CP-22-100B+PGT Purging type Level Gauge 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | CP-22-100B+PGT Purging type Level Gauge 2017 | 12 pages | 2017-04-08

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

CP-22-100B+PGT Purging type Level Gauge 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of CP-22-100B+PGT Purging type Level Gauge 2017

to maintain constant flow c series purge set flowmeter with constant flow valve ■ general c series constant flow valves keep flow rate of gases or liquids even when the supply or load pressure changes control valve with diaphragm automatically acts following the change of pressure they are normally delivered together with flowmeter as a purge set primaryinlet pressure variation control type and secondaryoutlet pressure variation control type are ready to meet all possible applications ■ lineup c-21 c-31 c-11 p1inlet variation p1inlet variation p1inlet variation c-12 c-22 c-32 p2outlet variation p2outlet variation p2outlet variation measuring fluid gases only gases and liquids gases and liquids max fluid press mpa 0.7 1 0.8 max fluid temp c 120 120 120 controllable dp range c-11 0.03~0.3 0.06~0.4 0.1~0.5 mpa c-12 0.05~0.3 control accuracy f.s ±3 ±5 ±5 process connection rc 1/8 rc 1/4 rc 3/8 approx mass kg 0.2 0.9 2.3 it is general data and the maximum

c series purge set ■ applications ● supply pressure variation ● level measurement pressure gauge/dp p transmitter main valve h gus supply branch valve purge set purge set ȡ air supply as shown above in case one large supply line branches into several liquid level in tanks is measured by the back-pressure at the edge lines and the supply pressure changes because of stoppage of of purging pipe the outlet pressure at the tank bottom changes some branches primary pressure variation type purge set will be depending on the liquid level and constant bubbling is required suitable in keeping the purging volume of fluid thus secondary pressure variation type purge set is used for this application a dp transmitter is often connected to pressure line instead of pressure gauge for remote transmission recommended model of purgeset recommended model of purgeset cp-◻1-◻◻◻ cp-◻2-◻◻◻ cp-22-100-b ● purging for orifice plate

c series purge set ■ c-1 type ● standard specification ● dimention of constant flow valve unit model identification c-11 c-12 rc1/8 rc1/8 fluid press max 0.7mpa fluid temp max 120oc 9 40 it is general data and the maximum temperature may change by terms of use and environment 40 72 72 0.03mpa c-11 13 max controllable dp 0.3mpa 35 41 0.05mpa c-12 13 min required dp 40 28 max 3l/min nor air 0oc 0mpa 40 available flow ranges gases in out 9 c-12 outlet pressure variation control type 28 c-11 inlet pressure variation control type control accuracy ±3 f.s rc1/8 rc1/8 in process connection rc1/8 out material construction material part name standard option body sus304 aluminum,sus316 diaphragm chloroprene rubber cr fluoro rubber spring sus304 sus316 seal nitrile rubber nbr fluoro rubber ● examples of combination with flowmeter inlet pressure variation control type possible flow ranges as purge set air min.10~100ml/min nor 0°c 0mpa max.0.3~3l/min nor

c series purge set ■ c-2 type ● standard specification model identification c-21 inlet pressure variation control type c-22 outlet pressure variation control type available flow ranges max 2l/min water density 1.0g/cm3 viscosity 1.0mpa·s max 50l/min nor air 0oc 0mpa liquids gases fluid press max 1mpa fluid temp max 120oc it is general data and the maximum temperature may change by terms of use and environment min required dp cp-21-100 ● dimention of constant flow valve unit 0.06mpa max controllable dp 0.4mpa rc1/4 control accuracy ±5 f.s standard process connection material construction standard scs14 chloroprene rubber cr fluoro rubber spring sus304 sus316 seal nitrile rubber nbr fluoro rubber 45 rc1/4 rc1/4 o 2×m5 o c 39 67 39 max.35 out rc1/4 67 c 56 c-21 type [without valve in out in rc1/4 56 22 22 18 body 70 in option diaphragm 45 rc1/4 out 40 rc1/4 material part name 93 rc1/4 out rc1/4 in 30 70 max.35 2×m5 70 c-22 type 30 70 [with valve

c series purge set possible flow ranges as purge set water min.7~70ml/min max.0.2~2l/min air min.0.1~1l/min nor 0°c 0mpa max.5~50l/min nor cp-21-400 possible flow ranges as purge set wate min.8~40ml/min max.0.2~2l/min air min.0.2~1l/min nor 0°c 0mpa max.6~60l/min nor cm-21-900 160 200 236 250 18 38 1 rc 4 rc out 4-m5 max 71 25 40 40 thickness max t 4 hole 2 -ϕ19 87 56 4 out in in 10.5 s 18 o 1 1 rc 56 4 max 61 rc 125 1 4 outlet pressure variation control type possible flow ranges as purge set air min.0.1~1l/min nor 0°c 0mpa max.5~50l/min nor cp-22-100 70 possible flow ranges as purge set air min.0.1~1l/min nor 0°c 0mpa max.5~50l/min nor cp-22-200 4-ϕ5.5 4-ϕ5.5 70 60 200 265 375 355 225 140 115 180 290 270 65 60 in in rc1/4 30 90 110 cp-22-400 40 90 110 possible flow ranges as purge set air min.0.1~1l/min nor 0°c 0mpa max.5~50l/min nor 70 rc1/4 30 12 40 65 rc1/4 out rc1/4 out 12 possible flow ranges as purge set air min.0.2~1l/min nor 0°c 0mpa

c series purge set ■ c-3 type ● standard specification model identification c-31 inlet pressure variation control type c-32 outlet pressure variation control type available flow ranges liquids max 5l/min water density 1.0g/cm3 viscosity 1.0mpa·s max 150l/min nor air 0°c 0mpa gases fluid press max 0.8mpa fluid temp max 120°c it is general data and the maximum temperature may change by terms of use and environment min required dp cp-31-500 ● dimention of constant flow valve unit c-31 0.1mpa rc1/8 max controllable dp 0.5mpa control accuracy ±5 f.s material part name rc3/8 rc3/8 standard option body scs14/sus304 scs14/sus316 diaphragm chloroprene rubber cr fluoro rubber spring sus304 sus316 seal nitrile rubber nbr fluoro rubber in out ϕ110 ● examples of combination with flowmeter inlet pressure variation control type 72 standard process connection rc3/8 material construction outlet pressure variation control type also used for outlet

c series purge set ■ c-4 type ● standard specification ● dimention of constant flow valve unit model identification c-41 inlet pressure variation control type c-42 outlet pressure variation control type available flow ranges max 10l/min water density 1.0g/cm3 viscosity 1.0mpa·s max 300l/min nor air 0°c 0mpa gases fluid press max 0.8mpa fluid temp max 120oc ϕ185 160 liquids it is general data and the maximum temperature may change by terms of use and environment min required dp out 0.1mpa max controllable dp 0.6mpa in rc1/2 control accuracy ±5 f.s rc1/2 standard process connection rc1/2 ϕ120 material construction part name material standard option c-41 body sus304 sus316 diaphragm chloroprene rubber cr fluoro rubber spring sus304 sus316 o-ring nitrile rubber nbr fluoro rubber ● examples of combination with flowmeter inlet pressure variation control type also used for outlet pressure variation in liquid applications cp-41-500 outlet

c series purge set ■ special versions panel mount type ● outline this is a combination of one purge set one filter regulator and inlet pressure gauge on one panel board the necessary components for air purging are combined in one panel board that offers easy installation at site stable purging flow is maintained even when the secondary load pressure varies ● model code ● block diagram of system model code cp − constant flow valve outlet c-12 12 p-100-00 p-200-00 p-400-00 single double 1 purge meter model constant flow valve 2 4 press gauge purge set quantity − 1 − 2 regulator and gauge purgemeter a 0 mounting u − 4 material of gas contact part − 6 filter regulator n gasket c inlet f ● standard specification c diaphragm f type secondary pressure variation control type refer to the specifications of each component s panel the maximum fluid temperature is 45°c models for higher fluid temperature are available as option

c series purge set ● model code model code cp − constant flow valve 22 □ − □ a □ − □ □ □ □ − □ □ − □ c-22 22 p-100-00 p-200-00 p-400-00 single double 1 purge meter model descriptions 2 4 purge set quantity − 1 − 2 regulator and gauge a 0 mounting u − 4 material of gas contact part − 6 n gasket c f c diaphragm f s panel 4 e − r process connection type − n 1 2 process connection size 3 4 special − z panel or wall mount 2 inch pipe sus304 sus316 nitrile rubber nbr chloroprene rubber cr fluoro rubber chloroprene rubber cr fluoro rubber spcc sus304 epoxy painting rc npt 1/8 1/4 3/8 1/2 special for epoxy painting specify s/e or 4/e ● dimension 65 95 70 95 70 42 rc1/4 rc1/4 out O C ▼ ▼ 20 50 75 rc1/4 out 95 4×φ9 42 out 290 270 230 250 60 l 4×φ6.6 40 68 wall or panel mount type cp-221-1ao 40 68 175 35

c series purge set ■ special versions ■ air purging level measurement type with pgt purging pipe cp-22-100-b ● outline cp-22-100-b unit consist of a filter regulator inlet/outlet pressure gauges and change-over valves used for changing of measuring mode or purging mode these components are assembled into one panel board for easy installation this unit together with pgt purging pipe serves for tank level measurement containing solids particles and sticky liquids ● block diagram of system constant flow valve purge meter purge press gauge ● standard specification filter regulator supply press gauge measure/blow swich mes blow type secondary pressure variation control type fluid air supply air 0.3~1 mpa primary press to be adjusted to 0.2 mpa secondary press 0~0.15 mpa this range shows the case when water level is 0 to 15000 mm air to supply pgt purging pipe from to transmitter pgt purging pipe indicator scale range indication accuracy ±5 f.s

c series purge set ● dimension u bolt installation on 2 inch pipe cp-22-100-bu wall or panel mount type cp-22-100-b 2 pipe ∅60.5 u bolts and nuts ss400 secondary 280 l n 280 300 regulator primary measure blow 220 240 4-∅9 max 48 max 48 330 160 160 260 280 panel cut 220 220 4-∅9 box type cp-22-100-bz dual type cp-22-100-2b secondary secondary 190 280 270 secondary regulator regulator l primary 190 handling remarks attached primary measure blow 6 1 20 5 n n primary 4 400 2 pipe ∅60.5 l l n 300 regulator blow 4–rc1/4 200 measure blow 190 measure 190 400 8–∅9 48 160 380 360 190 120 panel cut 50 50 60 190 190 380 tg-f746-10e 190 360 50 8–∅9 tokyo keiso co ltd

c series purge set ■ pgt purging pipe pgt purging pipe sus304 sus316 or pvc pipe size stainless steel 10 15 20 25mm stainless steel 16000mm connection of measuring length sliding flange fs plug plug ℓ2 max measuring length fixed flange fw 18 26mm ℓ2 pvc stainless steel material rc1/4 rc1/4 rc1/4 fixed flange sliding flange t max.4000mm t pvc process connection rc1/4 200 more than 4000mm is socket type 130 material 10 to 25mm jis10k ∅c flange location is ∅c n–∅h ∅d ℓ other flange stan ℓ l l adjustable 15 to 40 mm jis10k n–∅h ∅d dards are available 45 ℓ1 ℓ1 45 connection of purging gas rc 1/4 other screw standards are available ∅d ∅x ● option devices optional parts to measure level are available contact us if required fkc differental pressure transmitter size ∅x ∅d ∅x ℓ1 d ℓ2 10a 17.3 11.3 17.3 46 15a 21.7 15.7 21.7 46 20a 27.2 21.2