Catalog MASSMAX 3300 SeriesCoriolis Mass Flowmeter 2017

1 inch npt female adapter pipes stainless steel 316l stainless steel tubing pressure rating tubing stainless steel housing stainless steel stainless steel terminal tube fittings stainless steel pressure and temperature sensors fittings stainless steel fitting stainless steel stainless steel tube in tube sizes of stainless steel tubing fittings pipe to pipe fittings sizes of stainless steel fittings 2 12 inch by 3 inch 90 mass flow mass flow sensor steel 316l explosion proof 316l stainless steel 316l stainless steel tubing 316l stainless steel tube ambient temperature sensor cable gland bursting disc cable glands adapter npt female 316l stainless steel plates sensor temperature female female adapter female adapter female adapters terminal block earth cable terminal blocks explosion proof fittings terminal block 3 p 316l sanitary stainless steel tubing max flow sensor cable stainless steel tubing burst pressure tube female pipe female tubes stainless 316l stainless steel pipe 316l stainless steel sheet 316l stainless steel pipes npt pipe fittings pipe fittings npt infra red sensor 3 inch pipe 6 inch pipe 1 inch pipe outside diameter temperature rating safety burst disc

MASSMAX 3300 SeriesCoriolis Mass Flowmeter 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of MASSMAX 3300 SeriesCoriolis Mass Flowmeter 2017

massmax® 3300 series coriolis mass flowmeter single measuring tube for small flow general the coriolis mass flowmeter massmax® 3300 series consists of the single z-shaped measuring tube which is well-accepted as very small flow measurement and newly-developed high performance converter mmc300 the easy-to-use and high-performance converter mmc300 has enhanced various features such as touch sensor operation and selfdiagnosis functions the epoch-making sensing technologies have achieved the accurate flow measurement of very small flow rate with a wide rangeability stainless steel 316l as standard and hastelloy® c22 as an option are used for the wetted parts of the flowmeter with 3 sizes of 1 3 and 4mm massmax® 3300 is suitable for the accurate measurement of very small flow rate as low as 1 kg/h or less features ❏ ❏ ❏ ❏ ❏ ❏ single z-shaped measuring tube standard tube pressure rating 15mpa high accuracy ±0.1 of reading zero stability

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter converter ● ● ● ● ● ● ● ● housing material aluminum alloy ss316l as an option painting siloxane coating color grey converter housing jade green converter cover terminal box cover power supply 100v to 230vac 85v to 253vac option 24vdc 9 to 31vdc voltages in are acceptable supply frequency 48 to 63 hz power consumption ac approx 28 va dc approx 12 w grounding grounding resistance must be less than 100Ω for non-ex version 10Ω for ex version cable entry 2×g1/2 female adapter or 2×1/2 npt female adapter or 2×1/2 flame proof adapter for tiis-ex note maximum 3 cable entries can be provided ● ● indication and outputs ● ● ● ● 2 indicator blue dot matrix lcd with back light 128×64 pixels or 59×31 mm presentation changeable from 2 screens each screen shows maximum 3 lines of data the

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter accuracy calibrated at the factory explosion proof ● ● mass flow pulse output 1 compact type sensor-converter integrally mounted compact type ±0.1 of reading accuracy model ±0.0057 of nominal max flow rate zero stability tiis technology institute of industrial safety in japan mmm3300c-jex type of protection and class note the figures of accuracy and zero stablity above are based on the conditions that measured fluid is water with 20°c and 0.2mpa ex d [ib llc t4/t3 sensor ex ib llc t4/t3 [measuring error accuracy zero stability converter ex d [ib llc t4/t3 certified no measuring error of reading 0.6 no tc18179 t3 0.5 ambient temperature –20 to +50°c fluid temperature 0.4 ● atex directives 94/9/ec 1 compact type sensor-converter integrally mounted compact type 0.2 model 0.1 0.0 10 20 30 40 50 60 70 80 90 100 flow rate of nominal max flow rate of nominal

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter name of each part compact version converter cable entry power supply front-end input output esc sensor outer housing base plate process connection flow range meter size nominal max flow rate kg/h kg/min 01 20 0.333 03 130 2.166 04 450 7.5 measuring tube dimensions meter size 01 03 04 material measuring tube dimensions mm inside diameter wall thickness 1.20 0.20 2.58 0.30 3.94 0.41 shshsh material s stainless steel 316l h hastelloy® c22 4 tokyo keiso co ltd

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter electrical connection ● 1×current output 1×pulse output 1×status output 1×control converter specifications terminals l– l connection diagram for optional outputs i/o print circuit modules d– – d c– – c – b a a– – a option 3 option 1 option 2 2×current outputs 3×current outputs 2×current outputs 1×pulse or status 1×pulse or status 1×pulse output 1×status output designated output designated or pulse output as 6a8 as 6aa designated as 6ae pulse or status output pulse or status output pulse or status no.1 current output no.1 current output no.1 current output no.1 internal power internal power internal power current output no.2 pulse or status internal power output no.2 current output no.2 current output no.3 current output no.2 internal power internal power internal power a– a b

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter dimensions compact version [mmm3300c mass approx 12kg 260 g 137 82 120 1 length g · 26mm with a g1/2 female adapter · 26mm with a 1/2 npt female adapter · 65mm with a tiis explosionproof type adapter 140 140 38 38 10 76 a-a 60 base plate ✽ 242.5 a 4-ϕ8 for mounting ✽ a 35.5 156 14.5 348 esc 160 228 256±3 180 98.5 132 flow direction standard ✽note the base plate of flowmeter shall be fixed firmly on a pedestal or the like do not support flowmeters by piping or piping fittings sensor of remote type [mms3000f 106 26 58 mass approx 10kg 53 a-a 77 38 50 60 269 base 4-ϕ8 for mounting ✽ a 35.5 156 14.5 a plate ✽ 160 180 98.5 228 132 256±3 flow direction standard ✽note the base plate of flowmeter shall be fixed firmly on a pedestal or the like do not support flowmeters by piping or piping fittings converter of remote type [mmc300f 260 120 140 10 26

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter model and specification code measuring tube material s stainless steel 316l [standard h hastelloy® c22 [option sensor and converter integrally mounted compact type general purpose non explosionproof mmm3300c-◼◻◻ sensor and converter separately mounted remote type product specifications tiis explosionproof mmm3300c-jex-◼◻◻ atex explosionproof mmm3300c-ex-◼◻◻ sensor converter mms3000f-◼◻◻ mfc300f — — mms3000f-ex-◼◻◻ mfc300f-ex note tiis explosionproof version is certified by technology institute of industrial safey in japan material code either s or h is designated in ◼ size code either 01 or 03 or 04 is designated in ◻◻ [sensor code sensor spec code tk sensor code tk meter size 4 0 hk 0 0 01 03 04 fixed code 4 s h measuring tube material measuring tube surface finish process

massmax® 3300 series single measuring tube for small flow coriolis mass flowmeter installation notes observe followings for the installation of massmax® 3300 on the piping ● in both cases of horizontal and vertical installation the base plate of flowmeter shall be fixed firmly on a pedestal or the like by using 4 mounting holes located on the base plate as shown in figure ① below do not support the flowmeter by piping or piping fittings ● install the flowmeter on the vertical piping within the allowable inclination as shown in drawings ② and ③ do not install the flowmeter on the inclined piping ● do not install the flowmeter as note 1 and note 2 below ● arrange the piping so that the measuring tube is filled with fully liquid ● install the control valve at the downstream side of the flowmeter if required to avoid possible cavitation caused by throttling of upstream control valve ① ③ ② ① install the