for high-accuracy measurement of the mass flow of various gases tf-5000/6000 series mass flowmeter outline tf-5000,6000 series are thermal mass flowmeters which measure mass flow rate of various kinds of gas free from the change of process condition such as pressure and temperature tf-5000 6000 cover from 0 to 5 ml/minnor to 0 to 500 l/minnor scale range and maximum 32 mpa pressure to meet almost all possible applications supporting instruments such as power supply unit indicator as well all-in-one panel instrument are available to complete the signal loop features ❏ wide range with the full scale range of 5 ml/minnor to 500 l/minnor and the maximum operation pressure of 32 mpa the mass flowmeter covers a wide range of applications from mounting onto labora model code ❏ high accuracy tf-5000 6000 offer ±1.0 f.s accuracy ❏ high reliability model code tf measurement guarantees reliability and durability size power supply unit indicating unit compact all-in-one panel

tf-5000/6000 series mass flowmeter standard specification model tf-5310 tf-5330 contact us for the applicability of the flowmeter to less common gases min 0 to 5 ml/min nor 0 to 20 l/min nor 0 to 80 l/min nor 0 to 300 l/min nor max 0 to 20 l/min nor 0 to 80 l/min nor 0 to 300 l/min nor 0 to 500 l/min nor output signal accuracy 0 to 5 v dc linear to 0 to 100 of scale range ±1.0 f.s at rt standard rt ambient temperature of 25°c ±5°c at the adjustment response speed 90 within 3sec gas press –0.03 to 0.98 mpa temp range gas ambient 5 to 50°c temp change effect press change effect power supply to detector fittings flanges ±0.1 f.s °c max for zero ±0.05 f.s °c max +15 v dc 25 ma max -15 v dc 5 ma max tube sus316 sealing fkm or cr gas contact threads for span ±0.1 f.s 0.1 mpa max 2 material process connection tf-5340 gases excluding chlorine acid sulfur and other corrosive gases measuring fluid 1 scale range tf-5320 rc1/4 1/4npt rc1/4 3/8 1/2 1/4 3/8

tf-5000/6000 series mass flowmeter model measuring fluid tf-6310 tf-6320 tf-6330 gases excluding chlorine acid sulfur and other corrosive gases contact us for the applicability of the flowmeter to less common gases min 0 to 5 ml/min nor 0 to 20 l/min nor 0 to 80 l/min nor 0 to 300 l/min nor max 0 to 20 l/min nor 0 to 80 l/min nor 0 to 300 l/min nor 0 to 500 l/min nor 1 scale range output signal accuracy 0 to 5 v dc linear to 0 to 100 of scale range ±1.0 f.s at rt standard rt ambient temperature of 25°c ±5°c at the adjustment response speed 90 within 3 sec gas press –0.03 to 32 mpa 4 temp range gas ambient 5 to 50°c temp change effect press change effect power supply to detector for span ±0.1 f.s °c max for zero ±0.05 f.s °c max ±0.1 f.s 0.1 mpa max 2 +15 v dc 25 ma max –15 v dc 5 ma max material tube sus316 sealing fkm or cr gas contact process connection tf-6340 threads rc1/4 1/4npt rc1/4 3/8 1/2 1/4 3/8 1/2npt fittings od1/4 3/8 swagelok

tf-5000/6000 series mass flowmeter dimensions tf-5310 rc connection swl connection vcr connection 2-m4 depth5 2-m4 depth5 2-m4 depth5 size size tf-5320 rc connection jis 10k flange size 2-m4 depth5 2-m4 depth5 size type swl connection 2-m4 depth5 vcr connection jis 10k flange 2-m4 depth5 2-m4 depth5 size size size type 4 tokyo keiso co ltd

tf-5000/6000 series mass flowmeter tf-5330/tf-5340 rc connection swl connection 2-m4 depth6 size 2-m4 depth6 size model model vcr connection jis 10k flange 2-m4 depth6 2-m4 depth6 size size type model model tg-es261-4e tokyo keiso co ltd

tf-5000/6000 series mass flowmeter tf-6310 swl connection tf-6310 rc screw connection mass flow meter type gas flow rate pressure mfg.no gas flow rate pressure mfg.no 124 146 type tokyo keiso co ltd japan tokyo keiso co ltd japan flow 16 2-swl 16 2-rc1/4 flow 124 146 mass flow meter 4-m4depth5 54 26 â–¡32 26 â–¡32 4-m4depth5 15 54 90 15 90 128 l connection 1/4swl 3/8swl l 144 147 tf-6320 swl connection tf-6320 rc screw connection mass flow meter mass flow meter type type 152 174 tokyo keiso co ltd japan flow 152 174 gas flow rate pressure mfg.no gas flow rate pressure mfg.no tokyo keiso co ltd japan flow 2-swl 30 30 2-rc 2-m4depth6 40 â–¡60 40 â–¡60 2-m4depth6 70 70 130 connection rc1/4 rc3/8 rc1/2 6 tokyo keiso co ltd 30 30 130 l connection 1/4swl 3/8swl 1/2swl l 181 184 188

tf-5000/6000 series mass flowmeter tf-6330 swl connection mass flow meter mass flow meter type type gas flow rate pressure mfg.no gas flow rate pressure mfg.no tokyo keiso co ltd japan 194 tokyo keiso co ltd japan flow 2-rc 194 tf-6330 rc screw connection flow 40 40 2-swl 100 60 48 100 196 â–¡80 2-m5depth8 60 â–¡80 2-m5depth8 48 196 l connection rc3/8 rc1/2 connection 1/4swl 3/8swl 1/2swl 3/4swl l 247 250 255 266 tf-6340 swl connection tf-6340 rc screw connection mass flow meter mass flow meter type type gas flow rate pressure mfg.no gas flow rate pressure mfg.no 194 2-swl 40 2-rc tokyo keiso co ltd japan flow 140 236 60 â–¡80 2-m5depth8 60 â–¡80 2-m5depth8 40 194 tokyo keiso co ltd japan flow 48 140 236 l 48 connection rc3/8 rc1/2 tg-es261-4e connection 3/8swl 1/2swl 3/4swl l 290 295 306 tokyo keiso co ltd

tf-5000/6000 series mass flowmeter example of model selection the flow range is indicated as that of n2 gas when measuring other gases use the conversion factors cf shown below to convert the flow rate of the desired gas to that of n2 and confirm that the selected model is appropriate for that measurement formula for single-component gas flow rate of the gas specified by customers flow rate converted to that of n 2 cf of the gas formula for mixed gas gas with two or more components first identify each cf of the component gases calculate the cf of the mixed gas and then convert its flow rate to that of n2 cf of the mixed gas 1 x1 x2 x6 +… cf1 cf2 cf6 x1 :composition ratio of component 1 vol 100 x2 :composition ratio of component 2 vol 100 ⋮ x6 :composition ratio of component 6 vol 100 cf1 :cf of component 1 cf2 :cf of component 2 ⋮ cf6 :cf of component 6 flow rate of the mixed gas specified by customers flow

tf-5000/6000 series mass flowmeter cautions on use • the mass flowmeter outputs flow rate signals from 0 to 100 if the value in the lowest digit fluctuates too much at the zero point set the low-cut at the converter tm-2000 a dedicated converter cuts off values of 2 or less as standard • when fluid flows in the opposite direction the mass flowmeter outputs negative signals to prevent this install a check valve in the down stream of the flowmeter • the flow rate output characteristic of the mass flowmeter has been set to 5.000 [v at the full-scale flow rate if the flow rate exceeds the upper limit the output of the flowmeter rises linearly at first but then declines gradually to prevent this use the flowmeter within the rated flow rates • stop the flow of gas completely before adjusting the zero point for details see the instruction manual • never allow gases that corrode sus316 to flow through the flowmeter because the sensor capillary is made of

tf-5000/6000 series mass flowmeter application examples ❏ direct control by 0 to 5 v dc output ❏ indication mass flow meter ❏ indication totalization mass flow meter type mass flow meter type gas flow rate flow rate flow rate pressure pressure mfg.no mfg.no mfg.no tokyo keiso co ltd japan 0 to v5 dc v dc 0–5 4 to 20 ma dc or 4–20 ma dc type gas pressure gas tokyo keiso co ltd japan tokyo keiso co ltd japan high or low supporting instruments ❏ tcdu indicator unit 21.5 ❏ tcp power supply unit -3 us f -2 e -1 47.5 20p mounting stud 24.5 fuse 4.8 11.8 5 51 u v 44.5 ±0.3 e 44 22±0.3 10p 20p 10p 95 146 max 130 120 136 max panel cutout ambient temp 4-m4 ❏ tm-2000 convertor unit 105 max 80 40 100 100 max 4-m4 60 0 to 50°c 75 l1=120 l2=140 l1=180 l2=226mm for tcp-5 tcp-1 tcp-3 refer to tm-2000 catalog for details ❏ sc connecting cable code sc-tf sc-t sc-d sc-fm2 connection between the tf detector and the commercially available power