standard specification quick delivery cost effective ac series flowmeter general ac is a series of direct indication type variable area flowmeters with resins made construction thanks to union assembled construction removal of tapered tube and internal parts is possible without removing flowmeter itself from process piping this results in easy maintenance and cleaning/replacement of parts ail non-metallic material construction version is available for pure/ultra pure water or corrosive chemical process lines ac meets the requirements for quick delivery with competitive price features ● quick delivery and cost effective ● various connection fittings available rc thread ts socket or flange connection ● union assembling construction simple and easy installation and disassembling ● size line-up from 15mm 1/2 to 50mm 2 this can cover almost all requirements ● non-metallic material construction available no metallic ions are produced suitable for pure ultra

ac series flowmeter small size versions 15mm 20mm and 25mm standard specification available size 15 mm 1/2 20 mm 3/4 and 25 mm 1 calibration condition water density 1.0 g/cm3 viscosity 1.0 mpa·s special calibration/graduation available on request gas measurement is also acceptable consult factory for details scale range min 0.1 to 1 l/min ac-1501-t■ ac-2001-t■ max 10 to 100 l/min ac-256k 46 ■ range ability standard 10:1 10:2 for some versions graduation double scaled [l/min and l/hm3/h model code accuracy max.op.press temp range ±3 f.s 0.5 mpa test press 0.75 mpa 0 to 50°c it is general data and the maximum temperature may change by terms of use and environment ac– size – description – 1 5 15mm 1/2 2 0 20mm 3/4 2 5 25mm 1 range 1 range code 2 4 material class 1 6 material class 2 t material class 3 p material class 4 material 3 process connection rc thread ts socket or flange jis 10k lnstallation pipe line direct

ac series flowmeter flow rate table scale range model ✽1 alarm availability size 2 1 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 25mm 1 20mm 3/4 25mm 1 20mm 3/4 25mm 1 20mm 3/4 25mm 1 25mm 1 25mm 1 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 15mm 1/2 20mm 3/4 20mm 3/4 25mm 1 20mm 3/4 25mm 1 ac-1503-4/6 2003-4/6 1505-4/6 2005-4/6 1510-4/6 2010-4/6 1520-4/6 2020-4/6 1530-4/6 2030-4/6 2530-4/6 2040-4/6 2540-4/6 2050-4/6 2550-4/6 2070-4/6 2570-4/6 254k-4/6 256k-4/6 1501-t 2001-t 1502-t 2002-t 1503-t 2003-t 1505-t 2005-t 1510-t 2010-t 2020-p 2520-p 2030-p 2530-p 0.3 to 3 l/min 20 to 200 l/h 0.5 to 5 l/min 30 to 300 l/h 1 to 10 l/min 60 to 600 l/h 2 to 20 l/min 0.12 to 1.2 m3/h 5 to 30 l/min 0.3 to 1.8 m3/h 3 to 30 l/min 0.2 to 2 m3/h 4 to 40 l/min 0.25 to 2.5 m3/h 5 to 50 l/min 0.3 to 3m3/h 14 to 70 l/min 0.8 to 4 m3/h 10 to 100 l/min 0.6 to 6 m3/h ✽2

ac series flowmeter dimension 1 1 a 5 a a 5 5 detail drawing of “a” part 2 3 3 6 6 l1 l2 2 detail drawing of “a” part 4 4 4 l3 1 2 detail drawing of “a” part 3 6 d f ts socket version ● ● rc thread version model code ● flange version rc thread d 1 a 5 4 l2 8 2 detail drawing of “a” part 9 3 6 d ● 4 ts socket with alarm version tokyo keiso co ltd ac-1503-4/6 ac-1505-4/6 ac-1510-4/6 ac-1520-4/6 ac-1530-4/6 ac-2003-4/6 ac-2005-4/6 ac-2010-4/6 ac-2020-4/6 ac-2030-4/6 ac-2040-4/6 ac-2050-4/6 ac-2070-4/6 ac-2530-4/6 ac-2540-4/6 ac-2550-4/6 ac-2570-4/6 ac-254k-4/6 ac-256k-4/6 ac-1501-t ac-1502-t ac-1503-t ac-1505-t ac-1510-t ac-2001-t ac-2002-t ac-2003-t ac-2005-t ac-2010-t ac-2020-p ac-2030-p ac-2520-p ac-2530-p l1 ts socket l rc 1/2 ød l2 rc 3/4 f l3 15a jis10k 22.3 220 20 flange ended 220 300 20a jis10k 26.3 25 260 260 350 rc 1 29 32.3 25a jis10k rc 1/2 22.3 15a jis10k 220 20 rc 3/4 220 300 20a jis10k 26.3 25 260

ac series flowmeter medium size versions 40mm and 50mm standard specification measuring object liquids avoid the opaque liquids they might prevent visibility because of the direct reading of float through transparent tapered tube available size 40mm 1 1/2 and 50mm 2 scale range 1 standard pre-fixed range water density 1.0g/cm3 viscosity 1.0mpa·s size standard range 1 1 standard range 2 2 40mm 1 to 10 m3/h 0.6 to 6 m3/h 50mm 2 to 20 m3/h 1 to 10 m3/h 1 applicable for the flowmeter with the sus316 float having a float rod 2 applicable for the flowmeter with the resin made float pvc not having a float rod 2 possible scale range for custom made calibration/graduation flow rate is indicated by water flow ● ln case of sus316 float with float rod 50mm 1 point high or low reed switch spst adjustable by moving switch position 10 50 of full scale setting accuracy ±2 f.s reset span max.20 f.s capacity max voltage ac125v dc100v max current 0.5a ac,dc max wattage ac10va

ac series flowmeter dimension ts socket connection flange connection 1 1 2 2 3 l l 3 5 4 size l 40mm 510 50mm 530 4 ød øc ød size l c 40mm 445 50mm 460 above figure is for sus316 float with float rod version no float rod is provided for other float material versions d d 65 97 48.5 35 77 121 60.6 38 rc thread connection 1 2 material l 3 no size d l 40mm rc11/2 445 50mm rc2 460 c and d are the same as for ts socket version 6 4 tokyo keiso co ltd øc part name available material 1 body fittings pvc 2 tapered tube acryl 3 float sus316 pvc 4 o ring nbr epdm fpm others 5 float rod sus316 ød

ac series flowmeter ac-t non-metallic type without particles and metallic ions all parts consisting of fluorocarbon resin general ac-t is direct reading type variable area flowmeter whose wet parts consist of all fluorocarbon resin the flow rate is indicated directly by the float location on the measuring scale the simple and rugged construction offers you reliable operation and easy maintenance for various services the optional alarm contact serves for flow stoppage alarming in addition to flow monitoring features ● all wet components consisting fluorocarbon resin eliminate the effluent of metallic ions in process liquid ● eliminating float rod the ribbed taper tube prevents the generation of particles and assures stable movement of the float ● not only for pure water or ultra-pure water this anti-corrosion flowmeter is suitable also for other corrosive chemicals ● the union construction makes overhaul assembly and cleaning easier ● easy to mount on the

ac series flowmeter model code dimension ac-t description – connection size 15 15mm 1/2 20 20mm 3/4 1 2 20l/min 2 3 30l/min 3 4 40l/min 4 5 50l/min 9 others 1 2 6 5 7 connection type 3 l scale range 1 welding kgf type 2 rc thread 9 others 4 5 2 – 0 not provided – 1 provided 6 alarm contact 1 connection size 20mm 3/4 is available for all scale ranges connection size 15mm 1/2 is available only for all scale ranges 1 2 20l/min and scale range 2 3 30l/min ød standard material table unit mm part name material 1 socket pvdf 2 union socket pvdf 3 tapered tuberibbed pfa 4 float pvdf 5 float stopper pfa 6 o ring fpm fluoric rubber 7 scale plate acryl ac-t15- ac-t20- 15 220 rc1/2 20 220 rc3/4 tube outside diameter 15 20 20 25 d 19.2 24.2 nominal diameter l screw welding type no 16.5 18 kgf type kgf type sus316 weight moulded product mass for inquiry 400g please specify followings for your inquiry model code ac-t - if alarm contact is required