magmax® egm4050c compact electromagnetic flowmeter outline the magmax® egm4050c is a compact electromagnetic flowmeter consisting of the flange type egs4000 primary head which is lined with pfa or ptfe from the proven magmax series and the egc050 converter mounted on it the enhanced self-diagnosis unit can detect empty flow and monitor the status of the primary head nominal sizes of 10mm to 1000mm are available the egm4050c is ideal for chemicals and many other applications features ❑ high-quality clear pfa reinforced with a punched plate ensures high resistance against corrosion erosion and permeation applicable size 25 to 150mm ❑ pfa ptfe and other lining materials are available ❑ high accuracy of ±0.5 of reading ❑ high-speed data processing enables quick response suitable for controlling batch processes and measuring pulsating flows ● ❑ the extendable excitation system can handle applications with materials of wetting parts lining ptfe

magmax® egm4050c compact electromagnetic flowmeter ● fluid specifications ● ● ● temperature pressure conductivity −40 to +140ºc up to the rated pressure of flanges ✽ allowable temperature and pressure depend on lining materials for details see “lining material and flange.” 10μs/cm or more for 10 to 150mm 5μs/cm or more for 200 to 1000mm the conductivity of water must be at least 20μs/cm for any size ✽ for fluids under 10ºc such as cooling water for air-conditioning it is recommended to specify the anticondensation specification as an option terminal a(a、a +/ a −) d(d、d −) ● indicator indication two-line display on the first screen first line flow rate second line flow rate in bar graph switchable to/from ̶ status output low-flow cutoff any value from 0.0 to 20.0 fs can be set separately for the is as follows on 1 and off 2 fs for the current

magmax® egm4050c compact electromagnetic flowmeter accuracy ✽3 ● indication and pulse output for velocity ≥ 0.5m/s ±0.5 of reading error ± of reading for velocity 0.5m/s velocity error ± 2.5mm/s 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 0.5 1 2 12 flow velocity m/s ● current output add ±0.01ma to the accuracy of indication or pulse output ✽3 basic conditions fluid water fluid temperature 10 to 30ºc conductivity 150μs/cm or more supply voltage rated voltage ± 2 ambient temperature 18 to 28ºc upstream/downstream straight run 10d/2d d diameter warm-up time about 10 minutes measuring time 100s fluid temperature and pressure range fluid temperature lining material pfa ptfe etfe nominal size(mm) 25 to 150 10 to 20 200 to 600 200 to 1000 fluid temperature ambient temperature −40 to +140℃ −40 to +65℃ −40 to +120℃ allowable maximum pressure and negative pressure lining material pfa ptfe

magmax® egm4050c compact electromagnetic flowmeter flow range flow range that can be set m3/h nominal size (mm) min flow velocity 0 to 0.3m/s max flow velocity 0 to 12m/s flow range that can be set m3/h nominal size (mm) min flow velocity 0 to 0.3m/s max flow velocity 0 to 12m/s 10 0 to 0.085 0 to 3.393 250 0 to 53.013 0 to 2120.520 15 0 to 0.191 0 to 7.634 300 0 to 76.341 0 to 3053.640 20 0 to 0.339 0 to 13.572 350 0 to 103.908 0 to 4156.320 25 0 to 0.530 0 to 21.205 400 0 to 135.717 0 to 5428.680 40 0 to 1.357 0 to 54.287 450 0 to 171.765 0 to 6870.600 50 0 to 2.121 0 to 84.823 500 0 to 212.058 0 to 8482.320 65 0 to 3.584 0 to 143.352 600 0 to 305.370 0 to 12214.800 80 0 to 5.429 0 to 217.152 700 0 to 415.620 0 to 16624.800 100 0 to 8.482 0 to 339.288 800 0 to 542.880 0 to 21715.200 125 0 to 13.254 0 to 530.148 900 0 to 687.060 0 to 27482.400 150 0 to 19.085 0 to 763.404 1000 0 to 848.220 0 to 33928.800 200 0 to 33.930 0 to 1357.200

magmax® egm4050c compact electromagnetic flowmeter dimensions version a type standard: nominal size 10 to 20mm nominal size 25 to 150mm 157 157 20 26 40 230 20 26 230 101 h3 earth ring h grounding terminal m5 grounding terminal m5 h2 h3 h2 earth ring h1 h 101 40 w l flow direction standard l w flow direction standard nominal size 200 to 1000mm 157 20 26 230 101 40 earth ring h h2 h3 grounding terminal m5 l w flow direction standard tg-f1137-2e tokyo keiso co ltd

magmax® egm4050c compact electromagnetic flowmeter dimensions(mm) nominal size mm l jis 10k 156 156 156 156 156 206 206 206 256 256 306 356 406 506 506 606 606 606 606 706 806 906 1006 10 15 20 25 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000 h ※1 asme 150 156 156 156 156 156 206 206 206 256 256 306 356 406 506 708 806 806 806 806 ̶ ̶ ̶ ̶ jis 10k 269 269 269 247 262 281 290 303 333 367 398 465 521 568 613 674 729 783 898 1011 1125 1227 1337 asme 150 269 269 269 239 256 280 291 305 342 369 397 471 524 587 634 692 736 794 906 ̶ ̶ ̶ ̶ mass kg h1 h2 h3 w 62 62 62 ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ ̶ 152 152 152 130 137 149 153 155 173 187 203 209 230 255 277 303 328 354 409 468 524 576 628 207 207 207 185 192 204 208 210 228 242 258 300 321 346 368 394 419 445 500 559 615 667 719 121 121 121 90 105 120 140 150 175 210 240 291 331 381 428 483 533 585 694 812

magmax® egm4050c compact electromagnetic flowmeter model code ● nominal size 10 to 150mm model egm4050c primary head spec code v n 0 3 4 primary head code v n 0 3 fixed code 4 nominal size 0 1 k 1 3 5 abmn 9 fixed code type 0 1 k 2 s lining ※4 1 b 4 5 6 7 n u material of electrode electrode construction 1 1 3 material of primary head housing and flange protection class fixed code calibration 0 0 0 0 hklmn 9 material of earth ring fixed code special feature converter spec code v n 3 4 4 4 converter code v n 3 4 fixed code 4 type 4 power supply fixed code cable entry fixed code orientation of indicator installation special feature 0 2 0 0 0 0 0 0 1 2 3 4 6 7 8 abcd flange fixed code output type fixed code 0 0 0 0 0 6 0 0 description flange type always 4 standard lining jis10k ※2 10mm ※1 ptfe 15mm ptfe 20mm ptfe 25mm pfa 40mm pfa 50mm pfa 65mm pfa 80mm pfa 100mm pfa 125mm pfa 150mm pfa din pn16 din pn40 asme class 150 asme class 300 jis 20k jis

magmax® egm4050c compact electromagnetic flowmeter ● nominal size 200 to 600mm model egm4050c  primary head spec code v n 0 4 4 primary head code v n 0 4 fixed code 4 nominal size 0 1 k 1 0 0 0 0 0 2 0 0 0 0 0 0 efghklmn 2 3 4 5 abmn 9 flange fixed code type 0 1 k 0 2 lining ※4 1 b 4 5 6 7 n u material of electrode electrode construction 1 1 3 material of primary head housing and flange protection class fixed code calibration 0 0 0 0 hklmn 9 material of earth ring fixed code special feature converter spec code v n 3 4 4 4 converter code v n 3 4 fixed code 4 type 4 power supply fixed code 0 6 0 0 2 1 0 0 0 0 0 1 a 0 4 5 6 cable entry fixed code orientation of indicator installation fixed code output type fixed code special feature description flange type always 4 standard lining(jis10k) ※2 200mm etfe 250mm etfe 300mm etfe 350mm etfe 400mm etfe 450mm etfe 500mm etfe 600mm etfe din pn10 din pn16 din pn25 din pn40 asme class 150 asme class 300

magmax® egm4050c compact electromagnetic flowmeter ● nominal size 700 to 1000mm model egm4050c primary head spec code v n 0 5 4 primary head code v n 0 5 fixed code 4 nominal size 0 1 k 1 0 0 0 0 0 2 0 0 0 0 0 0 prst flange 2 3 a n 9 fixed code type lining ※4 0 1 k 0 1 b 4 5 6 7 n u material of electrode electrode construction 1 1 3 material of primary head housing and flange protection class fixed code calibration 0 0 0 0 hkln 9 material of earth ring fixed code special feature converter spec code v n 3 4 4 4 converter code v n 3 4 fixed code 4 type 4 power supply fixed code cable entry fixed code orientation of indicator installation fixed code output type fixed code special feature 0 6 0 0 description flange type always 4 standard lining(jis10k) ※2 700mm etfe 800mm etfe 900mm etfe 1000mm etfe din pn10 din pn16 asme class 150 jis 10k others always 0 compact type egc010 converter etfe stainless steel ss316 hastelloy® c22 hastelloy® b2

magmax® egm4050c compact electromagnetic flowmeter standard accessories ● parameter sheet :1 ● instruction manual :1 ● magnet for data setting 1 option ● ● gwatertight gland for g1/2 female threads wg anti-condensation hc the sealing between the converter and the primary head will be reinforced with silicone potting ordering please specify the following when ordering 1 model and specification codes example model egm4050c primary head spec code vn0347n01ksb110000h02000000 converter spec code vn3444a05600a2100000 2 full scale flow range not necessary for option /ns 3 optional specifications if necessary please specify desirable options with symbols with reference to the above section 4 name of process fluid specification is subject to change without notice head office shiba toho building 1 – 7 – 24 shibakoen minato-ku tokyo 105 – 8558 tel +81-3 – 3431 – 1625 key fax +81-3 – 3433 –