magmax® egm2300c compact electromagnetic flowmeter general magmax® egm2300c is high performance and compact electromagnetic flowmeter suitable for water and sewage egm2300c is a combination of egs2000 primary head with polypropylene and hard rubber liner and high performance converter egc300 an excitation system extendable up to twice the commercial frequency has been introduced to reduce fluid noise and improved self-diagnostic functions include vacancy detection and detection unit monitoring 2.5 to 1000mm sizes are available features ❏ polypropylene liner size 25 to 150mm achieved high-durability and high-heat resistance suitable for water sewage and hot water for process temperature up to 90°c ❏ hastelloy c electrodes as standard ❏ high accuracy of ±0.5 of reading ❏ high speed data processing for quick response suitable for batch process control and for pulsating flow ❏ the excitation system extendable up to twice the commercial frequency allows

magmax® compact electromagnetic flowmeter egm2300c ● ● wetted part material liner [standard pulse output open collector output size 25 to 150mm polypropylene rating less than 32v dc 20ma ≤10khz size 200 to 1000mm hard rubber less than 100ma ≤100hz [option pulse rate hard rubber size 25 to 150mm 2 to 36,000,000 pulse/h 0.00056hz to 10khz refer to the liner material and pulse width flange one of the following selectable electrode hastelloy® c22 [standard 1 automatic pulse width by which duty factor to be 50 at full scale [option stainless steel/ss316 2 duty factor 1:1 fixed earth ring [option stainless steel/ss316 ● painting siloxane coating ● color grey primary head housing/converter 3 free setting 0.05 to 2000m/s ● housing jade green converter cover open collector output terminal box cover ● cable entry rating less than 32v dc 100ma max 2 × g1/2 female thread contents of output 2 × 1/2 npt female thread one

magmax® compact electromagnetic flowmeter egm2300c standard functions accuracy ● ● ● customer’s free measuring unit setting function indication and pulse output volume or mass and time unit in 7 characters can be cre for velocity ≥ 0.33m/s ±0.5 of reading ated for velocity 0.33m/s ±0.2 of reading velocity error of ±0.001m/s automatic zero adjustment function zero adjustment is automatically conducted at zero 2.0 adjust mode subject to zero flow bi-directional flow measurement function error ± of reading ● a flow-direction distinction signal is outputted in state output and current ● double range measurement function possible range setting range ratio 1 20 to 1 1.25 setting range of low range 5 to 80 of high range range selection by automatic or control input signal ● excitation current frequency switching function 1.5 1.0 0.5 0.0 0.0 standard mode 0.5 1/6 of supply frequency standard 1.0 1.5 2.0 12 velocity

magmax® compact electromagnetic flowmeter egm2300c fluid temperature and pressure range fluid temperature liner nominal size mm temperature polypropylene 25 to 150 –5 to +90˚c hard rubber 25 to 1000 –5 to +80˚c maximum pressure liner polypropylene hard rubber maximum operating pressure must be within the flange rating nominal size mm pressure mpa 25 to 80 except 65mm 4.0 pressure 65 100 to 150 1.6 the value on this table indicates maximum pressure which can 25 to 1000 15 be manufactured consult tokyo keiso for details permissible vacuum load vacuum not acceptable nominal size mm liner polypropylene hard rubber – not applicable minimum pressure kpa abs fluid temp 40˚c 60˚c 80˚c 90˚c 25 to 150 25 40 40 25 to 300 25 40 40 – 350 to 1000 50 60 60 – flow range 4 possible setting range m3/h possible setting range m3/h max velocity 0 to 12 m/s nominal size mm min velocity 0 to 0.3 m/s max velocity 0 to 12 m/s 0 to 21.2 300 0 to

magmax® compact electromagnetic flowmeter egm2300c liner material and flange ◎ standard ○ option − not applicable flange rating liner nominal size mm 25 40 50 65 80 polypropylene ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ − − − − − − − − − − − − hard rubber ○ ○ ○ ○ ○ ○ ○ ○ ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ polypropylene ◎ ◎ − − − − − − − − − − − − − − − − − − hard rubber − − − − − − − − ○ ○ ○ ○ ○ ○ ○ ○ − − − − ansi polypropylene ◎ ◎ ◎ ◎ ◎ ◎ ◎ ◎ − −

magmax® compact electromagnetic flowmeter egm2300c dimensions nominal size 25 to 15 0mm 260 137 26 82 120 140 140 38 38 10 76 grounding terminal m5 h2 h h3 esc w l flow direction standard nominal size 200 to 1000mm 260 137 26 82 120 140 140 38 38 10 76 esc h h2 h3 grounding terminal m5 w l flow direction standard 6 tokyo keiso co ltd

magmax® compact electromagnetic flowmeter egm2300c nominal size mm dimensions mm l 1 h mass kg h2 h3 w 2 jis 10k ansi 150 jis 10k ansi 150 jis 10k ansi 150 25 150 150 301 293 169 239 90 12 13 40 150 150 316 310 176 246 105 13 14 50 200 200 335 334 188 258 120 13 14 65 200 200 349 351 192 262 140 15 16 80 200 200 357 360 194 264 150 17 18 100 250 250 387 397 212 282 175 20 23 125 250 250 421 423 226 296 210 24 27 150 300 300 452 452 242 312 240 27 31 200 350 350 507 514 272 342 291 39 48 250 400 400 563 566 293 363 331 53 68 300 500 500 610 629 318 388 381 63 100 350 500 700 655 677 340 410 428 83 134 400 600 800 716 734 366 436 483 103 170 450 600 800 771 778 391 461 533 122 190 500 600 800 825 837 417 487 585 133 228 600 600 800 940 949 472 542 694 169 311 700 700 – 1053 – 531 601 812 250 – 800 800 – 1167 – 587 657 922 333 – 900 900 – 1269 – 639 709 1026 430 – 1000 1000 – 1379 – 691 761 1132 512 –

magmax® compact electromagnetic flowmeter egm2300c electrical connection mounting position of lcd display l– l direction version a version b version c a– a b b– c c– d d– n l indication part of egm2300c can be changed according to the flow a the mounting position will be arranged according to the customer’s request when ordering the arrow indicates standard flow direction flow direction can be changed by data setting protection cover is provided for power supply terminals power supply terminal cover description terminal l l l • l– – ac power supply dc power supply n l– grounding terminal description d– c– b– – – status output or control input b current output 4 to 20ma dc hart internal power supply a– current output 4 to 20ma dc hart internal power supply current output 4 to 20ma dc hart external power supply ● terminal type ● connection capacity

magmax® compact electromagnetic flowmeter egm2300c model code ● nominal size 25 to 150mm model egm2300c primary head v n 1 4 4 spec code primary head code v n 1 4 fixed code 4 0 1 c 4 6 7 8 abcd nominal size 3 4 5 abmn 9 flange fixed code type liner electrode material construction of electrode primary head housing flange material protection class fixed code calibration earth ring fixed code special feature converter spec code converter code fixed code type power supply fixed code cable entry fixed code housing fixed code output type fixed code special feature v n 3 0 4 4 v n 3 0 1 0 0 0 0 0 2 0 0 0 0 0 0 description standard flange type always 4 25mm 40mm 50mm 65mm 80mm 100mm 125mm 150mm din pn16 din pn25 din pn40 ansi class 150 ansi class 300 jis 20k jis 10k for size 50mm or more 1 others always 0 0 1 c compact version egc300 converter hard rubber 5 polypropylene t stainless steel ss316 1 hastelloy® c22 3 fixed mounting 1 carbon steel carbon steel 1 carbon steel

magmax® compact electromagnetic flowmeter egm2300c ● nominal size 200 to 600mm model egm2300c primary head v n 1 5 4 spec code primary head code v n 1 5 fixed code 4 0 1 c 0 efghklmn nominal size 2 3 4 5 abmn 9 flange fixed code type liner electrode material construction of electrode primary head housing flange material protection class fixed code calibration earth ring fixed code special feature converter spec code v n 3 0 4 4 converter code fixed code type power supply fixed code cable entry fixed code housing fixed code output type fixed code special feature v n 3 0 1 0 0 0 0 0 2 0 0 0 0 0 0 description standard flange type always 4 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm din pn10 din pn16 din pn25 din pn40 ansi class 150 ansi class 300 jis 20k jis 10k others always 0 0 1 c compact version egc300 converter hard rubbe 0 stainless steel ss316 1 hastelloy® c22 3 fixed mounting 1 carbon steel carbon steel 1 carbon steel stainless steel ss316l 3 ip66/67 0 always

magmax® compact electromagnetic flowmeter egm2300c ● nominal size 700 to 1000mm model egm2300c primary head v n 1 6 4 spec code primary head code v n 1 6 fixed code 4 0 1 c 0 prst nominal size 2 a n 9 flange fixed code type liner electrode material construction of electrode primary head housing flange material protection class fixed code calibration earth ring fixed code special feature converter spec code converter code fixed code type power supply fixed code cable entry fixed code housing fixed code output type fixed code special feature v n 3 0 4 4 v n 3 0 1 0 0 0 0 0 2 0 0 0 0 0 0 description standard flange type always 4 700mm 800mm 900mm 1000mm din pn10 ansi class 150 jis 10k others always 0 0 1 c compact version egc300 converter hard rubbe 0 stainless steel ss316 1 hastelloy® c22 3 fixed mounting 1 carbon steel carbon steel 1 carbon steel stainless steel ss316l 3 ip66/67 0 always 00 0 0 standard calibration 0 none 0 stainless steel ss316 2 h others 2 9 always

magmax® compact electromagnetic flowmeter egm2300c standard accessories ● parameter sheet ● instruction manual 1 :1 option ● g1/2 watertight glands for cable entry 1 set [symbol wg ● number of wiring connection 3 [symbol 3g ● no converter data parameter setting [symbol ns we will supply with standard data setting in case you have no request please set the data of flow range pulse rate and flow direction etc that required operating ordering instructions specify the following when ordering 1 model and spec code example model egm2300c primary head spec code vn1447n01ct3110000002000000 converter spec code vn3044a0520012100000 2 flow range full scale unnecessary when option is ns 3 option specify if necessary specify the symbol with reference to the option 4 fluid name specification is subject to change without notice head office shiba toho building 1 – 7 – 24 shibakoen minato-ku tokyo 105 – 8558 tel +81-3 – 3431