FS Series Spring Balanced, Displacement type Level Transmitter / Indicator 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | FS Series Spring Balanced, Displacement type Level Transmitter / Indicator 2017 | 7 pages | 2017-04-03

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

FS Series Spring Balanced, Displacement type Level Transmitter / Indicator 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of FS Series Spring Balanced, Displacement type Level Transmitter / Indicator 2017

fs series spring balanced displacement type level indicator transmitter outline fs series detects and indicates liquid level by spring balanced displacer along with local level indication by pointer dial alarm contacts pneumatic output or electiric outout can be provided for versatile application standard specifications mechanical portion detection method by spring balanced displacer measuring range min.300mm suitable liquid density standard range 0.7 to 1.3g/cm3 max.3000mm other density range available on request however size of connection flanges may differ from standard sizes viscosity max 600 mpa·s liquid without sticking crystallization or freezing installation and connection flange size a without chamber fig.1 or welding type internal liquid temperature chamber fig.2 measuring range upto 1000mm 4” flange standard measuring range more than 1000mm 3” flange with radiation fin –40 to –11°c low temp version +151 to +350°c high temp version

fs series 45 50 $0 2 4 $0 1 5&3 $0 3 6 50/r13&4463&r $0 50 4 f4 – 1 basic code 2 installation code 1 1 3 5 5 function 1 1 1 1 1 0 5 3 2 7 construction local indication 1 alarm contact s pneumatic output 1 electric output electric +contact s 1 w weather proof e flameproof 2 s intrinsically safe 1 2 3 chamber 4 construction 5 6 9 without chamber welding type internal chamber bolt-on internal chamber insertion type internal chamber side~side external chamber side~bottom external chamber special design fig.1 fig.2 fig.3 fig.4 fig.5 fig.6 1 explosion-proof structure only 2 intrinsically safe apply only fs-115s-type 3 material code spring displacer 6 c e 9 sus316 uns n10276 inconel others sus304 sus316 sus316l others 4 6 l 9 upper flange chamber 4 function • pressure • connection s 4 6 l 9 s 4 6 l 9 1 1 1 function 1 2 2 carbon steel sus304 sus316 sus316l others carbon steel sus304 sus316 sus316l others without chamber press rating process flange size l m

fs series output 5 463 3 6 option 7 5 output 7 option indicate necessary options by the following abbreviations 0 1 2 3 4 output 5 signal 6 7 8 a z entry 1 2 3 4 9 nil 1 point 2 points 3 points 4 points 5 points 6 points 20 to 100 kpa 0 to 100 0.2 to 1.0 bar g 0 to 100 4 to 20 ma dc 0 to 100 others rc pt female npt female g pf female npt female others for fs-110 cg pressure tight cable gland 1 cf radiation fin as air set filter regulator for fs-313 for fs-115 fs-517to two points vp vent plug for fs-313 for fs-512/fs-517 vs volume graduation 2 ss special graduation 2 hs liquid height graduation bs no indication blind plate sc special color paint for fs-313 for fs-115/fs-512 fs-517 dv drain valve material as per chamber material 1 specify external diameter of cable 2 specify graduation heght~volume etc 6 measuring range 1 300mm 2 500mm 3 800mm 4 1000mm 5 1200mm measuring 6 1500mm range 7 1800mm 8 2000mm 9 2500mm a 3000mm z order made specify measuring range in

fs series dimensions fig 1 without chamber fig 2 welding type internal chamber fig 3 fig 4 bolt-on internal chamber insertion type internal chamber standard dimension table measuring range mm h ff ød øe a1 a2 a3 5 5 6 450 89.1 300 650 500 4 4 5 76.3 950 800 1000 1150 60.5 1200 1350 11/2 1500 1650 48.6 1800 1950 3 3 4 42.7 2000 2150 2500 2650 34.0 3000 3150 refer to fig.1 to 6 for signs values in the table are for measuring the level of liquids with a standard density they may differ when measuring the level of liquids with a non-standard density or measuring the interface of two liquids 4 fig 5 fig 6 side to side external chamber side to bottom external chamber tokyo keiso co ltd

fs series transmitters specification 1 alarm contact fs-115 ■ construction weather proof flameproof intrinsically safe ip54 equ fs-115w d2g4 fs-115e ex ia iic t6 fs-115s with intrinsically safe relay fig 9 fs-115w/s 3 to 6 points number of contact lowest position highest position min point inteval max 6 points higher than 10 of full span lower than 90 of full span higher than 10 of full span contact setting accuracy ±1.0 f.s against local indication switching hysteresis 10 f.s switch microswitch spdt contact capacity 250 v ac 5a resistance load 125 v dc 0.4a resistance load minimum applicable load 5 v dc 160ma ambient temp weather proof fs-115w –25 to +60°c flameproof fs-115e –10 to +60°c intrinsically safe fs-115s –10 to +40°c provide heat insulation if required cable entry no of alarm point connection size no of connection 1 2 3 4 1/2b 1 5 3/4b 1 fig 10 fs-115e 3 and 6 points fs-115w/s for 1 point alarm for 2 points alarm for

fs series 2 pneumatic transmitter fs-313w construction input output weather proof ip54 equ 0.14±0.01mpa standard 0.2 to 100kpa option 0.2 to 1.0bar output accuracy ±1.0 f.s against local indication air connection standard 2 × rc 1/4 pt1/4 option 2 × npt1/4 female input and output pressure gauges provided ambient temp –20 to +80°c option 1 air set filter regulator input max 990kpa g1/2 or 1/2”npt fig 13 indicator and transmitter assembly fs-512w and fs-512e external dimension of indicator and pneumatic transmitter 4 to 20 ma dc 12 to 30 v dc load max 600Ω at 24 v dc fig 14 terminal arrangement fs-512w and fs-512e fig 12 fs-313w air set option 4 electric transmitter and alarm contact fs-517 ■ 3 electric transmitter fs-512 ■ construction wether proof fs-517w ex-d version is not available maximum alarm contact is 2 points specification for alarm contact is as of fs-115 specification for analog output is as of fs-512 refer to

fs series supply scope 1 blots nuts and gaskets for process connection are customer’s scope of supply 2 standard accessories special tool for explosion proof housing instruction manual ordering form specify the following for order or inquiry 1 tag.no 2 model code fs – 3 liquid name 4 density 5 viscosity 6 pressure 7 vapour density 9 measuring range – – – – mpa temperature nor 8 – max °c °f mm inch h1 h2 alarm setting point and action 10 h3 h4 h5 h switch action hc ho lc lo h1 h2 h3 h4 h5 h6 550 h6 11 special note specification is subject to change without notice head office shiba toho building 1 – 7 – 24 shibakoen minato-ku tokyo 105 – 8558 tel +81-3 – 3431 – 1625 key fax +81-3 – 3433 – 4922 e-mail overseas.sales@tokyokeiso.co.jp url http www.tokyokeiso.co.jp tg-l541-10e tokyo keiso co ltd