magmax® egm4050c compact electromagnetic flowmeter accuracy ✽3 ● indication and pulse output for velocity ≥ 0.5m/s ±0.5 of reading error ± of reading for velocity 0.5m/s velocity error ± 2.5mm/s 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 0.5 1 2 12 flow velocity m/s ● current output add ±0.01ma to the accuracy of indication or pulse output ✽3 basic conditions fluid water fluid temperature 10 to 30ºc conductivity 150μs/cm or more supply voltage rated voltage ± 2 ambient temperature 18 to 28ºc upstream/downstream straight run 10d/2d d diameter warm-up time about 10 minutes measuring time 100s fluid temperature and pressure range fluid temperature lining material pfa ptfe etfe nominal size(mm) 25 to 150 10 to 20 200 to 600 200 to 1000 fluid temperature ambient temperature −40 to +140℃ −40 to +65℃ −40 to +120℃ allowable maximum pressure and negative pressure lining material pfa ptfe etfe nominal size (mm) allowable allowable negative pressure kpa abs at respective fluid temperatures maximum 40℃ 60℃ 80℃ 100℃ 120℃ pressure mpa※ 25 to 150 5 0 0 0 0 0 10 to 20 5 0 0 0 0 50 200 to 300 5 50 75 100 100 100 350 to 600 5 80 100 100 100 100 200 to 1000 15 10 10 10 10 10 ※values in the table are the maximum pressure for the main body rated pressure for flanges prevails over the allowable maximum pressure tg-f1137-2e tokyo keiso co ltd 3