am-1000 series compact flowmeter ■ am-1520 series local indicator with electric transmitter am-1520 indicates flow rate by pointer and scale plate and outputs electric 4∼20 ma dc signal which is proportional to flow rate in addition to dust and splash-proof versions flame-proof versions are available ● dimension of indlcator/transmitter fig 3 dust and splash-proof am-152■ and exd ep-am-152■ optional units ● terminal and wiring ir series universal totalizer ir universal totalizer is an indicator and totalizer which is used in combination with am series flowmeters having 4∼20 ma dc or pulse output for flow rate indication totalization alarm 4∼20 ma dc and pulse re-output by one unit fig 4 weather proof am-152■ and exd ep-am-152■ ● specification of transmitter power supply voltage dust and splash-proof and flame proof 12∼30 v dc output 4∼20 ma dc max load dust and splash-proof and flame proof 600Ω 24 v dc

am-1000 series compact flowmeter ■ am-1740 series local indicator with alarm am-1740 indicates flow rate by pointer and outputs spdt contact at set point for flow alarm watertight flame proof and intrinsically safe versions are available ● specification of transmitter alarm point 1 point high alarm or 1 point low alarm or 2 points high and low switch micro switch spdt rating 125/250 v ac 5 a on request 30 v dc 0.1a setting accuracy ±1.5 f.s against flow calibration note the indication of flow rates except for the alarm setting value may be less accurate just after turning on the switch reset span weather proof and intrinsically safe less than 20 f.s against flow calibration flame proof ep-am-174■ less than 30 f.s cable entry g1/2 with female screw cable glands with a tiis flame-proof gasket are available ø7 mm to 12 mm standard ø11 mm to 12 mm on request npt 1/2 enclosure dust and splash-proof equiv to ip54 type am-174■ flame proof jisd2g4

am-1000 series compact flowmeter ■ additional functions ● liquid damper type am-1■ ■ ■-d a damper is to be provided for steam and gas applications to prevent vibration of float a damper pot is provided at the bottom of tube part in which damper liquid silicon or diflon oil is contained the friction between damper liquid and damper makes the float movement smooth for stable indication and durability of moving part damper is also recommended for liquid application with heavy pulsation available types are am-1■ ■3 bottom side-top side am-1■ ■6 leftright and am-1■ ■7 right-left refer to fig 11 fig 11 ● cooling fin type am-1■ ■ ■-f a cooling fin is to be provided between tube part and indicator housing to release fluid heat in case fluid temperature is more than 150oc cooling fin is available for models am-1■ ■2 bottom-top side am1■ ■3 bottom side-top side am-1■

am-1000 series compact flowmeter ■ dimensions material press drop flow rate table [metallic material ● type am-1■ ■1 flow direction:bottom-top for liquids type am-1■ ■1-lb bottom-top long body design ■ table 1 meter size qwater m3/h pressure loss kpa 15 20 25 40 50 65 80 100 125 150 0.1 to 0.75 0.7 1.5 1.5 4.06 3.8 7.15 7.15 15.1 15.1 27.5 26.5 40.5 39.5 71.9 67.5 110 – 150 – 6.5 6.0 7.3 9.0 6.3 7.8 9.1 12.0 14.0 18.0 10k class am-1■■■-■ l 1 b mass mm mm approx kg 350 89 5 350 89 5 350 92 6 400 99 8 400 105 10 450 113 13 450 120 15 450 132 20 500 145 32 500 158 50 note the values for mass approx in these tables are all for models with local indication 20k class am-1■■■-m l b mass mm mm approx kg 350 89 5 400 89 6 400 92 7 400 99 9 450 105 12 500 113 18 500 120 20 500 132 28 – – – – – – figures in are those of 20k class ■ table 2

am-1000 series compact flowmeter ● type am-1■ ■2-du flow direction bottom-top side with damper for gases ■ table 7 meter size 15 20 25 40 50 65 80 100 pressure loss kpa 2.92 to 17.1 2.8 39.3 4.0 77.7 2.7 129.9 2.9 254.7 3.4 440.8 2.6 630.6 4.0 1233.8 5.5 qair m3/hnor sizemm mass approx kg h l a jis 10k 690 690 690 690 700 800 820 860✽1 250 250 250 250 250 350 350 350 100 100 100 100 100 150 150 150 8 8 10 12 15 22 25 43 ■ table 8 fig 18 no 1 2 3 4 5 6 7 8 9 description tapered tube float ass y body flange upper flange lead pipe indicator bolt&nut gasket class 1 sus304 sus304 sgp✽2 ss400 ss400 sus304 adc12 ss400 non-asbestos ptfe class 2 sus304 sus304 sus304 sus304 ss400 sus304 adc12 ss400 non-asbestos ptfe class 3 sus316 sus316 sus316 sus316 ss400 sus316 adc12 ss400 non-asbestos ptfe class 4 sus316l sus316l ✽1 h dimension will be extended sus316l by 30mm with pneumatic transmitter without fin sus316l ss400 sus316l ✽2 stpg 370 for

am-1000 series compact flowmeter ● type am-1■ ■3-d for gases and steam flow direction bottom side-top side with damper ■ table 13 meter size 15 20 25 40 50 65 80 100 125 150 q 10k class am-1■■■-■ 20k class am-1■■■-m pressure loss mass mass air a h l1 l2 water h l1 l2 a m3h m3/hnor kpa mm mm mm mm approx kg mm mm mm mm approx kg 0.1 to 0.69 0.69 3.1 to 21.3 21.3 10.0 220 190 100 830 220 210 100 800 11 13 1.6 1.6 53 53 12.2 220 190 100 850 220 220 100 810 11 13 4.19 3.6 129.4 124 17.7 220 210 100 880 220 240 100 830 14 17 7.73 5.9 238 206 11.0 220 220 100 930 220 280 100 860 18 22 15.1 12.4 466 431 15.8 220 310 100 1050 220 370 100 960 21 28 29.3 25.0 904 831 19.5 1080 350 300 150 1180 350 370 150 29 38 ✽1 40.8 34.3 1260 1160 18.0 1130 350 310 150 1220 350 380 180 35 46 ✽1 ✽1 1280 350 400 180 70.8 55.0 2186 1934 19.5 1160 350 320 150 53 70 – 110 – 3300 – 22.0 1220✽1 370 360 250

am-1000 series compact flowmeter ● type am-1■ ■2 flow direction bottom-top side for liquids ■ table 25 meter size 15 20 25 40 50 65 80 100 125 125 150 ■ table 26 pressure h l loss kpa mm mm not available not available 700 320 0.8 to 2.7 5.5 730 350 4.3 4.8 780 380 7.0 11.4 810 400 5.4 20.2 870 440 10.0 33.0 1000 500 10.0 54.0 1020 500 14.0 88.0 1140 550 14.0 88.0 1150 600 20.0 140.0 qwater m3/h b mass mm approx kg 120 130 130 150 150 200 200 220 220 17 22 24 28 34 52 65 ✽1 70 ✽2 95 ✽1 for material class 5,6 ✽2 for material class 7 no 1 description tapered tube 2 float ass y 3 4 5 6 7 8 9 10 upper body lower body float guide upper flange lead pipe indicator bolt&nut gasket class 5 class 7 class 6 rubber lined rubber lined f.c.r lined pvc✽ f.c.r.✽ f.c.r.✽ other metalic material on reauest rubber lined rubber lined f.c.r lined rubber lined rubber lined f.c.r lined pvdf pvc pvdf ss400 ss400 ss400 fep tubed sus 304 pvc

am-1000 series compact flowmeter [glass lined material ● type am-1■ ■1 flow direction bottom-top for liquids ■ table 32 ■ table 31 f.c.r float ma276 float mass conn l b approx meter size qwater pressure pressure q size mm mm kg m3/h loss kpa m3/h loss kpa 20 570 0.1 to 0.4 6.0 0.1 to 0.6 10.0 15 92 18 25 552 not available 20 20 768 1 8.0 10.0 25 710 92 26 0.8 1.0 40 806 25 20 781 2 6.0 8.0 25 688 92 25 1.3 1.6 40 840 25 875 1 6.0 8.0 40 803 99 35 1.7 2.5 50 867 40 40 750 2 6.0 8.0 99 33 3.2 4.5 50 903 50 790 8.0 6.0 50 105 40 6.5 8 80 943 not available 65 80 835 10.5 9.0 80 120 55 17 20 100 987 100 870 11.5 9.0 100 132 70 35 45 150 1024 not available 125 not available 150 fig 32 no 1 2 3 4 5 6 7 8 9 description tapered tube float ass y upper body lower body float receiver float guide bolt&nut gasket indicator class 10 glass lined f.c.r.✽ glass lined glass lined pvdf pvdf ss400 ptfe adc12 class 11 glass lined ma276 glass lined glass lined ma276

am-1000 series compact flowmeter ● type am-1■ ■3-d flow direction bottom side-top side with damper for gases ■ table 35 fig 34 ■ table 36 no 1 2 3 4 5 6 7 8 9 10 11 description tapered tube float ass y body float guide upper flange lead pipe indicator bolt&nut gasket damper blind flange class 10 class 11 glass lined glass lined f.c.r.✽ ma276 glass lined glass lined ma276 pvdf ss400 ss400 fep tubed sus 304 adc12 adc12 ss400 ss400 ptfe ptfe glass lined glass lined ss400/ptfe ss400/ptfe f.c.r float ma276 float meter conn h pressure pressure q size qwater size mm m3/h loss kpa m3/h loss kpa 15 not available 20 not available 20 1 10 to 26 25 1010 9.0 12 to 33 11.0 40 25 20 54 2 25 1050 42 7.0 9.5 40 25 90 1 40 1110 70 7.5 10 50 40 25 115 2 40 1120 90 6.5 9.0 50 40 300 50 1190 240 50 8.0 9.0 80 not available 65 50 650 510 80 1300 10.0 80 11.5 100 80 1460 1140 100 1560 12.0 100 14.0 150 not available 125 not available 150 l1 l2 a1 a2 mass approx mm mm mm

am-1000 series compact flowmeter c slurry application consult factory if contaminations sand dirt and other solid particles are expected in fluid as-1000 series slurry flowmeter is available then all these figures are to be put into the formula qw 196 0.03 13.3m3/h 5.1 2 gas application a selection of meter size maximum possible flow rate for each meter size is shown in dimension tables of am-1■ ■1-du am-1■ ■2-du am-1■ ■3-du am-1■ ■3-d am-1■ ■6-d and am-1■ ■7-d flowmeters if actual fluid condition is different from such figures a conversion calculation is to be performed by the following formula qa q where qa q γ t p example 0.01635 273+t 0.1013+p converted flow rate in air 0oc 1atm m3 /hnor flow rate of measuring gas m3/hnor density of measuring gas kg/m3nor pressure of measuring gas oc temperature of measuring gas mpa gas to be measured nitrogen n2 specific weight γ 1.251kg/m3nor operating

am-1000 series compact flowmeter 5 scale graduation customer can select any one of the following 16 standard scale graduations if meter size and connection flange meet the specification rangeability is 10:1 example if required scale range is 150~1500m3/hnor the graduation on the flowmeter will be 15~150×10m3/hnor ● standard scale graduation 5 special orders a low pressure drop version if standard pressure drop does not meet the requirement low pressure drop version is available on request consult factory for further details b low temperature application if the fluid temperature is very low i e liquified gas etc special arrangement to prevent frost is available consult factory for further details c high pressure application up to 196mpa possible with experience consult factory for further details ■ ordering form model fluid name common density viscosity pressure temperature measuring range connection size flange rating material class ■ hot water jacket fluid