brass fittings inverted flare a refer to safety information regarding proper ... selection of tubing and tube fittings on page 1 tube o.d thread size ... 16 · assembly instructions 1 cut tubing to desired length make sure all burrs are ... the ends are cut square 2 slide nut on tube threaded end a of nut must face out 3 ... flare end of tube with a 45° flaring tool see page 26 for flare data a measure ... flare diameter b examine flare for excessive thin out c on thin wall ... welded or brazed tubing use double flare to prevent pinch-off and cracked flares ... 4 lubricate threads and assemble to fitting body nut should be turned hand ... apply a one-sixth turn note do not over-torque as it may damage the fittings or split ... the tubing at the flare label set w-8022 adhesive cl-490 non- ...
sae 45° flare refer to safety information regarding proper ... selection of tubing and tube fittings on page 1 a brass fittings ... brass tube o.d thread size-b 1/8 5/16-24 3/16 3/8- ... systems · pressure working pressure up to 2000 psi depending on tube size will ... burst pressure of standard tubing up to 5000 psi with bundy-weld double flared ... and 3500 psi with copper tubing depending on size · vibration ... is required · temperature range -65°f to +250°f 53°c to +121°c range at maximum ... · material ca360 brass · used with copper brass aluminum and steel hydraulic ... tubing that can be flared see page 28-32 for material ... long or short nut good resistance to vibration · conformance listed by ... asme sae and ms military standards · how to order order individually by catalog ...