magmax® compact electromagnetic flowmeter egm2300c fluid temperature and pressure range fluid temperature liner nominal size mm temperature polypropylene 25 to 150 –5 to +90˚c hard rubber 25 to 1000 –5 to +80˚c maximum pressure liner polypropylene hard rubber maximum operating pressure must be within the flange rating nominal size mm pressure mpa 25 to 80 except 65mm 4.0 pressure 65 100 to 150 1.6 the value on this table indicates maximum pressure which can 25 to 1000 15 be manufactured consult tokyo keiso for details permissible vacuum load vacuum not acceptable nominal size mm liner polypropylene hard rubber – not applicable minimum pressure kpa abs fluid temp 40˚c 60˚c 80˚c 90˚c 25 to 150 25 40 40 25 to 300 25 40 40 – 350 to 1000 50 60 60 – flow range 4 possible setting range m3/h possible setting range m3/h max velocity 0 to 12 m/s nominal size mm min velocity 0 to 0.3 m/s max velocity 0 to 12 m/s 0 to 21.2 300 0 to 76.4 0 to 3053 0 to 1.36 0 to 54.2 350 0 to 104 0 to 4156 50 0 to 2.13 0 to 84.8 400 0 to 136 0 to 5428 65 0 to 3.59 0 to 143 450 0 to 172 0 to 6870 80 0 to 5.43 0 to 217 500 0 to 213 0 to 8482 100 0 to 8.49 0 to 339 600 0 to 306 0 to 12214 125 0 to 13.3 0 to 530 700 0 to 416 0 to 16624 150 0 to 19.1 0 to 763 800 0 to 543 0 to 21714 200 0 to 34.0 0 to 1357 900 0 to 688 0 to 27481 250 0 to 53.1 0 to 2120 1000 0 to 849 0 to 33928 nominal size mm min velocity 0 to 0.3 m/s 25 0 to 0.531 40 tokyo keiso co ltd tg-em146e-2