the time of the end the different features of the brochure 12 volt 5 watt light and 21 watt light 30 30 stock h and r 30 30 remote control remote switch ac motor speed controller stainless steel filter housing low energy light bulbs 6 volt remote on off switches electronic speed control control unit uses stainless steel filter housing dc to dc motor control examples of l types of selling out of scope of supply ball bearing using in high temperature voltage control at specific level heated towel rails single gang j box momentary push switch single gang boxes bs en iso thermal overload protection shaded pole motor flat roofs capping contactor motor wiring single phase 3 speed shaded pole motor 24v dc power supply timer brown white brown compact air handling units 24v dc power supply 30 amp rotary switch 12 volt dc fan motor 12 watts 12 volt dc fan fan speed controller anti vibration mount fan speed control 2 gang electrical box 1 gang electrical box declaration of conformity quick release catch 12 volt dc transformer 12 volt dc motor fan variable speed control 12 volt dc fan motor wired remote control dc motor speed controller filter stainless steel mesh replacement air filters 12 volt dc timer fan speed adjustment 3 phase motor speed control unit fan thermal speed control dc variable speed controler three speed fan ac motor wiring

Specification Brochure 2016 is listed under these categories

Home & Garden > Heating Cooling & Air

Featured catalog pages of Specification Brochure 2016

compliant energy related products directive erp as part of the ongoing drive for energy efficiency within europe as of january 2016 ventilation devices over 30 watts come under the scope of the energy related products directive the legislation sets minimum performance criteria across a range of fans and ventilation devices under two sets of legislation ‘residential’ ventilation and ‘non-residential’ ventilation mvhr and mev products these products do come into the scope of the legislation and will carry an energy label there are some minimum energy efficiency requirements as well as the requirement for a summer bypass on heat recovery models a small number of our products have been updated to ensure they meet these requirements the literature on individual products has been updated and can be found on the vent-axia website the following product however has been discontinued • as a result of the legislation we have reviewed our products and where

lo-carbon multivent mvdc-ms/msh dmev mev piv systems mev unit features benefits • best in class specific fan power • reduces your carbon footprint • recognised in sap appendix q • fitted with four extract 125 or 100mm diameter spigots allowing quick connection to ducts models stock ref 437634 443298 mvdc-ms mvdc-msh £trade 346.30 374.11 configuration flow rate sfp w/l/s option of wall ceiling and loft mounting k+1 21 0.16 improved controllability k+2 29 0.15 switched live boost connection k+3 37 0.17 • fully variable normal and boost speeds k+4 45 0.20 • ultra quiet acoustically lined for low noise levels k+5 53 0.24 k+6 61 0.28 • • • with growing concerns about accurate ventilation of properties the lo-carbon multivent mvdc range offers the option of ‘close control’ both in the residential and the commercial sectors with a dc motor the multi speed lo-carbon multivent is one of the most efficient central extract

lo-carbon sentinel kinetic® horizontal performance 200z/zp/zmh model fan speeds are fully adjustable within the performance range 200z/zmh 200zp 600 550 500 500 450 400 300 static pressure pa static pressure pa 400 100 200 60 100 350 300 100 250 80 200 150 60 100 40 40 50 20 0 20 0 volume l/s 0 volume m3/hr 0 10 20 50 30 100 40 150 50 60 200 70 80 250 volume l/s 0 volume m3/hr 0 5 10 15 20 25 30 35 40 45 300 50 100 150 sound data 200z/zmh model flow l/s 25 39 51 60 flow 20 40 60 100 test mode 63 125 250 500 1k 2k 4k 8k dba at 3m supply 50.3 54 50.1 45.5 37 36 27.5 31.1 30.0 26.3 extract 47.2 47.7 46.6 41.8 30.7 27.9 24.6 30.5 breakout 48.8 55.8 51.2 43.8 32.4 29.0 25.4 30.8 26.8 supply 52.7 61.7 60.1 61.8 47.4 45.1 38.1 40.1 42.7 extract 50.7 55.4 55.0 51.5 37.5 34.6 25.9 30.7 33.9 breakout 53.7 60.1 61.1 50.7 40.2 35.8 27.1 30.3 34.0 supply 52.8 64.5 66.7 59.4 51.1 51.1 42.9 39.3 44.0 extract 50.6 59.0 62.1 57.1 43.7 40.0 29.0 31.6 39.7 breakout 55.1 64.4 66.8 57.5 47.0 41.4

commercial range performance curve 500 450 400 static pressure pa 350 300 250 200 150 100 1 50 0 5 4 2 7 6 3 0 50 100 100 0 150 200 volume 500 300 700 250 300 900 l/s 350 3 1300 m /h 1100 performance data curve nominal dia ref r.p.m 0 25 50 100 150 l/s pa 200 250 s.c f.l.c dba watts amps amps 100 1 2740 59 56 52 46 39 31 at 3m 21 83 0.85 0.34 125 2 2410 78 73 69 60 50 39 35 27 86 0.85 0.34 35 300 350 400 150 3 2520 137 130 122 106 89 73 57 39 100 1.10 0.43 45 160 4 2520 137 130 122 106 89 73 57 39 100 1.10 0.43 45 200 5 2620 234 224 214 194 177 159 138 119 100 82 150 1.52 0.68 47 250 6 2720 290 283 270 250 234 216 197 177 156 124 185 1.60 0.77 48 315 7 2720 339 329 313 274 244 218 191 161 131 98 182 1.57 0.75 51 acoustic sound power level dba stock ref dba 63 125 250 500 1k 2k 4k 8k @3m stock ref 63 125 250 500 1k 2k 4k 8k @3m acp10012 inlet 81 84 75 68 61 52 46 40 51 acp20012 inlet 80 79 74 76 67 65 66 60 57 acp10012 outlet 82 84 77 68 61 52 49 43 52 acp20012 outlet 79 79 74 71 69

accessories controls accessories controllers res ps sb.indd 167 06/01/2016

long case axial fans lca performance curves lca45 3 phase 2 pole 1 10° 1 12° 1 14° 1 16° 1 18° 1 20° 22° 1 1 24° 1 26° 1 28° 1 30° 1 32° performance guide 3 phase m3/s at pa ip curve dia stock ref poles rpm rating ref 0 450 lca453210 2 2880 ip55 1 10° 1.72 1.62 1.51 450 lca453212 2 2880 ip55 12° 1 1.89 1.79 1.68 100 200 motor dba 400 500 600 700 kw @3m 1.37 1.17 0.89 0.56 0.25 1.1 74 1.54 1.34 1.08 0.73 0.37 1.1 73 0.9 0.5 1.5 72 300 450 lca453214 2 2880 ip55 1 14° 2.08 1.97 1.85 1.7 1.51 1.26 450 lca453216 2 2880 ip55 16° 1 2.27 2.16 2.03 1.88 1.69 1.43 450 lca453218 2 2880 ip55 18° 1 2.47 2.35 2.21 2.05 1.86 1.59 450 lca453220 2 2880 ip55 1 20° 2.65 2.53 2.38 2.21 2.01 450 lca453222 2 2880 ip55 1 22° 2.82 2.69 2.53 2.35 2.14 450 lca453224 2 2880 ip55 1 24° 2.99 2.84 2.67 2.48 2.26 450 lca453226 2 2880 ip55 1 26° 3.15 2.99 2.82 2.61 450 lca453228 2 2880 ip55 1 28° 3.32 3.15 2.96 2.75 450 lca453230 2 2880 ip55 1

plate case fans performance curve bifa50 1 3 phase 4 pole 1 10° 1 12° 1 14° 1 16° 1 18° 1 20° 1 22° 1 24° 1 26° 1 28° 1 30° 1 32° 1 34° 1 36° 1 38° 1 40° performance guide 1 phase 3 phase ip curve dia stock ref stock ref poles rpm rating ref 500 bifa501410 bifa503410 4 1400 ip55 500 bifa501412 bifa503412 4 1400 ip55 500 bifa501414 bifa503414 4 1400 500 bifa501416 bifa503416 4 500 bifa501418 bifa503418 4 500 bifa501420 bifa503420 500 bifa501422 500 bifa501424 500 500 m3/s at pa motor dba 0 40 80 120 160 kw @3m 1 10° 1.14 1.01 0.84 0.58 0.18 0.25 58 1 12° 1.28 1.15 0.97 0.72 0.3 0.25 58 ip55 1 14° 1.42 1.28 1.1 0.85 0.42 0.25 58 1400 ip55 1 16° 1.56 1.41 1.22 0.97 0.25 58 1400 ip55 1 18° 1.69 1.53 1.34 1.09 0.25 58 4 1400 ip55 1 20° 1.82 1.65 1.45 1.19 0.37 58 bifa503422 4 1400 ip55 1 22° 1.93 1.76 1.56 1.29 0.37 58 bifa503424 4 1400 ip55 1 24° 2.04 1.87 1.66 1.39 0.37 58 bifa501426 bifa503426 4 1400 ip55 1

in-line fans models accessories speed controller electronic auto transfor starter overload stock ref stock ref stock ref stock ref stock ref electric heaters stock ref slp100 sp5001 spm5020 444744 444699 10531100t1 slp125 sp5001 spm5020 444744 444699 10531125t1 slp150 sp5001 spm5020 444744 444699 10531150t1 slp200 sp5001 spm5020 444744 444699 10531200t1 slp250 sp5001 spm5020 444744 444700 10531250t1 slp315 sp5001 spm5020 444744 444702 10531315t1 attenuators inlet discharge stock ref stock ref stock ref wall terminal stock ref slp100 slsi100/1 slsd100/1 sa100/280 slp125 slsi125/1 slsd125/1 sa125/280 slp150 slsi150/1 slsd150/1 sa150/280 slp200 slsi200/1 slsd200/1 sa200/280 slp250 slsi250/1 slsd250/1 sa250/280 slp315 slsi315/1 slsd315/1 sa315/280 louvre flexible roof terminal shutter connections panel filters spare panel filters back draught shutters stock ref stock ref stock ref stock ref stock ref stock ref stock ref slp100 wrc100 ls250 flx100 slpf100 filtersslp100 bds100 slp125

sentinel d-box twin fan features and benefits impellers performance/sound all sentinel units feature a low energy class extensively tested to bs848 parts 1 2 published 1 ec/dc external rotor motor and backward dba figures are free field sound pressure levels sentinel demand ventilation fan controller with lockable isolator curved impeller assembly specifically chosen for at 3m with spherical propagation at reference performance and non-overloading characteristics level of 2x10-5 pa the inlet/outlet sound power • latest energy saving ec/dc motors the assembly is dynamically balanced to din iso level spectra figures are db with a reference of • internal or external models ipx2 or ipx5 1940 grade 6.3 duct size 500mm rated ip54 10–12 watts • manufactured controlled to bs en iso 9001 ball bearings are greased for life insulation is • performance tested to bs848 part 1 2 • duct sizes 100 – 500mm • performance airflow 0.01 to 1.2m3/s

roof fans fan dimensions mm fan size details for purlin mounting abcd weight kg 250 500 500 280 90 16 315 700 680 410 83 16 355 400 800 780 480 83 24/27 450 950 930 575 103 45 500 560 1230 1055 630 103 48 64 details for kerb mounting manufactured from 1.5mm pre-galv mild steel g max roof pitch 30Ëš fan size fan size abcdef 315 625 90 355 400 725 90 450 890 70 500 560 1030 75 240 765 400 653 400 240 865 500 753 500 250 990 650 878 650 250 1140 760 1028 790 w www.vent-axia.com/industrial roof fan range sb.indd 371 g a b 250 500 500 c d e 280 90 16 315 700 680 410 83 16 355 400 500 700 570 83 450 650 850 690 103 500 560 790 990 842 100 103 371 06/01/2016

accessories controls optional air flow direction 1 way 2 way 2 way 2 way neck adaptors used to connect flexible ducting directly to 4-way diffusers for intake/extract applications 4 way 3 way 3 way 3 way high ceilings/heating spot throw stock ref diffuser size duct Ø 10547150 225mm 150mm 10547200 225mm 200mm 10547250 300mm 250mm 10547300 350mm 315mm 10547400 400mm 400mm 10548400 450mm 400mm 10548000 500mm 315/400mm 4 way dimensions mm cool air distribution bØ sizes 150 200 250 300 are supplied with a volume control flap mounting types type 1 type 2 w www.vent-axia.com/accessories accessories&controls non res sb.indd 411 stock duct ref dia a Øb c 10547150 150 235 145 115 10547200 200 235 195 115 10547250 250 305 245 115 10547300 300/315 355 295 110 10547400 400 407 400 90 10548400 400 459 400 92 10548000 315/400 500 315/400 168 max 411 11/01/2016