mil-spec aircraft cable mil-c-7078c aircraft cables the mil-c- ... or slash sheets covering electrical cable typically used in aerospace ... applications the cables may be ordered unshielded unjacketed ... just a shield or shielded and jacketed each slash sheet will ... what type insulation and outer covering cable constructions ordered to mil-c-7078 ... /x yy z number of basic wires in cable size of individual wires number of ... /2 mca-m7078/3 mca-m7078/4 mca-m7078/5 basic basic basic basic wires wires ... 105°c105°c105°cmil-c-27500 aircraft cables the mil-27500 covers the requirement ... of letters and digits to describe the cable build-up the cable con types unjacketed ... laid with an overall outer jacket cable designation method m27500cable ...
091028 connectors voltage wires x size cable reference sheath wire drop material ... colour colour cable code caduta fili x sezione materiale ... pvc lifyy bk 9005 a 429 4,0 0,09 2 x 0,50 pur pvc liyy11y bk 9005 a 409 4,0 0,09 ... 2 x 0,50 pvc iec 60332-3a gy 7035 a 412 4,0 0,09 ... 2 x 0,50 pvc liyy bk 9005 a 516 4,0 0,06 2 x 0,75 pur pvc liyy11y bk ... 9005 a 503 4,0 0,06 2 x 0,75 pvc liyy bk 9005 a ... 414 4,0 0,09 2+1 x 0,50 pvc liyy bk 9005 a 145 3,2 0,32 3 x 0, ... °c ul-csa bk 9005 a 441 4,0 0,09 3 x 0,50 pur pvc liyy11y bk 9005 a 411 4,0 0,09 ... 3 x 0,50 pvc liyy bk 9005 a 507 4,0 0,06 3 x 0,75 pvc liyy bk 9005 a ... 422 4,0 0,09 3+1 x 0,50 pvc iec 60332-3a gy 7035 a 376 4,0 0,13 ...
6
091028 connectors voltage wires x size cable reference sheath wire drop material ... colour colour cable code caduta fili x sezione materiale ... ral b1 b2 b3 a2 b4 407 4,0 0,09 [2 x 0,50]s pvc iec 60332-3a gy 7035 c 546 4,0 0,06 ... 80°c ul-csa bk 9005 a 261 4,0 0,18 [5 x 0,25]s pur halogenfree 300v 80°c ul- ... csa bk 9005 a 368 4,0 0,13 [5 x 0,34]s pur halogenfree 300v 80°c ul- ... csa bk 9005 a 357 4,0 0,13 [5 x 0,34]s pvc 300v 80°c ul-csa bk 9005 a ... pvc 300v 80°c ul-csa bk 9005 c b1 other cables are available on request such as ... irradiated pur teflon shieldedcables etc see cable catalogue altri cavi ... norms allow maximum values drop on the cable from 3 to 5 of rated voltage for ... massimi di caduta sul cavo dal 3 al 5 della tensione nominale per il calcolo ...
091028 connectors voltage wires x size cable reference sheath wire drop material ... colour colour cable code caduta fili x sezione materiale ... x 0,25 pvc lifyy bk 9005 a 241 4,0 0,18 5 x 0,25 pur pvc lifyy11y bk 9005 a 221 4 ... ,0 0,18 5 x 0,25 pvc iec 60332-3a gy 7035 a 201 4 ... ,0 0,18 5 x 0,25 pvc lifyy bk 9005 a b1 other ... cables are available on request such as ... irradiated pur teflon shieldedcables etc see cable catalogue altri cavi ... norms allow maximum values drop on the cable from 3 to 5 of rated voltage for ... massimi di caduta sul cavo dal 3 al 5 della tensione nominale per il calcolo ... tecniche b3 example 3 three conductors 4+1 four wires green/yellow ground ... bn bu bk wh 4 wires bn bu bk wh gy 5 wires colore fili a bn bu 2 fili bn ...
6
091028 connectors voltage wires x size cable reference sheath wire drop material ... colour colour cable code caduta fili x sezione materiale ... x 0,25 pvc lifyy bk 9005 a 241 4,0 0,18 5 x 0,25 pur pvc lifyy11y bk 9005 a 221 4 ... ,0 0,18 5 x 0,25 pvc iec 60332-3a gy 7035 a 201 4 ... ,0 0,18 5 x 0,25 pvc lifyy bk 9005 a b1 other ... cables are available on request such as ... irradiated pur teflon shieldedcables etc see cable catalogue altri cavi ... norms allow maximum values drop on the cable from 3 to 5 of rated voltage for ... massimi di caduta sul cavo dal 3 al 5 della tensione nominale per il calcolo ... tecniche b3 example 3 three conductors 4+1 four wires green/yellow ground ... bn bu bk wh 4 wires bn bu bk wh gy 5 wires colore fili a bn bu 2 fili bn ...
coax cable speaker wire belden coaxial cables continued due to extraordinary copper ... market price fluctuations cable and wire prices are subject to change ... belden coaxial cables continued rg59 type security coaxial ... cable 20 awg solid bare copper conductor · 95 bare copper braid shield · nominal ... ® flame retardant flooding compound · shielded or flooded for use in underground ducts ... black part no product no description 1 5 10 precision video cable for analog and ... pvc jacket · nominal capacitance 53.1pf/m · nominal impedance 75 · duofoil® +95 ... .275 part no product no description 1 5 10 734100cg 734156cg734155cg 447267cg ... 447275cg 1694a-100-10 1694a-500-10 1694a-1000-10 1694a-1000-06m 1694a-1000 ... -08m 100 reel black $66.49 500 reel black 234.89 1000 reel black ...
3
copper market price fluctuations cable and wire prices are subject to change ... paired cable belden paired cables belden cable products are manufactured ... many different types of systems paired cables allow balanced signal transmission ... higher data speeds than other multi-conductorcables for our complete line of belden ... wire · overall 100 beldfoil® shield for shieldedcables high-temperature control ... instrumentation cables and computer cables 24 awg stranded 7 x 32 shielded with 24 ... audio control and instrumentation cables non-plenum cont d 22 awg stranded 7 x ... 30 shielded with 22 awg stranded tc drain wire · ... no product no no of pairs description 1 5 10 9502 series part no product no 9503 ... no of pairs description 1 9504 series 5 10 732710cg 732718cg 732726cg 734074cg ...
cables cavi ma-hk ma-lk no toxic low smoke ... halogen free iec 60092 description conductor insulation of xlpe sheath shf1 ... iec 60332-1 test with single vertical cable flame applied for 60 seconds at 55 mm ... 2000 v note to table a example 3 three conductors 2+1 two wires yellow/green earth b ... per 60 secondi alla distanza di 55 mm conforme a norme iec 60092-376 ... -03ga5ma-hk96-03xa5ma-hk96-04ga50,75586587581583 687 690 xlpe xlpe xlpe xlpe ... 9005 bk 9005 bk 9005 bk 9005 aaaaaaaaa 555555555 -25 80 -25 80 -25 80 ... halogen free iec 60332-3c description conductor insulation of polyolefin sheath of ... iec 60332-3c test with vertical cable bundle flame applied for 20 minutes at ...
2
cables cavi mb-hk mb-lk no toxic low smoke ... halogen free iec 60092 shielded description conductor insulation of ... iec 60332-1 test with single vertical cable flame applied for 60 seconds at 55 mm ... 2000 v note to table a example 3 three conductors 2+1 two wires yellow/green earth s ... per 60 secondi alla distanza di 55 mm conforme a norme iec 60092-376 ... -03ga5mb-hk96-03xa5mb-hk96-04ga50,75588589 688 689 xlpe xlpe xlpe xlpe xlpe ... 9005 bk 9005 bk 9005 bk 9005 aaaaaaaa 55555555 -25 80 -25 80 -25 80 - ... low smoke halogen free iec 60332-3c shielded description conductor insulation of ... iec 60332-3c test with vertical cable bundle flame applied for 20 minutes at ...
6 AUDIO Noise-Free Technology Cables Are the First Fully ShieldedCable and ... . Part No. Length Pkg. NFT1.5 1-1/2 ft Pkgd NFT3 3 ft Pkgd NFT6 6 ft ... Frequency (RF) Interference Double Shielded with 100% Oxygen Free Copper (OFC) 24K ... Posi-Grip RCA Type Plugs High Flex PVC Cable Jacket Distinctive Metal Blue Color ... inch Pkgd NFT NOISE-FREE TECHNOLOGY Y CABLE ADAPTERS BFS TECHNOLOGY BALANCE ... Balanced Frequency Super Premium Stereo Cables Interconnect Various Audio Inputs/ ... (RF) Noise 20-AWG Stranded Center Conductor with Oxygen Free Copper For Less ...
41
VIDEO COAX CABLE cont. CAMERA CABLES USB 2.0 DIGITAL CAMERA CABLES BULK ... COAXIAL CABLE Rt Angle RG59/U Premium Video Cable " ... Straight "F" Type Plug 75 Ohm Coaxial Cable 24K Gold Plated "F" Connectors ... Stranded Center Conductor for Optimum Signal Strength and Cable ... 75 Ohm Coaxial Output from Antenna, Cable, VCR, Splitter, etc. to 75 Ohm Coaxial ... 12 ft Blue Pkgd Flat Window Coaxial Cable Designed to Feed the Video Signal ... Allowed or Wanted Flat, 75 Ohm Coaxial Cable Female F Connector on Each End of ... Cable Part No. Length Color Pkg. 120108 8 ... to RCA Male Plug High Quality TV/VCR cable Made of Low Loss RG59Cable Molded ... Bulk RCA Male Plug to BNC Connector Shielded Low Loss RG59 Coax Cable Molded Black ...
the same size non-combination stranded conductor compact stranded conductor a ... or conventional concentric conductor manufactured to a specified diameter ... the nominal diameter of a non-compact conductor of the same cross-sectional area ... composite conductor a conductor consisting if two or more types of wire ... and electrically as a single conductor compound filled splice joints in ... temperatures compressed stranded conductor a conventional concentric conductor ... the nominal diameter of a noncompressed conductor of the same cross-sectional area ... around the core to form a single conductor conductance the real part of ... resistivity it has units of mhos/meter conductor a material suitable for carrying an ... types are as follows concentric-lay conductor conductor constructed with a central ...
110
transmission speed up to 2mbps longer cable lengths and 10 additional functions rs- ... wire moistureresistant 60c semi-rigid cable generally refers to type mi or type ... separator pertaining to wire and cable a layer of insulating material such as ... mylar etc which is placed between a conductor and its dielectric between a cable ... various components of a multiple-conductorcable it can be utilized to improve ... an insulated device to facilitate cable connections and separations serial ... lan seu service entrance underground cable 300 volts sew sewf silicone rubber ... fi xture wire solid or 7 strand conductor 200c sff same as sf except flexible ... noted for high heat resistance single cable a one-cable system in broadband lans ... thermoplastic or rubberinsulated conductors with overall thermoplastic jacket 300v ...
u tiflex miniature low loss cable assemblies these general purpose ... microwave miniature cables have been designed to offer superior ... a cost-effective alternative when an rg cable cannot perform to your system needs or ... when a semi-rigid cable is too cumbersome the utiflex miniature ... cables are available with a large selection of ... type outer diameter inch mm center conductor type weight grams/ft meter minimum bend ... ugn070d 0.070 1.78 solid 3 9.84 0.10 2.54 uff092d 0.092 2.34 solid 5 16.41 0.13 3 ... .18 uff092f 0.092 2.34 stranded 5 16.41 0.13 3.18 electrical ... vs temperature power handling vswr cable wrapped around a 2 inch diameter ... mandrel 50 dc-18 77 26.2 86.0 100 0.351.15 1.12 ... 3.67 1.52 4.99 2º 4º 50 dc-18 77 26.2 86.0 100 see figure on ...
12
u tiflex low loss cable assemblies utiflex low loss cable ... the complete high performance microwave cable they have outstanding mechanical ... phase stability or swr utiflex low loss cable assemblies are extremely versatile ... type outer diameter inch mm center conductor type weight grams/ft meter minimum bend ... ufa125a0.125 3.18 solid 8 26.2 0.20 5.08 10,000 ufa147a 0.147 3.73 solid 11 36.1 ... 11 36.1 0.256.35 100,000 ufa210a 0.210 5.33 solid 20 65.6 0.38 9.65 10,000 ufa210b ... 0.210 5.33 stranded 20 65.6 0.38 9.65 100,000 ... loss db/ft meter 1 ghz 10 ghz 18 ghz 26.5 ghz 40 ghz 50 ghz phase stability vs ... vs temperature power handling vswr cable wrapped around a 2 inch diameter ... mandrel 50dc-50 77 26.2 86.0 100 0.15 0.49 0.49 1.61 0 ...
overload 19 r 7 30 alarm 2 2lt r 16 36 5sol 2 set points name 1 2 3 4 5 6 7 8 9 10 ... state and national codes use copper conductors only control wiring 14awg with max 15a ... overload turn compressor switch off for 5 seconds customer control contacts must ... be wired between terminals 8&13 if 0-5 vdc cwr is used set setpoint 16b to ... reset desired at +5vdc input caution do not supply over 5.0vdc ... to 6ai shieldedcable is recommended for customer supplied ... contact rating is 10a at 125 vac and 5a at 250 vac 1/2 hp 678910 12 13 if 0-5 ... 16a to the desired demand limit at +5 vdc input there is no demand limiting ... 0 vdc input caution do not supply over 5.0 vdc to 7ai 5m is used in the extended ...
53
not furnished ai board #2 2aib +5 ai14 6 42 5465 compressor starts ... option 1sc elapsed time meter option 42 54 1etm modem option furnished not ... w #1 mtr overload 41 r 74 alarm 2 2lt r 50 #2 mtr overload 53 r #3 mtr overload 64 ... r 26 5cr 2 24vac 5cr 4t 38 62 27 6cr 2 114 10 116 117 115vac ... supplied 6mtr 4mtr comp #1 tx valve 5mtr comp #2 tx valve comp #3 tx valve h0t ... not furnished to mcb j2 ribbon cable ribbon cable to mcb j2 digital output ... 149 24sn 14sol circuit #2 20 12vac 21 5c gnd 20 27cp 5no15025sn15sol circuit ... state and national codes use copper conductors only control wiring 14awg with max 15a ... be wired between terminals 10 and 33 shieldedcable is recommended for flow switch ... contact rating is 10a at 125vac and 5a at 250vac 1/2hp if 0-5 vdc cwr is used ...
copper market price fluctuations cable and wire prices are subject to change ... paired cable belden paired cables belden cable products are manufactured ... many different types of systems paired cables allow balanced signal transmission ... higher data speeds than other multi-conductorcables for our complete line of belden ... wire · overall 100 beldfoil® shield for shieldedcables high-temperature control ... instrumentation cables and computer cables 24 awg stranded 7 x 32 shielded with 24 ... audio control and instrumentation cables non-plenum cont d 22 awg stranded 7 x ... 30 shielded with 22 awg stranded tc drain wire · ... no product no no of pairs description 1 5 10 9502 series part no product no 9503 ... no of pairs description 1 9504 series 5 10 732710cg 732718cg 732726cg 734074cg ...
111
copper market price fluctuations cable and wire prices are subject to change ... multi-conductorcable hook-up wire solid hook-up wire 22 ... awg · temp range -55°c to +105°c · passes ul vw-1 flame test ... no cross ref no color 1000 ft wire cable568641cgmulti-conductorunshielded ... communications control cable · 22 awg 7 x 30 stranded tinned copper ... 2576 type cm · pvc jacket · gray · 2 conductor568691cgmulti-conductor foil shield ... tinned copper · rating 300v 75°c · 2 conductor · pe insulation · pvc jacket gray ... 568827cg xtra guard® i multi-conductorunshieldedcable · 24/20/18/16 awg ... pvc jacket · rating 300v -20°c to 80°c 568747cg0.050 centers flat ribbon cable · ... 2651 · nominal capacitance 14pf/ft · 9 conductors · gray · nominal impedance 105 · ...
: Approximately 40 dB range Impedance: 5000 ohms max., recommended load of 100 ohms ... or configured with 4 pin (DX1) or 5 pin (DX2) DIN. Cable: Five conductor ( ... one conductorshielded) coiled cord that extends to 2.3 m (7 1 ... strain relief bushing protects against cable breakage at microphone housing. Housing ... ) Size: 86 mm (3 3/8") high x 60.5 mm (2 3/8") wide x 27 mm (1 1/16") deep ... Weight: 220 grams (7 3/4 oz.) 59.95 US Page 152/525 ...
160
: Approximately 40 dB range Impedance: 5000 ohms max., recommended load of 100 ohms ... or configured with 4 pin (DX1) or 5 pin (DX2) DIN. Cable: Five conductor ( ... one conductorshielded) coiled cord that extends to 2.3 m (7 1 ... strain relief bushing protects against cable breakage at microphone housing. Housing ... ) Size: 86 mm (3 3/8") high x 60.5 mm (2 3/8") wide x 27 mm (1 1/16") deep ... Weight: 220 grams (7 3/4 oz.) 59.95 US Page 160/525 ...
wire cable solutions outside plant cable outside voice and data ovd products ... specify general cable outside plant wire and cable and be ... pair sizes in air-core and filled-core cables and specialty wire products for aerial ... and direct-buried applications general cable s plastic-insulated filled-core cable ... bellcore specifications plus general cable ovd wire and cable is noted for its ... · self-supporting one-pair parallel conductor drop wire intended for aerial service ... to the subscriber catalog a adp-2cp18.5-z k-gcc description pvc-insulated drop ... 22 or 24 insert reel length ft 2.5 or 5 description double-jacketed buried ... 22 or 24 insert reel length ft 2.5 or 5 description double-jacketed buried ... provider solutions guide 800-825-5517 7 a.m 5 p.m ct www.graybar.com 68 ...
71
central office cablecable and wire exchangemax cable and wire ... avaya s twisted-pair and coaxial cables are some of the smallest in the ... industry exchangemax coaxial cableshieldedunshielded hookup wire and twisted-pair ... cable products have the optimum combination ... code pair/awg 25/24 28/24 30/24 32/24 50/24 4/26 6/26 12/26 16/26 20/26 25/26 28 ... /26 32/26 50/26 100/26 6/22 12/22 16/22 25/22 30/22 ... 32/22 28/22 20/22 56/22 12/24 25/24 packaging rvar rvar rvar ... rvar rvar rvar rvar rvar rvar r1000 a shielded twisted-pair cable a 108236662 1161a ... 1107a b catalog product code pair p or conductor c awg 006 012 2p/24 6p/24 25p/24 ... /24 100p/24 25p/26 100p/26 28p/24 4p/24 50p/24 100p/24 32p/26 100p/26 2c/22 2c/22 ...
remote am antenna 2 raa1 connection cable complete 2 seven conductor ribbon cable ... 1 six conductor ribbon cable 1 four conductor ribbon cable 1 tm1 serial number label ... connect the shield and two leads of a shielded 2 conductorcable to the supplied 5 pin ... if there is need to make-up a longer cable use a two conductorshielded wire and ... the connectors below 5 pinterminal connector 1 n/c red 2 n/c 3 ... red wiire 1 4 black wire 5 green wire shield black green 5 am/fm ... tuner module tuner module connecting cables tm1 serial number label figure 1 anti- ... 1 red wire 2 black wire 3 n/c 4 n/c 5 n/c 6 jumper from pin 7 7 green wire ... raa1 remote am antenna raa1 connection cable figure 2 3 ...
b.g micro 555 n 5th street suite 125 garland tx 75040 ... -205-9447 vga male to female extension cable 6 foot db-25 male/female cab2038 $1.95 ... 9 female/female 6 ft vga high end video cable this high end cab2067 $1.95 video ... cable has a high density 15 pin d-sub for ... video card on one end and 5 bnc connectors on the other it will ... for the 3-bnc type and the 4-bnc type cable is 6 foot long and will handle red ... sync and horizontal sync cab1076 12.50db15hd male to 2 db15hd female y ... cable cab2082 $5.95 s video y cable s video male to 2 s video female ... our web page http www.bgmicro.com vga cables/connectors null modem cables s video y ... use db15hd male to 2 db15hd female y cable this cigarette lighter cab2082 $5.95 ...
catalog battery accessories taylor cable products is an oem and performance ... ignition spark plug wire battery cable wiring harnesses magnetos and other ... and hardware kit above w/16 2-gauge cable kit single trunk mount kit provides ... track proven to add up to an additional 5hp when properly grounding engines by ... to starter and battery to ground/block cable heat shrink sleeve tubing and all ... hardware part no 21530 with 2 gauge cable part no 1041 1042 1044 new header wrap ... protector kit part no 2537 diamond back shielded battery cables heavy duty 4 gauge 100 ... copper conductor battery cables with solid brass terminals lengths ... those not listed top 17 24 34 38 5365 part no 20017 20024 20034 20038 ... 20136 20142 20149 fire sleeving protect cables hoses tubing and wires from heat ...
u tiflex ultralight cable assemblies utiflex ultralight cable ... best radiation resistance in a flexible cable construction the cables utilize dupont ... loaded tefzel® jacket if required cable assemblies are manufactured in a class ... type outer diameter inch mm center conductor type weight grams/ft meter minimum bend ... 0.088 2.24 solid 3.3 10.8 0.256.355,000uhj205a0.2055.21 solid 15.0 49.2 0.50 ... 12.70 5,000 uhj311a 0.311 7.90 solid 33.0 108.3 1. ... 2531.755,000 electrical characteristics impedance ... loss db/ft meter 1 ghz 10 ghz 18 ghz 26.5 ghz phase stability vs flexure 10 ghz ... vs temperature power handling vswr cable wrapped around a 2 inch diameter ... mandrel cable wrapped around a 3 inch diameter ... mandrel 50 dc-18 78 25.6 84.0 -100 0.21 0.69 0.67 ...