FKE・・・5 Level Transmitter 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | FKE・・・5 Level Transmitter 2017 | 12 pages | 2017-04-04

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

Catalog FKE・・・5 Level Transmitter 2017

hexagon socket head cap screws socket head cap screw 316 stainless steel socket head cap screw socket head cap screw socket head cap screw 1 x 2 head socket head cap screw socket head cap screws socket head cap screw 14 x 2 socket head cap screw 2 12 13 x 3 socket head cap screw socket head cap screw 12 12 x 6 h 11 socket head cap screw socket head cap screw 2 in socket head cap screw 1 2 13 x 10 316l stainless steel 316l stainless steel bolt 316 stainless steel 304 stainless steel stainless steel bolt nut stainless steel nuts stainless steel 4 bolts stainless steel bolts stainless steel bolt 304 stainless steel bar stainless steel housing stainless steel bolt caps 316 stainless steel plate hexagon head cap screw socket head cap nut alloy steel bolt and nuts 14 x 2 stainless steel bolt 316 stainless steel plug bolts and nuts bolt and nut bolt and nuts bolts and nut jis bolt and nut plate stainless steel stainless steel pressure housings screw bolt and nuts socket head cap die cast aluminum screw socket head cap stainless steel filter housing uses stainless steel filter housing rings on bolts and nuts t bolts and nuts specifications level transmitter differential pressure transmitter capacitive level sensors signal level meter jis 10k jis 10k flange din pn40 steel 316l

FKE・・・5 Level Transmitter 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of FKE・・・5 Level Transmitter 2017

fke 5 level transmitter the fcx-aiii level transmitter accurately measures liq­uid level and transmits a proportional 4 to 20ma signal the transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor tech­n ology to provide exceptional performance and functionality features 1 high accuracy 0.2 accuracy for all calibrated spans is a standard feature for all models covering 0.32kpa {3.2mbar range to 500kpa {5bar high differential pressure range 0.1 accuracy is available as option fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibra­ tion ranges without additional adjustment 2 minimum environmental influence the “advanced floating cell” design which protects the pressure sensor against changes in tempera­t ure static pressure and overpressure substantially re­d uces total measurement error in actual field applications 3 fuji/hart® bilingual communications

fke 5 level transmitter process load limitations see figure below code in the 13th digit of “code symbols” [Ω load resistance 2000 1474Ω 1500 e-10.5 r imax+0.9x10-3 1000 577Ω 500 0 10 hazardous locations see table 2 zero/span adjustment zero and span are adjustable from the hhc1 zero and span are also adjustable externally from the adjustment screw damping adjustable from hhc or local configurator unit with lcd display the time constant is adjustable between 0.06 to 32 seconds zero elevation/suppression −100 to 100 of url normal/reverse action selectable from hhc1 indication analog indicator or 5-digit lcd meter as specified burnout direction:selectable from hhc 1 if self-diagnostic detect transmitter failure the analog signal will be driven to either “output hold” “output overscale” or “output underscale” modes “output hold” output signal is hold as the value just before failure happens

fke 5 level transmitter performance specifications physical specifications reference conditions silicone oil fill 316ss isolating diaphragms 4-20 ma analog output in linear mode accuracy rating including linearity hysteresis and re­ peatability standard for spans greater than 1/10 of url ±0.2 of span for spans below 1/10 of url electrical connections g 1 2 1 2 -14 npt pg13.5 or m20 x 1.5 conduit as specified process connections lp side 1/4-18 npt or rc1/4 hp side ansi din or jis raised face flange see outline diagram for detailed dimensions refer to “code symbols” process-wetted parts material ± 0.1 0.1 0.1 × url span of span option code 21th digit h k for span greater than 1/10 of url 0.1 of span for span below 1/10 of url 0.1 × url ± 0.05 0.05 span of span stability ±0.2 of upper range limit url for 10 years temperature effect effects per 28°c change between the limits of −40°c and +85°c url x url total effect ± 0.5 x

fke 5 level transmitter optional features accessories indicator oval flanges converts process connection to ½-14 npt or to rc½ in carbon steel or in 316 stainless steel hand held communicator handy type communicator with built in battery a plug-in analog indicator 2.5 accuracy an optional 5-digit lcd meter with engineering unit is also available local configurator with lcd display an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw arrester a built-in arrester protects the electronics from lightning surges lightning surge immunity 4kv1.2 × 50µs oxygen service special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free the fill fluid is fluorinated oil chlorine service oil-free procedures as above includes fluorinated oil for fill degreasing process-wetted parts are cleaned but the fill fluid is standard silicone oil not for use on oxygen or chlorine measurement vacuum

fke 5 level transmitter code symbols 1 2 3 4 5 6 7 8 digit 4 5 6 7 note description

fke 5 level transmitter 1 2 3 4 5 6 7 8 digit description note

fke 5 level transmitter 1 2 3 4 5 6 7 8 digit 14 15 21 description

fke 5 level transmitter outline diagram unit:mm vjp chr 5 dm et sw

fke 5 level transmitter outline diagram unit:mm vjp chr 5 dm et 5 8

fke 5 level transmitter outline diagram unit:mm b l 5 u sw

fke 5 level transmitter outline diagram unit:mm b l 5 u 5 8

fke 5 level transmitter table 2 authorities atex authorities intrinsic safety ex ii 1 g ex ia iic t5 tamb –40°c to +50°c ex ia iic t4 tamb –40°c to +70°c entity parameters ui=28v ii=94.3ma pi=0.66w ci=26nf without arrester li=0.6mh without analog indicator ci=36nf with arrester li=0.7mh with analog indicator factory mutual 13th digit y,g,h,j,s,t,k y,g,h,j,s,t,k y,g,h,j,s,t,k y,g,h,j,s,t,k w,a,d tamb −40°c to +85°c −20°c to +80°c −20°c to +60°c −40°c to +60°c −10°c to +60°c entity parameters vmax=28v imax=94.3ma pi=0.66w ci=35.98nf li=0.694mh csa ex ii 2 gd ex d iic t6 ip66/67 t85°c tamb −40°c to +65°c ex d iic t5 ip66/67 t100°c tamb −40°c to +85°c factory mutual class i div.1 groups b c d t6 type 4x class ii iii div.1 groups e f g t6 type 4x tamb max +60°c csa class i div.1 groups c d class ii div.1 groups e f g class iii div.1 note “seal not