FKY・・・5 Level Transmitter (Small Flange Type) 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | FKY・・・5 Level Transmitter (Small Flange Type) 2017 | 8 pages | 2017-04-03

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

Catalog FKY・・・5 Level Transmitter (Small Flange Type) 2017

hexagon socket head cap screws socket head cap screw flange stainless steel socket head cap screw low socket head cap screw stainless extra low socket head cap screw socket head cap screw low socket head cap screw socket head cap screw low head low head socket head cap screw socket head cap screw 1 x 2 6 mm socket head cap screw 6 mm socket head cap screws head socket head cap screw socket head cap screws h 11 socket head cap screw 13 x 3 socket head cap screw socket head cap screw 14 x 2 26 x 8 mm socket head cap screws socket head cap screw 2 12 socket head cap screw 12 12 x 6 12 mm socket head cap screws 10 mm socket head cap screws 15 mm socket head cap screw socket head cap screw 1 2 13 x 10 socket head cap screw 2 in material for socket head cap screw 316l stainless steel 316 stainless steel 304 stainless steel stainless steel bolt nut stainless steel nuts stainless steel 4 bolts stainless steel bolts stainless steel bolt 304 stainless steel bar stainless steel bolt caps hexagon head cap screw plate stainless steel stainless steel housing socket head cap nut 316 stainless steel plug alloy steel bolt and nuts 14 x 2 stainless steel bolt jis bolt and nut 316 stainless steel plate bolts and nuts bolt and nut stainless steel pressure housings bolt and nuts bolts and nut socket head cap die cast aluminum screw bolt and nuts rings on bolts and nuts t screw socket head cap

FKY・・・5 Level Transmitter (Small Flange Type) 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of FKY・・・5 Level Transmitter (Small Flange Type) 2017

fky 4 small flange level transmitter general the fcx–a2 small flange level transmitter accurately measures liquid level and transmits a proportional 4 to 20ma signal the transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality features specifications functional specifications service liquid gas or vapour static pressure span and range limit static pressure type fky 5 fky 6    ❏ directly connectable to 1-1/2 in and 2 in flanges the transmitter is connectable to 1-1/2 in and 2 in pipes without a reducer ❏ minimum environmental influence the advanced floating cell design which protects the pressure sensor against changes in temperature static pressure and overpressure substantially reduces total measurement error in actual field applications ❏ hart® communications protocol and foundation™ fieldbus and profibus™

small flange level transmitter fky 4 load limitations see figure below temperature limit ambient – 15 to 65°c – 15 to 65°c for lcd indicator – 15 to 60°c for arrester option – 10 to 60°c for fluorinated oil fill transmitter – 10 to 60°c for silicon oil h s for explosionproof units flameproof or intrinsic safety ambient temperature must be within the limits specified in each standard process [Ω load resistance 2000 1533Ω 1500 1000 600Ω operating area 500 24v 250 10 45v 16.1 10.5v power voltage 50 fill fluid 13th digit of code symbols fluorinated oil w a and d silicone oil h [v note for communication with hhc1 model fxw min of 250Ω required y and g s hazardous locations approval pending authorities flameproof intrinsic safety atex factory mutual ex ii 2 gd eexd iic t5/t6 class i ii iii div 1 groups b thru g ex do iib+h2 t4 ex ii 1 gd eexia iic t4/t5 class i ii iii div 1 groups a thru f ex ia ii c t4

small flange level transmitter fky 4 performance specifications reference conditions silicone oil fill 316ss isolating diaphragms 4-20 ma analog output in linear mode accuracy rating including linearity hysteresis and repeatability standard for spans greater than 1/10 of url ± 0.25 of span for spans below 1/10 of url ± 0.17 0.08 0.1 x url span of span option code 21th digit h k for spans greater than 1/10 of url ± 0.1 of span for span below 1/10 of url ± 0.05 0.05 0.1 x url span of span ± 0.2 of upper range limit url for 3 years temperature effect effects per 28°c change between the limits of – 15°c and 65°c zero shift ± 0.5 28°c x equal to 1/2 url or more url zero shift ± 0.5 28°c 2x 1 x less than /2 url total shift ± 0.75 28°c x equal to 1/2 url or more url total shift ± 0.25 +0.5 × 28°c 2x x less than 1/2 url stability option code 21th digit j k zero shift ± 0.5 28°c x equal to 1/6.5 url or more url

small flange level transmitter fky 4 mass{weight transmitter approximately 13kg without options add 0.8kg for indicator option 4.5kg for stainless steel housing option 1.0kg per 50mm extension of diaphragm optional features indicator a plug-in analog indicator 1.5 accuracy can be housed in the electronics compartment or in the terminal box of the housing an optional 5-digit lcd meter with engineering unit is also available arrester a built-in arrester protects the electronics from lightning surges lightning surge immunity 4kv 1.2 x 50µs oxygen service special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free the fill fluid is fluorinated oil chlorine service oil-free procedures as above includes fluorinated oil for fill degreasing process-wetted parts are cleaned but the fill fluid is standard silicone oil not for use on oxygen or chlorine measurement vacuum service special silicone oil and filling procedure are applied see

small flange level transmitter fky 4 code symbols 1 2 3 4 5 6 7 8 digit 4 5 6 7 9 description note

small flange level transmitter fky 4 1 2 3 4 5 6 7 8 digit 10 11 12 13 14 15 21 description note

small flange level transmitter fky 4 outline diagram unit:mm 7th digit code v c d e h m or t note2 vent drain plug when the vent drain plug attatched on the upper side of the detector in case of 4th digit code s v w x 10 zero adj screw 43.5 105 52.5 fastener flameproof only n holes h dia up ø80 a l p conn ø80 b conduit conn.2 in case of frange with 4 bolt holes 88 down l2 note cable grand option l1 oval flange screw see table 1 detail a ø7 detail b ø15 detail c ø13 m k 8 2.5 43 ød øe øf ø49 ø48 h ø18.5 h.p conn l3 17 l.p conn 41.3 27 t 48 l 20 with field ind b conduit conn.1 143 vent drain plug c conduit conn 27 j g1/2 see table 1 inner of gasket sensor unit electronics unit l 11th digit of code symbols [mm ød 0 g 140 105 36 4-19 jis-10k-40a 1 h 155 120 36 4-19 jis-10k-50a øe t n-øh flange 5 4.5 16 5 8 4.5 4-19 jis-20k-40a 8-19 jis-20k-50a d w m20 e x pg13.5 4-23 jis-30k-40a 8-19 jis-30k-50a 98.4 37.5 127 b

small flange level transmitter fky 4 7th digit code b l or u oval flange screw see table 1 in case of 4th digit code s,v,w x 41.3 n holes h dia 28 115 ø80 52.5 up 107 fastener flameproof only ø80 zero adj screw 43.5 c conduit conn 2 a or b l p conn 10 in case of flange with 4 bolt holes 88 down 150 note 27 323 vent drain plug cable grand option t details of a 4th of code symbols a s type 20 ø16 details of b 4th of code symbols b c d e t v w x type ø16 1/4 -18npt 0 2 –0.1 –0.2 ø12+0.1 10 1 40.5 43 91 186 h.p conn ød øe øf ø49 d conduit conn with field ind c conduit conn 1 286 inner of gasket ø4 earth terminal detail c sensor unit detail d ø13 electronics unit m ø15 t n-øh flange 17 øe k 5th digit of code ød symbols 0 g 140 105 36 4-19 jis-10k-40a 1 h 155 120 36 4-19 jis-10k-50a 2 j 140 105 39 4-19 jis-20k-40a 3 k 155 120 38 8-19 jis-20k-50a 4 l 160 120 42 4-23 jis-30k-40a 5 m 165 130 42 8-19