FKX・・・5 DP Transmitter (Small Flange Remote Seal Type) 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | FKX・・・5 DP Transmitter (Small Flange Remote Seal Type) 2017 | 15 pages | 2017-04-04

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

FKX・・・5 DP Transmitter (Small Flange Remote Seal Type) 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of FKX・・・5 DP Transmitter (Small Flange Remote Seal Type) 2017

fkx 5 small flange remote seal type differential pressure transmitter physical specifications optional features electrical connections g 1 2 1 2 -14 npt pg13.5 or m20 × 1.5 conduit as specified process connections jis 10k 20k 30k 40 50a 10k 20k 30k 15 20a with adapter ansi/jpi 150lb 300lb -11/2 2 150lb 300lb 1/2 3/4 with adapter screw connection with adapter rc1/2 rc3/4 1/2 14npt 3/4 14npt diaphragm extension 0 50 100 150 or 200mm as specified see model code extended diaphragm is available only with 316l stainless steel diaphragm process-wetted parts material diaphragm 316l stainless steel ma276 monel or tantalum flange face 316 stainless steel ma276 lining monel lining or tantalum lining extension 316 stainless steel indicator filled liquid silicone code y,g [kpa abs {m bar abs silicone code s 101 {1010 operating pressure non-wetted parts material electronics housing low copper die-cast aluminum alloy finished with polyester coating standard or 316 stainless steel

fkx 5 small flange remote seal type differential pressure transmitter code symbols 1 2 3 4 5 6 7 8 digit 4 5 6 7 description

fkx 5 small flange remote seal type differential pressure transmitter 1 2 3 4 5 6 7 8 digit 9 10 11 12 13 14 description

fkx 5 small flange remote seal type differential pressure transmitter specifications of connecting pipe less adapter {for 15 20a 1/2 3/4” connection and others note 1 when odering the instrument with connecting pipe less adapter specify “y” in the 5th digit of code symbol and specify 16th digit to 20th digit when odering the instrument without connecting pipe less adapter nothing should be filled in the 16th to 20th digit 2 unless otherwise described in the specifications leave the 21st digit blank 1 2 3 4 5 6 7 8 digit description 16 17

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm s v 0~7 tw a~x

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm s v y tw

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm s v y tw in case of 4th digit code s v w zero adj screw in case of 4th digit code t b conduit conn 38 u-bolt m8 57 103 φ81 103 8 10 mtg pipe jis 50a 2b 1 2 3 5 φ81

fkx 5 small flange remote seal type differential pressure transmitter outline diagram unit:mm 5 7 y 6 8

fkx 5 small flange remote seal type differential pressure transmitter table 2 authorities atex intrinsic safety authorities ex ii 1 g ex ia iic t5 tamb –40°c to +50°c ex ia iic t4 tamb –40°c to +70°c entity parameters ui=28v ii=94.3ma pi=0.66w ci=26nf without arrester li=0.6mh without analog indicator ci=36nf with arrester li=0.7mh with analog indicator factory mutual model code 13th digit tamb a,b,c,d,j y,g,h,s −40°c to +85°c l,p,m,1,2,3 y,g,h,s −20°c to +80°c q,s,n,4,5,6 y,g,h,s −20°c to +60°c e,f,g,h,k y,g,h,s −40°c to +60°c w,a,d −10°c to +60°c entity parameters vmax=28v imax=94.3ma pi=0.66w ci=35.98nf li=0.694mh csa class i div.1 groups a b c d class ii div.1 groups e f g class iii div.1 temp code t5 tamb max +50°c temp code t4 tamb max +70°c entity parameters vmax=28v imax=94.3ma ci=25nf without arrester ci=36nf with arrester li=0.6mh without analog meter li=0.7mh with analog