 315 4700 4880 ... 10dx1 5100 4000 4500 5285 3665 HWU 9 to 18 4-16d 4-16d 6-10dx1 810 6335 5500 ... 765 6335 5500 5535 6335 5415 23 to 28 4-16d 4-16d 6-10dx1 635 6335 5500 ... 1005 6335 5500 5535 6335 5415 9 to 18 4-16d 4-16d 6-10dx1 810 6000 5500 ... 26, 83, 124 1, 84, 140, 121 26, 124 1 to 4 1 to 4 1 to 7 1 to 7 4- x1 Titens ... 9 to 28 2-16d DPLX 6-10dx1 4175 1 to 7 1 to 7 1 to 7 1 to 7 1 to 7 1 to ...


 

91 Engineered Wood Structural Composite Lumber Connectors ... Typical HUCQ Installed on End of a Beam Typical HU7 Installation See Hanger ... tables on pages 92 to 96. See Hanger Options on page 188 for ... tabs) MATERIAL: See tables, pages 92 to 96. FINISH: Galvanized. Some products ... available in stainless steel or Z-MAX; see Corrosion-Resistance, ... Do not use double shear hangers with I-joists. Nails must be driven at an angle ... the joist or truss into the header to achieve the table loads. Not designed ... into the joist, and reduce the load to 0.64 of the table value. Install HUCQs ... with SDS wood screws which are supplied with the ... allowed. 2. Download columns apply to either Douglas Fir-Larch/Southern Pine ... lumber columns, screws must be applied to the wide face of the column. HUC412 ...


 

98 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS ITT/MIT/HIT/ITTM ... Engineered Wood Products Hangers A dedicated range of ... Top Flange I-joist hangers meeting the ... unique needs of I-joists while offering superior performance and ... . This constrains the I-joist, helping to reduce squeaks resulting from joist ... movement. Reduced embossing on the ITTs top flange, and the hanger height sized ... for bend-tab application is 1 to 1 ". MIT/HIT Patented Positive Angle ... feature is specifically designed for wood web I-joists when used with the MIT or ... material is not removed, but is used to channel and confine the path of the ... nail to the optimum angle. PAN minimizes ... from a better angle. ITTM masonry-to-wood connectors can be directly embedded ...


 

100 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS LBV/BA/B/HB I-Joist ... 3725 2770 1. This table assumes joists with Fc = 750 psi. For other joists, ... . See main table for loads specific to actual widths. 3. Uplift loads have ... on DF/SP header species. 8. Applies to LVL headers made primarily from Douglas ... values found in the SPF column. 9. DF I-joists include flanges made from solid sawn ... . For flanges with thicknesses from 1 to 1 , use 0.85 of the I-joist header ... . For flanges with thicknesses from1 to 1 , use 0.75 of the I-joist header ... Hanger Installation BA Installed LVL to LVL Max Nailing BA installed 2X nailer ... on steel beam minimum nailing Model Series Fasteners ... Allowable Loads Header Type Top Face Joist Uplift (133) Uplift (160 ...


 

101 Engineered Wood Structural Composite Lumber Connectors ... TOP FLANGE HANGERS W/WP/WPU/WM/WMU/HW/HWI/ ... 2 " WP/WPI NAILER TABLE Model Nailer Top Flange Nailing Allowable Loads DF/SP ... Loads Header Type Width Depth Top Face Joist Uplift (133 160) DF/SP ... DF/SCL I-Joist 5 Code Ref. Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 ... greater than 2") 26, 124 (widths up to 3 ") 26 124 26, 83 1, 84 1 to 4 3 to 30 ... 2-10dx1 2150 2020 2200 1435 1 to 4 3 to 30 2-16d 2-10dx1 2335 1950 ... 2335 1765 1435 WM 1 to 4 3 to 30 2-16d DPLX 2-10dx1 4175 WMU 1 to ... 7 9 to 28 6-10dx1 545 3380 1 to 7 9 to 28 2-16d DPLX 4- x1 Titens 4- ... 2- x1 Titens 6-10dx1 625 4175 1 to 7 3 to 30 3-10dx1 2-10dx1 2865 3250 ...


 

118 Engineered Wood Structural Composite Lumber Connectors ... PAI/MPAI Purlin Anchors PAI PAI Purlin to Concrete Wall (MPAI similar) Model No. ... 2865 2865 1960 2355 2865 2865 Code Ref. Wood-to-concrete and -concrete block connectors that ... fastener holes. See General Notes. Wood splitting may occur when anchor is ... nailed to wood less than 3 wide. To reduce splitting for widths less than 3 ... on page 16-17.) PAI is designed for wood I-joists. Nail spacing is for 10dx1 ... nails 3" on center, to minimize the chance of wood splitting. ... is 5". Minimum concrete block left-to-right edge distance is 20". CONCRETE BLOCK ... and below the anchor; a horizontal bond beam with two 4 rebars, 40" long, a maximum ... .2.8 and IBC 1620.2.1 state: Diaphragm to wall anchorage using embedded straps ...


 

" WNP2.6 and WNP3.3 WPU Model Nailer Top Flange Nailing Allowable Loads DF/SP ... . MATERIAL: WNP/WPI/WPU 7 ga. top flange, 12 ga. stirrup; HW 3 ga. top ... flange, 11 ga. stirrup; HWU 3 ga. top flange, 10 ga, stirrup. FINISH: Simpson ... . INSTALLATION: Hangers may be welded to steel headers with for WPU/WNP/ WP/WPI ... welds located at each end of the top flange. Weld-on applications produce ... information. Uplift loads do not apply to this application. Hangers can support ... the individual members must be secured together to work as a single unit before ... Loads Header Type Width Depth Top Face Joist Uplift (133 160) LVL PSL ... DF/SP SPF I-Joist Masonry Code Ref. 1 to 7 3 to 30 3-10dx1 2-10dx1 2865 ... 3250 2500 2000 2030 1 to 7 3 to 30 3-10d 2-10dx1 2525 3250 3650 ...


 

122 Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT Beam ... requirements for timber and glulam beams. GLT top flange depth allows ... flanges allow easy installation of beams. GLS and HGLS are heavy glulam saddle ... listed seismic tie provisions are added to the GLS or HGLS order GLST or HGLST. ... . Bolt holes shall be a minimum of to a maximum of larger than the bolt ... are included. GLT may be attached to steel headers by x 2 fillet welds at each ... end of the header angle to obtain the tabulated loads. HGLT may be ... attached to steel headers by x 2 fillet welds at each ... end of the header angle to obtain the lesser of the tabulated ... 12,000 lbs. Uplift loads do not apply to this weld-on application. See page 10 ... bolts. Loads listed are per stirrup. TO ORDER: GLS/HGLS Specify H1, H2, and S ...


 

W WP MATERIAL: W, WM 12 gauge top flange and stirrup, WP 7 gauge top ... fasteners. Hangers may be welded to steel headers with for W, and for WP, by 1 ... fillet welds located at each end of the top flange. Weld-on applications produce ... load listed. Uplift loads do not apply to this application. Hangers can support ... the individual members must be secured together to work as a single unit before ... nail pattern which relocates the nails to the bottom of the joist. OPTIONS: See ... cantilever construction. Model Nailer Top Flange Nailing Allowable Loads DF/SP ... Loads Header Type Width 4 Depth Top Face Joist LVL PSL LSL DF/SP SPF ... Code Ref. I-Joist Masonry W 1 to 3 3 to 30 2-10dx1 2-10dx1 1635 1740 1600 ... 1415 1 to 3 3 to 30 2-10d 2-10dx1 2150 2020 2200 ...


 

washer required NEW! As an alternative to coil strap, our new FSC-Floor Span ... Connector, connects upper floors to lower floors from the inside of the ... the FSC. Use threaded rod between 4' to 5' long, grade A307 or better, with ... maybe installed off the sill plate up to 18". Drill to diameter hole through the ... attachment. Nails can be installed up to 30 degree angle with no reduction in ... -Bent Straps Bottom 133/160% 133/160% Beam DF/SP SPF/HF Code Ref. Face Fasteners ... Width (min) Model No. Depth (min) Beam Dimensions Allowable Tension Loads ... reduce the capacity of the connection. To calculate a reduced capacity use 129 lb ... over the studs/post. 3. The 3" wide beam may be double 2x members. 4. MSTC48B3 ... MSTC66B3 installed over sheathing up to thick achieve 0.85 of table loads. 5. ...


 

cross-grain tension or bending of the wood during loading if not reinforced ... LTP5 may be installed over sheathing up to thick with no reduction in load when ... . The larger LTP5 spans subfloor at the top of the blocking or rim joist. The ... Tie Plate transfers shear forces for top plate-to-rim joist or blocking ... connections. Nail holes are spaced to prevent wood splitting for single and ... double top plate applications. May be installed ... reversible design permits the A35 to secure a great variety of connections ... . Some products available in stainless steel or Z-MAX; see Corrosion-Resistance, ... Code Listing Key Chart. A35 LTP5 A34 Joists to Plate with A Leg Inside 2 A35 1 A34 ... Ceiling Joists to Beam 5 LTP4 Installed over Plywood Sheathing ...


 

Top Face Top Face S/JCT (min) 1- #10 2- #10 4- #10 ... 6- #14 1515 2-10d 4-SDS x3 6- #14 1935 Steel Header S/JCT (min) 4- #10 940 S/JCT8- ... Allowable Load 1,6 Code Ref. Fasteners Steel Header Joist Wood Header Joist Welded ... Hanger x 2 fillet weld to each side of top Straight Hanger ... headers are based on a single 16 gauge steel. 2. Allowable loads for wood headers are ... minimum DFL, specific gravity 0.50. 3. Steel header must be braced to prevent web ... buckling per Designer specification. 4. Steel joist shall be laterally braced per ... ) S/HJCT Weld-On Installation with an I-Beam. Install joists fasteners as shown ( ... ) S/HJCT Installation with a 4x10 wood header (others similar) S/JCT8-14 ... Installation with a steel header (others similar) S/JCT8-14 S/ ...


 

CONCEALED JOIST TIES 1.Center pin in beam. Short pin (2 for use with 3 GLB, 4x ... ways: with no routing of header/post or beam; a routed header/post, or a routed beam ... a hex head driver. Router end of beam for screw heads for flush installation ... . The joist/beam may be sloped to 45 with full table loads. To provide ... maximum beam width for use with short pins, center ... in beam. Request F-CJT flier for installation ... 10 8 12 6 3535 3990 3990 GLULAM BEAM CJT3 3 x7 5 4 6 1240 1240 1240 ... 3255 4005 1655 2460 3255 4005 Chamfered Steel Pin (Galvanized) Typical CJT ... that pins should be centered within beam) CJT5 (others similar) The OHU ... with Simpson x3 SDS yellow zinc finish wood screws (supplied with product). ... Size Model No. W H B No. of SDS x3 Wood Screws Douglas Fir Spruce Pine Fir ...


 Similar searches:
wood joists to steel beam ... (20)
wood to steel beam connectors (27)
wood columns to steel beam (21)
saddle joist hanger steel ... (4)
post to steel beam ... (12)
steel beam to wood column (21)
wood beam connectors (51)
wood to steel (671)
wood columns to wood beam ... (7)
wood i beam connector (18)
steel beam to steel column (85)
double i beam connectors (9)
truss beam connectors (18)
steel beam (482)
glulam beam connectors (16)
wood joist hangars (1)
stamped steel beam clamp (4)
light gauge steel ... (10)
horizontal i beam connector (7)
round post to square beam (2)
steel beam hangers (51)
how to install n connectors ... (4)
how to install n connector (14)
joist to partition (7)
faux steel beam (1)
steel to steel hangers (223)
post beam connector (28)
metal post to wood i beam (3)
wood steel connectors (97)
metal fence post to wood ... (2)
simpson wood connectors (196)
wood construction connectors (211)
post to beam connections (21)
beam to post connection (21)
concrete to wood anchors (68)
post to beam (76)
wood beam (161)
shearwall to beam connection (2)
concrete to wood straps (30)
cmu to framing connectors (5)


Home | Latest catalogs | Contact