UCM-04A/06A Ultrasonic Flowmeter for small liquid flow 2017 by Tokyo Keiso

More catalogs by Tokyo Keiso | UCM-04A/06A Ultrasonic Flowmeter for small liquid flow 2017 | 5 pages | 2017-03-28

Ads

Contacts for Tokyo Keiso

TOKYO KEISO CO.,LTD

· Overseas Sales Dept.
Phone : 03-3431-1625
Fax : 03-3433-4922
E-Mail : overseas.sales@tokyokeiso.co.jp
· East Japan Headquarters
Phone : 03-3434-0441(KEY)
Fax : 03-3434-0455

https://www.tokyokeiso.co.jp/english/

UCM-04A/06A Ultrasonic Flowmeter for small liquid flow 2017 is listed under these categories

Industrial Supply > Industrial Automation > Valves and Flow Controls

Featured catalog pages of UCM-04A/06A Ultrasonic Flowmeter for small liquid flow 2017

converter integrated type ultrasonic flowmeter ucm®-04a/06a rohs compliance ultrasonic compact meter outline the ucm-04a/06a is the converter integrated type ultrasonic flowmeter for small flow that offers precise and stable flow measurement for ultra-pure water and chemicals a compact body with a detector and converter saves installation space the 7-segment leds and clear bar graph indication on the front panel allows easy reading in the field the wetted parts are consisting of the molded pfa specified for semiconductor industries the simple and clean construction without any moving parts and without sealing pockets where liquids stagnate makes the ucm-04a/06a an ideal choice for the clean process such as the semiconductor plant the flowmeter has the inlet and outlet tubes of standard dimensions suitable for various pfa fittings in the services where only flow monitor has been simply used so far the ucm-04a/06a can be applied without difficulties features ❏ integration of

ucm®-04a/06a converter integrated type ultrasonic flowmeter model code construction and function ● ● ● ● ● construction ambient temperature humidity mounting communication equivalent to ip64 indoors use 0 to 50°c less than 85 rh and no condensation panel mount modbus protocol rs-485 half duplex asynchronous baud rate 19200 bps multi drop max 32 ✽ addresses are set by configuration software ucm –□□ a –□□□ –□ 1 □□ □ tube 04 inside diameter 06 002 flow range connection table power supply analog output alarm output communication polarity color 24v dc white red dots – 0v dc white black dots dc 24v pink red dots – dc 24v pink black dots dc 24v orange red dots – dc 24v orange black dots dc 24v yellow red dots – dc 24v yellow black dots □ flow range 0 to 8l/min 0 to 1200ml/min 005 0 to 1500ml/min 010 0 to 1000ml/min 020 0 to

ucm®-04a/06a converter integrated type ultrasonic flowmeter separate type sp model code converter specification ● ucm materials –□□ a –□□□ detector size materials flow range heat resistance abs case fluorocarbon rubber cable gland 0 to 1200ml/min 005 0 to 1500ml/min 010 0 to 1000ml/min 020 0 to 2000ml/min cable length 5m standard 10m 10 4 to 20ma 4 analog output type the integrated type always 1 05 pvdf ✽ other materials not mentioned above are the same as 0 to 3000ml/min 1 fixed code cable sheath ptfe for detector specification 002 030 cable sheath pvc jacket □ ucuf–04m [part materials parts –1 □□ □ –sp 04 0 to 20ma 0 always –sp –sp fixed code vacant none special requirement /z yes ✽ only the detector type ucuf-04m suitable for separate type sp is applied ✽ only smb connector with jacket is available for connector type ✽ add z at the bottom of code if

ucm®-04a/06a converter integrated type ultrasonic flowmeter detector specification [ucuf-04m ucm version ● materials ● [part materials pressure loss of water kpa c×q2 materials kpa c×q2 body pfa c pressure loss coefficient tube pfa q flow rate l/min parts wetted parts pressure loss sensor cover pp model c cable fitting pp ucuf-04m 4.5 cable sheath ptfe sensor cap pfa fixing bands pfa jacket pvdf ✽ other materials not mentioned above are the same as the integrated type model code ucuf –□□ m –□ □ □ 04 nominal size specification ✽ standard cable length is 5m the extension cable is available up to 30m 4mm shape cable outlet direction u u tube standard z z type ✽ only smb connector with jacket is available for the connection with the ucm separate type n same as tube outlet side standard w other sides of in/out tube outlets ✽ add z at the bottom of code if any other requirements are requested writing

ucm®-04a/06a converter integrated type ultrasonic flowmeter ucuf-04m-uw ucuf-04m-zw d d in out in ∅20 ∅20 100 100 out 2-∅4 fastening holes rotatable 80±1 96±1 80±1 134 96±1 2-∅4 fastening holes rotatable in out 134 in jacket jacket out smb connector smb connector model connection tube size ucuf-04m-□□ ∅1/4 dimensions mm d d mass g excluding cable 6.35 4.35 60 d d notes on installation ❏ avoid the fluids containing bubbles the bubbles cause adverse affects for precise measurement ❏ the detector and pipe are fully occupied with liquid you may install the meter in either piping horizontally vertically or slantwise but install the bottom face of the detector tube vertically arrange the piping so that liquid inside meter is easily drained ❏ install the flow control valve downstream of meter if required to avoid adverse effects caused by the bubbles generated at downstream of control valve ❏ install the detector