EGM5300C MAGMAX Electromagnetic Flowmeter 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | EGM5300C MAGMAX Electromagnetic Flowmeter 2017 | 8 pages | 2017-04-06

Ads

Page 3 of EGM5300C MAGMAX Electromagnetic Flowmeter 2017

magmax® compact electromagnetic flowmeter egm5300c ● double range measurement function possible range setting range ratio 1 20 to 1 1.25 accuracy 6 ● setting range of low range 5 to 80 of high range [size 2.5 to 6mm range selection by automatic or control input signal ● indication and pulse output for velocity ≥ 1m/s ±0.5 of reading excitation current frequency switching function for velocity 1m/s ±0.4 of reading velocity error of standard mode ±0.001m/s 1/6 of supply frequency standard [size 10 to 100mm high frequency mode for velocity ≥ 0.33m/s ±0.5 of reading 1/50 to 2 of supply frequency for slurry pulsating flow for velocity 0.33m/s ±0.2 of reading velocity error of etc 5 ● ±0.001m/s self diagnosis function 2.0 functional diagnosis coil disconnection cpu memory software output module and output connection status diagnosis velocity distribution linearity magnetizing current frequency empty detection over range counter over error ± of reading the following conditions are indicated by error message flow and power fail detection ● size 10mm or more 1.5 size 6mm or less 1.0 0.5 0.0 0.0 memory save function for power fail 0.5 1.0 operation parameters and totalization figures are stored for more than 10 years by eeprom non volatile memory ● ● arbitrary output 0.0 to 22.0 ma pulse output test arbitrary output 1hz to 10khz status output test on off ● ● touch sensor setting function infrared radiation additional error of ±0.01ma be added onto displey and 6 basis condition fluid water fluid temperature 10 to 30ºc conductivity 150μs/cm or more supply voltage rated voltage ±2 ambient temperature 18 to 28ºc upstream downstream pipe length 10d 2d d diameter by four infrared sensors data setup from exterior is pos warm-up time about 10 minutes sible without removing cover measuring time 100s hart communication please confirm the specification to us operating range for the earth ring gaskets 5 it can be changed for every application such as slurry and a pulsating flow explosionproof specification ● 12 pulse output simulating output function for current and pulse output is current output test 2.0 current output testing function integrated 1.5 velocity m/s atex [eu atex directive 94/9/ec fluid pressure gasket ptfe jac ket type with joint sheet core equivalent to valqua no n7035 fluorocarbon resin equivalent to valqua no 7020 tantalum earth ring ptfe jac ket type gasket with viton core fluid temperature 1.5mpa 140˚c 4mpa 140˚c 0.7mpa 140˚c flow range possible setting range m3/h nominal size mm tg-em148e-3 min max flow velocity 0 to 0.3 m/s flow velocity 0 to 12 m/s 2.5 0 0.0054 0 0.212 4 0 0.0136 0 0.542 6 0 0.0306 0 1.22 10 0 0.0849 0 3.39 15 0 0.191 0 7.63 25 0 0.531 0 21.2 40 0 1.36 0 54.2 50 0 2.13 0 84.6 80 0 5.43 0 217 100 0 8.49 0 339 tokyo keiso co ltd 3