14 Wood Construction Connectors IMPORTANT ... Strong-Tie Co., Inc. reserves the right to change specifications, designs, and ... or liability for such changes. b. Steel used for each Simpson product is ... selected based on the products steel specifications, including strength, ... , and weldability. Contact factory for steel information on specific products. c. ... , bolts and nails may not be combined to achieve highest load value. 8d (0.131" ... be noted (for example 8dx1 ). Refer to page 16, 17, NDS (National Design ... conditions must be adjusted according to the code. In many cases, Simpson code ... , since the specific gravity of these wood species fall within the specific ... specific gravity for the different wood species as listed by NDS. For your ... drawing is included with the order. Steel specified on the drawings as ", ", and ...
51 Caps Bases BC/BCS Post Caps LCC Lally Column Caps Model No. ... Loads (133 160) 1 W1 W2 L1 L2 H1 H2 Beam Surface Post Surface Post Top Surface ... cap over the lally column and attach to the girder. CODES: See page 12 for Code ... a 3 ply LVL and a 3 "diameter steel column 1. Loads may not be increased ... of the bearing loads using Fc equal to 425 psi for SPF, 625 psi for DF and 700 ... capacity. 3. Loads are for a continuous beam. 4.Spliced conditions must be detailed ... by the Designer to transfer tension loads between spliced ... splice condition load is 6750 lbs per beam side and the lally cap must be evenly ... loaded. 5. To achieve lateral loads, LCC pipe must be ... welded to the column with an fillet weld around ... BCS allows for the connection of 2-2xs to a 4x post or 3-2xs to a 6x post. Double ...